Laserfiche WebLink
*40 RECEIVED <br /> Appendix VI <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://W Wwr 1AT"9H_% <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Junsdictions Within the State of California ENVIRONMENTAL <br /> Authorlty Cited:Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, id(Fft 196 4TYPT <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: YRC 813 Bldg. No.: <br /> Site Address: 1535 E PESCADERO AVE City: TRACY Zip: 95304 <br /> Facility Contact Person: KRIS/ROY Contact Phone No.: 209993-7946 <br /> Make/Madel of Monitoring System: Veeder Root tis 350 Date of Testing/Servicing: 3/8/2013 <br /> B.Inventory of Equipment Tested/Certified <br /> Check <br /> the appropriate boxes to indicate specific eaulpment in serviced: <br /> Tank ID: waste oil near rack-WASTE OIL Tank ID: waste oil near gate-WASTE OIL <br /> P In-Tank Gauging Probe. Model: mag r In-Tank Gauging Probe. Model: <br /> WO Annular Space or Vault Sensor. Model: 303 P Annular Space or Vault Sensor. Model: 303 <br /> PO Piping Sump/Trench Sensor(s). Model: 205 PO Piping Sump/Trench Sensor(s). Model: 205 <br /> F Fill Sump Sensor(s). Model: r Fill Sump Sensor(s). Model: <br /> r Mechanical Line Leak Detector. Model: r Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Model: <br /> JV_ Tank Overfill/High-Level Sensor.Model: flapper r Tank Overfill/High-Level Sensor.Model: flapper <br /> Other(specify equipment type and model in Section E on Pa 2 . Other(specify equipment type and model in Section E on Pae 2). <br /> Tank ID: anti freeze-ANTIFREEZE Tank ID: gear oil-GEAR OIL <br /> P In-Tank Gauging Probe. Model: mag r7o In-Tank Gauging Probe. Model: mag <br /> WO Annular Space or Vault Sensor. Model: 303 r Annular Space or Vault Sensor. Model: 409 <br /> WO Piping Sump/Trench Sensor(s). Model: 205 570 Piping Sump/Trench Sensor(s). Model: 205 <br /> F Fill Sump Sensor(s). Model: r Fill Sump Sensor(s). Model: <br /> r Mechanical Line Leak Detector. Model: r Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Madel: <br /> (✓ Tank Overfill/High-Level Sensor.Model: flapper PO Tank Overfill/High-Level Sensor.Model: flapper <br /> Other(specify equipment type and model in Section E on Page 2). Other(specify equipment type and model in Section E on Pae 2). <br /> Dispenser Dispenser <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: r Dispenser Containment Sensor(s).Model: <br /> r Shear Valve(s). r Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser Dispenser <br /> ID: ID: <br /> • Dispenser Containment Sensor(s).Model: r Dispenser Containment Sensor(s).Model: <br /> • Shear Valve(s). r Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser Dispenser <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: r Dispenser Containment Sensor(s).Model: <br /> F Shear Valve(s). r Shear Valve(s). <br /> F Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> -If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply):r System set- <br /> up r Alarm history report <br /> Technician Name(print): Jarrod Cooke Signature: <br /> Certification No.: B35255 License.No.: 743160 Clas'A' <br /> Testing Company Name: Tanknology Phone No.: (800)8004633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 3/8/2013 <br /> Monitoring System Certification Page 1 of 4 12/07 <br />