My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SACRAMENTO
>
2
>
2300 - Underground Storage Tank Program
>
PR0506730
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2020 11:47:13 PM
Creation date
11/6/2018 11:59:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0506730
PE
2381
FACILITY_ID
FA0007597
FACILITY_NAME
LODI DEPOT
STREET_NUMBER
2
Direction
N
STREET_NAME
SACRAMENTO
STREET_TYPE
ST
City
LODI
Zip
95240
CURRENT_STATUS
02
SITE_LOCATION
2 N SACRAMENTO ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SACRAMENTO\2\PR0506730\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
10/19/2017 3:46:51 PM
QuestysRecordID
3689581
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA :� + <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> „ 1 ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ON SITE <br /> MARK ONLY �( 1 NEW PERMIT ❑ 3 RENEWAL PER ('I <br /> ONE REM ❑ 2 INTERIM PERMIT <br /> ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED / <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: LQ <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS– SPECIFY IF UNKNOWN <br /> S. MANUFACTURED By:: U h <br /> A OWNER'S TANK I.D.a <br /> D. TANK CAPACITY IN GALLONS: <br /> C. DATE INSTALLED(MO/DAY/YEAR) U n�. <br /> iEl <br /> 7CHFMICAtLPRODUCT <br /> AiF—1 <br /> IS MARKED,COMPLETE ITEM C. ❑ 1a REGU M UNLEADED 3 DIESEL ❑ 6 AVIATION GAS <br /> ' 4 OIL B. <br /> C. 1b PREMIUM UNLEADED ❑ 4 GASAHOL ❑ 7 METHANOL <br /> PRODUCT ED <br /> 80 EMPTY ❑ 1c MIOGRADE UNLEA0E0 ❑ 5 JETFUEL ❑ 8 EM 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ 98 OTHER(DE SCRIBE IN ITEM D.BELOW) <br /> C.A.S. <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A B.AND C,AND ALL THAT APPLIES IN BOX AND E <br /> ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR UNER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> A. TYPE OF �r�yy1I ❑ ❑ 99 OTHER <br /> SYSTEM I^J 2 SINGLE WALL 4 SINGLE WALL IN A VAULT <br /> 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B. TANK ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR ❑ 7 RUBBER LINED ❑ 8 UNLINED 95 UNKNOWN ❑ 99 OTHER <br /> LINING OR ❑ 5 GLASS LINING <br /> COATING IS UNING MATERIAL COMPATIBLE WITH 100% METHANOL] YES— NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION 97 NONE 95 UNKNOWN ❑ 99 OTHER <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ <br /> SPILLCONTAINMENT INSTALLED(YEAR) OVE11 LI.—EN <br /> TION EQUIPMENT INSTALLED(YEAR) <br /> E.SPILL AND OVERFILL,etc. DROP TUBE YES_ NO <br /> STRIKER PLATE YES__ NO_ DISPENSER CONTAINMENT YES NO_ <br /> IV,PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> A U i BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> C. MATERIAL AND A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION p U 95 UNKNOWN ❑ A U 99 OTHER 99 OTHER <br /> 1 MEgVMGL ZINE LEAK ❑2 UNE MME ❑3 NWICISURWG INTERSTmAI ❑4 LEAK OEIECTOPEMMONIC E 5 sKumom PUMP <br /> D. LEAK DETECTION ❑ pETEOTOR TEsnND <br /> V.TANK LEAK DETECTION <br /> ❑ VADOZEMONITORING ❑ 4 GAUGING <br /> TANK ❑5 MON MONITOOUND RING <br /> ❑ 6 ANNUAL TANK <br /> INV❑ 1 VISUAL CHECK ❑ 2 FMANUAL IE ATIONORY 3 MONITORING <br /> TESTING <br /> ❑ 7 <br /> MONITORING NUOUINTERSTITIAL ❑ 8 SIR ❑ 9 WEEKLY <br /> MANUAL ❑10 MONTHLY TESTING TANK ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) 3.WAS TANK FILLED WITH YES ❑ NO <br /> 1.ESTIMATED DATE LAST USED(MOIDAY/YR) 2.ESTIMATED QUANTITY OF ,��L <br /> SUBSTANCE REMAINING IJE GALLONS INERT MATERIAL 7 <br /> RJURY,AND TO THE BEST OF MY KNOWLEDGE,EIS TRUE AND CORRECT <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PE <br /> TANK OWNER'S NAME <br /> (PRMTED 6 SIGNATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW TANK# <br /> COUNN# JURISDICTION# FACILITY# <br /> STATE I.D.# m <br /> PERMIT NUMBER PERMIT APPROVED BYlDATE <br /> PERMIT EXPIRATION DATE <br /> MUST BE COMPLETED FOR <br /> THIS FORM MU SHOULD BE ACCOMPANIED BY AIPLO7 PIKE TOHIS FORM WITH THE LOCAL AGE CY IMPLEMENTING TTHEN FRM A UNLESS A CURRENT FORM A HAS BEEN FILED. wGROUND STORA STANK REGULATIONSNS.THIS FORM <br /> FORM B (6-95) <br />