My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SACRAMENTO
>
820
>
2300 - Underground Storage Tank Program
>
PR0231874
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2024 10:48:46 AM
Creation date
11/6/2018 12:04:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0231874
PE
2381
FACILITY_ID
FA0003812
FACILITY_NAME
LODI IRON WORKS
STREET_NUMBER
820
Direction
S
STREET_NAME
SACRAMENTO
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04533004
CURRENT_STATUS
02
SITE_LOCATION
820 S SACRAMENTO ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SACRAMENTO\820\PR0231874\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
9/26/2017 7:48:07 PM
QuestysRecordID
3648617
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• STATE OF CALIFORNIA • <br /> STATE WATER RESOURCES CONTROL BOARD .,,c�+ <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B ,"� LL m <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. " <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ONSITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ <br /> 8 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: U <br /> gZ0 gT. Gpd <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A OWNER'S TANK 1.D.# o I B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAV/YEAR) v, )of:,, D. TANK CAPACITY IN GALLONS: <br /> If.TANK CONTENTS IFA-1 IS MARKED,COMPLETE ITEM C. <br /> A 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C 1a REGULAR UNLEADED ❑ 3 DIESEL ❑ 6 AVIATIONGAS <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY I�Q 1 PRODUCT 1b PREMIUM UNLEADED ❑ 4 GASAHOL ❑ 7 METHANOL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 1C MIDGRADE UNLEADED ❑ 5 JET FUEL ❑ 8 M85 <br /> ❑ 2 LEADED ❑ 99 OTHER(DESCRIBE IN TEM 0.BELOW) <br /> D. IF(A-1)IS NOT MARKED, ENTER NAME OFSUBSTANCE STORED <br /> C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM <br /> ❑ 95 UNKNOWN <br /> SYSTEM g�❑qq 2 SINGLE WALL FL-j-4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> u <br /> B. TANK \, BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ B 10096 METHANOL COMPATIBLE W/FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING ❑ 8 UNLINED /{.� 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? "YEAS_ NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP2 COATING <br /> CORROSION ❑ ❑ 3 VINYL WRAP ❑ d FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE n%5 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL,BIC. SPILL CONTAINMENT INSTIALLED 11'EAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES_ NO_ STRIKER PLATE VES_ NO_ DISPENSER CONTAINMENT YES_ NO_ <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A<r,) SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION <05h SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 1001/6 METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A(V5 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION 1 WO m UNE IFAK ❑2 UNE TKIMNE55 O 3 COMINUWS INTERSTIIAL d ELECIROmC LINE O 5 AUTOMATIC PUMP <br /> MOR TESTING MOMTORRlG LEAK OEIECTOR SHUTDOWN El 99 OTKR <br /> V.TANK LEAK DETECTION <br /> I VISUAL CHECK❑ 7 CONTINUOUS INTERSTITIAL 2 MANUAL RECONCILIATION MONITORING <br /> ❑ 3 MONIITORING OZE ❑ 4 AUTOMATGAUGING MONITORING <br /> TANK ❑ 5 GROUND MONTORING�R a TNNES UALTANK <br /> NG <br /> MONITORING ❑ B SIR ❑ 9 WEEK LY MANUAL ❑ 10 MOTESTINGHLY TANK ❑ 95 UNKNOWN 99 NG <br /> OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE N.PLACE) <br /> 1.ESTIMATED DATER)( /DAV/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> 47 SUBSTANCE REMAINING V GALLONS INERT MATERIAL? YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> TANK OWNER'S NAME <br /> (PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# r5 TANK# <br /> STATE LDS COUNTY <br /> � <br /> PERMIT NUMBER PERMIT APPROVED BV/DATEHERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY PERMIT APPLICATION FORM A,UNLESS A CURRENT FORMA HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS.THIS FORM <br /> FORM B (6-95)SHOULD BE ACCOMPANIED BY A PLOT PLIfLE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE&GROUND STORAGE TANK REGULATIONS <br />