ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0501137
PE
2381
FACILITY_ID
FA0005000
FACILITY_NAME
COMMUNITY FABRICARE INC
STREET_NUMBER
711
Direction
S
STREET_NAME
SAN JOAQUIN
STREET_TYPE
ST
City
STOCKTON
Zip
95203
CURRENT_STATUS
02
SITE_LOCATION
711 S SAN JOAQUIN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SAN JOAQUIN\711\PR0501137\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
9/15/2017 6:54:42 PM
QuestysRecordID
3639381
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• �zo.0 <br /> e <br /> SfpTE OF CAUFORMA <br /> 9 <br /> STATE WATER RESOURCES CONTROL BOARD a' ° <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION• FORM B ^�� va <br /> R� <br /> COMPLETE A SEPARATE FORM FOR EAC NK SYSTEM. °�.�.o.�,.. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ONSITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 6 TANK REMOVED is <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: S 5e?n - Vli 7 4r e� <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.D.# B. MANUFACTURED BY: 4,��i <br /> C. DATE INSTALLED(MO/DAY/VEAR) 63 0. TANK CAPACITY IN GALLONS: O2 0 O O <br /> ILTANKCONTENTS IF A4 IS MARKED,COM EITEM C. <br /> A ICLE FUEL 4 OIL B. G ❑ 1a REGUL R 3 DIESEL ❑ 6 AVIATION GAS <br /> 4 GASAHOL <br /> 2 PETROLEUM ❑ 90 EMPTY 1 PRODUCT ❑ 1DPREMIUM r-1UNLEADED ❑ 5 JET FUEL ❑ 7 METHANOL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOTMARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B.AND C,AND ALL THAT APPLIES IN BOX <br /> A. TYPE OF ❑ UBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER E-] 95 UNKNOWN <br /> SYSTEM GLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTEDTANK) ❑ 99 OTHER <br /> E?r1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B. TANK <br /> MATERIAL ❑ 5 CONCRETE ❑ e POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ B 100% METHANOL COMPATIBLE W/FRP <br /> (PrlmuyT6nk) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> F—] 1 RUBBER LINED E::] 2 ALKYD LINING ❑ 3 EP LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR ❑ 5 GLASS LINING [:] 6 UNLINED 5 UNKNOWN ❑ 99 OTHER <br /> LINING <br /> IS LINING MATERIAL COMPATIBLE WITH 1009: METHANOL? VES_ NO— <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 L WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION F-15 CATHODIC PROTECTION ❑ 91 NONE 5 UNKNOWN ❑ 99 OTHER <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION 10, A U 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A U IQINGLE L A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U TEE A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> A U 7 STEEL W/COATING A U 9 100% METHANOL COMPATIBLE W/FRP <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ 0 MONRTITIAGL OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK 2 INVENTORY RECONCILIATION ❑ 3 VAPOR MONITORING❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> ❑ 6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/VR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES NO <br /> SUOSTANCE REMAINING GALLONS INERT MATERIAL? ❑ [:j <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MV KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANT'S NAME DATE <br /> (PRINTED&SIGNATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TANK# '#601n 1)-7 <br /> STATE I.DA 3 <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br /> FORM B (9.90) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FOR0034&R4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.