My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SARGENT
>
4404
>
2300 - Underground Storage Tank Program
>
PR0541311
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2021 10:10:29 PM
Creation date
11/6/2018 12:33:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0541311
PE
2361
FACILITY_ID
FA0023668
FACILITY_NAME
FRANCES MOORE
STREET_NUMBER
4404
Direction
W
STREET_NAME
SARGENT
STREET_TYPE
RD
City
LODI
Zip
95242
APN
02514043
CURRENT_STATUS
02
SITE_LOCATION
4404 W SARGENT RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SARGENT\4404\PR0541311\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
10/5/2016 5:59:33 PM
QuestysRecordID
3227261
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATEOFCAUFORMA y) <br /> STATE WATER RESOURCES CONTROL BOARD s '� <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 2 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT Q A AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ B TANK REMOVED O <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: �/ p`z- GV . `�- /cw—, '� i�/_�, L G✓J <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS–SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.0.9 /c. , a. MANUFACTURED BY: <br /> v C. DATE INSTALLED(MO/DAYNEAR) ✓-`G 1 D. TANK CAPACITY IN GALLONS: C, SD <br /> ILTANKCONTENTS IFA-I IS MARKED.COMPLETE ITEM C. <br /> A. [�&t MOTOR VEHICLE FUEL ❑ s OILB. C. ❑ 1. <br /> AUNLEADEO REGULAR 8 0 DIESEL ❑ g AVIATION GAS <br /> Q 2 PETROLEUM Q w EMPTY �1 PRODUCT Q lb PREMIUM 6 GASAHOL '❑ ]METHANOL <br /> UNLEADED 5 JET FUEL <br /> Q S CHEMICAL PRODUCT Q % UNKNOWN Q 2 WASTE �2 LEADED El 99 OTHER (DESCRIBE IN ITEM 0. BELOW) <br /> 0. IF(A-I)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.•: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.S.AND C,AND ALL THAT APPLIES IN BOX O AND <br /> A. TYPE OF ❑ I DOUBLE WALL Q 0 SINGLE WALL WITH EXTERIOR UNER UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ A SECONDARY CONTAINMENT (VAULTED TANK) �%99 OTHER <br /> ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ S FIBERGLASS ❑ s STEEL CLAD WI FIBERGLASS REINFORCED PLASTIC <br /> S. TANK METHANOL COMPATIBLE WIF <br /> 6 POLYVINYL CHLORIDE T ALUMINUM B 100X. RP <br /> MATERIAL ❑ s CONCRETE ❑ ❑ ❑ <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL % UNKNOWN ❑ % OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING Q 0 EPDXY LINING ❑ A PHENOLIC LINING <br /> C.INTERIOR ❑ 5 GLASS LINING Q 6 UNLINED �% UNKNOWN ❑' 90 OTHER <br /> LINING <br /> IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? YES_ NO— <br /> D.CORROSION ❑ I POLYETHYLENE WRAP ❑ 2 COATING F7 7 VINYL WRAP ❑ A FIBERGLASS REINFCRCED PLASTIC <br /> PROTECTION Q 5 CATHODIC PROTECTION ❑ 91 NONE UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAWMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IFUNOERGROUNO.BOTHIFAPPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U S GRAVITY A U W OTHER <br /> S. CONSTRUCTION A U 1 SINGLE WALL A U 2 DOUBLE WALL A U S LINED TRENCH A(3�715 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U I BARE STEEL A U 2 STAINLESS STEEL A U 0 POLYVINYL CHLORIOE(PVC)A U A FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U T STpihEE-L-�W�ICOATING A U 6 100% METHANOL COMPATIBLE WIFRP <br /> KNI <br /> PROTECTION A U 9 GALVANIZED STEEL U 10 CATHOOICPPOTECTA 4L UNKNOWN A U 99 OTHER <br /> 0. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ T MONRORIIA 99 OTHER L a� <br /> V.TANK LEAK DETECTION <br /> 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 7 VADOZF MONITORING ❑ A AUTOMATIC TANK GAUGING Q 5 GROUND WATER MONITORING <br /> 6 TANK TESTING Q 7 INTERSTMALMONITORING ❑ 91 NONE % UNKNOWN Q % OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1,ESTIMATED OATSq U 0 <br /> T 17AYIYR) 2 ESTIMATED OUANTRY OF 1 WAS TANK FILLED WITH YES ❑ NO❑ <br /> �4 SUBSTANCE PENIAINING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE IS TRUE AND CORRECT <br /> APPLICANTS NAME DATE <br /> PRINTE0651GNATJRCI <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY�9 JURISDICTION 9 FACILITY 9 TANK 9 r.� <br /> STATE I.D. W II =1 I I I� <br /> PERMIT NUMBER PERMIT APPROVED BYIDATE I PERMIT EXPIRATION DATE <br /> FORM 8 (7-91) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPUCATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FOR0mA6diS <br />