Laserfiche WebLink
UST Program: Monitoring Plaj$r UST Tank ...: CERS Regulator Page 1 of 2 <br /> California Environmental Reporting System:Regulator vicki mccartnev's Account Sian Out Tools Reports Heb <br /> Submittals Facilities Businesses Regulators Compliance Responders Reports <br /> UST Monitoring Plan: Fast Lane Central Valley <br /> Home 2) Submittal Search D Submittal:711812016 00063345 )) UST:UST Monitoring Plan(Accepted) <br /> Submittal Element History <br /> Submitted for CERS ID 10063345 on 7/18/2016 2:59PM by Hardeeo Gi11 of Fast Lane Central Valley(Lathrop,CA) <br /> Submittal was Accepted on 7/21/2016 by NG, IMLLYfor San Joaquin County Environmental Health <br /> 12. View Tank Information Return to Submittal <br /> Ita <br /> Gopy Monitoring Plan Informatihis section would allow the user to copy Monitoring Plan information from another tank.This option would only appear if this facility had one or more existing <br /> nks with Monitoring Plans. <br /> Facility Information 1 quipment Testing and Preventive Maintenance Monitoring Location <br /> Fast Lane Central Valley Monitoring Equipment Serviced Site Plot Plan Submitted <br /> 116 Roth Rd Annually Site Plan Previously Submitted <br /> Lathrop, CA 95330 - - <br /> Tank Monitoring is Performed Using the Following Methods <br /> Yes Continuous Electronic Tank Monitoring it <br /> Secondary Containment System Monitor Panel Manufacturer Leak Sensor Manufacturer <br /> Under Vacuum Veeder Root Veeder Root <br /> Monitor Panel Model Leak Sensor Model# <br /> TLS-350 Plus 303 <br /> No Automatic Tank Gauging 6 <br /> No Monthly Statistical Inventory Reconciliation L <br /> No Weekly Manual Tank Gauge u No Tank Integrity Testing y <br /> No Other Monitoring ti <br /> Pipe Monitoring is Performed Using the Following Methods <br /> Yes Continuous Monitoring of Piping Secondary Containment u <br /> Piping Secondary Containment Panel Manufacturer Leak Sensor Manufacturer <br /> Pressurized Veeder Real Veeder Root <br /> Panel Model# Leak Sensor Model <br /> TLS-350 Plus 208 <br /> Leak Alarm Triggers Automatic Pump Shutdown -. Yi—:) s a" ri fy j <br /> FailurelDisconnect Triggers Pump Shutdown -:',— ! J�y�f`'' <br /> �s V 4e Jos <br /> Yes Mechanical Line Leak Detector Performs 3 GPH Leak Test to <br /> MLLD Manufacturer MLLD Model <br /> VMI 99LD20O0 <br /> No Electronic Line Leak Detector Performs 3 GPH Leak Test a <br /> No Pipeline Integrity Testing a No Visual Pipeline Monitoring 44 <br /> No Suction Piping Meets Exemption Criteria's <br /> No No Regulated Piping Per Health and Safety Code,Division 20,Chapter 6.7 Is Connected To The Tank System`tr <br /> NoOther Pipeline Monitoring w <br /> Under Dispenser Containment(UDC)Monitoring <br /> UDC Monitoring Detection of Leak into UDC Triggers Audible and Visual Alarms <br /> Continuous Yes <br /> UDC Leak Alarm Triggers Automatic Pump Shutdown <br /> UDC Panel Manufacturer Yes <br /> Veeder Root FailurelDiscornection of UDC Monitoring System Triggers Automatic Pump Shutdown <br /> UDC Panel Model# Yes <br /> TLS 350 PLus UDC Monitoring Stops Flow of Product at Dispenser <br /> UDC Leak Sensor Manufacturer Yes <br /> Veeder Root UDC Construction <br /> UDC Leak Sensor Model Doubl"alled <br /> 208 UDC Secoe n amrnen on orn <br /> Pressure ,� °U'CERS Help 'i1`f Sett+ngs <br /> https://cersregulator.calepa.ca.gov/Business/333541Facility/10063345/Submittal/UST/178,.. 11/17/2016 <br />