Laserfiche WebLink
#&AZGE1VEL) <br /> NOV D 2 2016 <br /> Appendix VI _ <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available i t � DEPARTMENT <br /> v�}TDEPARTMENT <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited. Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> ownerloperator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Fast Lane Central Valley (Truck Side) Bldg.No.: — <br /> Site Address: 116 E Roth Rd city: Lathrop, CA zip: 95330 <br /> Facility Contact Person: Hardeep Gill Contact Phone No.: 707-326-0369 <br /> Make/Model of Monitoring System: VR — 3 50 Date of Testing/Servicing: 6/17/2016 <br /> B. inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment ins ected/serviced: <br /> Tank ID: 1 — Diesel South Tank ID: <br /> 0 In-Tank Gauging Probe. Model: MAG-7 _ In-Tank Gauging Probe. Model: <br /> 0 Annular Space or Vault Sensor. Model: 303 Annular Space or Vault Sensor. Model. <br /> 0 Piping Sump I Trench Sensor(s). Model: 208 - Piping Sump/Trench Sensor(s). Model: <br /> 0 Fill Sump Sensor(s). Model 208 Fill Sump Sensor(s). Model: <br /> 10 Mechanical Line Leak Detector. Model: 99LD2000 i Mechanical Line Leak Detector. Model: <br /> -i Electronic Line Leak Detector, Model: I Electronic Line Leak Detector. Model: <br /> Tank Overfill 1 High-Level Sensor. Model: I Tank Overfill l High-Level Sensor. Model: <br /> Other(specify equipment t e and model in Section E on Page 2). I Other(specify equipment t e and model in Section E on Page 2). <br /> Tank ID: 2 — Diesel North Tank ID: <br /> 0 In-Tank Gauging Probe. Model: MAG-7 In-Tank Gauging Probe. Model: <br /> 0 Annular Space or Vault Sensor. Model: 303 Annular Space or Vault Sensor. Model: <br /> • Piping Sump/Trench Sensor(s). Model: 208 J Piping Sump I Trench Sersor(s). Model: <br /> Q Fill Sump Sensor(s). Model: 208 7 Fill Sump Sensor(s). Model: <br /> Q Mechanical Line Leak Detector. Model: 99LD2000 I Mechanical Line Leak Detector. Model: <br /> L Electronic Line Leak Detector. Model: 1 I Electronic Line Leak Detector. Model: <br /> Tank Overfill I High-Level Sensor. Model: C Tank Overfill 1 High-Level Sensor. Model: <br /> Other(specify equipment t e and model in Section E an Pacie 2). - Other(specify equipment t e and model in Section E on Page 2). <br /> Dispenser ID: 13 Dispenser ID: 16 _ <br /> 0 Dispenser Containment Sensor(s). Model: 208 0 Dispenser Containment Sensor(s). Model: 208 <br /> L✓7 Shear Valve(s). © Shear Valve(s). <br /> Dispenser Containment Floats and Chains. _ Dispenser Containment Float s and Chains. <br /> Dispenser ID: 14 Dispenser ID: 17 <br /> 0 Dispenser Containment Sensor(s). Model: 208 0 Dispenser Containment Sensor(s). Model: 208 <br /> 0 Shear Valve(s). 0 Shear Valve(s). <br /> Dispenser Containment Floats and Chain(s). 11 Dis enser Containment Floats and Chains. <br /> Dispenser ID: 15 Dispenser ID: 18 <br /> 0 Dispenser Containment Sensor(s). Model: 208 0 Dispenser Containment Sensor(s). Model: 208 <br /> 0 Shear Valve(s). 0 Shear Valve(s). <br /> Dispenser Containment Floats and Chain(s). Dis enser Containment Floats and Chains. <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information(e.g. manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br /> copy of the report;(check all that apply): - System set-up Alarm history report °lJ�/ <br /> Technician Name(print): Alvin L. Milburn Signature: /`r <br /> Certification No.: A27843 License. No.: 956593 <br /> Testing Company Name: EPIC Environmental Compliance Systems Inc. Phone No.: 888-700-EPIC <br /> Testing Company Address: 39120 Argonaut Way ## 643, Fremont, CA 94538 DatecfTestinglServicing: 6/17/2016 <br /> Monitoring System Certification Page 1 of 5 12/07 <br /> 1 2121107 <br />