Laserfiche WebLink
• <br /> ORECEIVED <br /> NOV 0 2 2016 <br /> Appendix VI �I J <br /> (Copies of Monitoring System Certification firm and UST Monitoring Plot Plan available aKNMEUTALMEALTH <br /> MONITORING SYSTEM CERTIFICATION DEPARTMENT <br /> For Use By All Jurisdictions Within the State of Califomia <br /> Authority Cited. Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be,prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> ownerloperator. The ownerloperator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Fast Lane Central Valley (Auto Side) Bldg.No.: — <br /> Site Address: 116 E Roth Rd city: Lathrop, CA zip: 95330 g <br /> Facility Contact Person: Hardeep Gill Contact Phone No.: 707-326-0369 <br /> �1 <br /> Make/Model of Monitoring System: VR – 350 Date of Testing/Servicing: 6/16/2016 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment ins ectediserviced: <br /> Tank ID: 1 – 87 Tank ID: 3 – Diesel <br /> IZ In-Tank Gauging Probe. Model: MAG-7 D In-Tank Gauging Probe. Model: MAG-7 <br /> Z Annular Space or Vault Sensor. Model: 303 R Annular Space or Vault Sensor. Model: 303 <br /> ® Piping Sump l Trench Sensor(s). Model: 208 I0 Piping Sump 1 Trench Sensor(s). Model: 208 <br /> Q 1`1I Sump Sensor(s). Model: 208 Q Fill Sump Sensor(s). Model: 208 <br /> ® Mechanical Line Leak Detector. Model: 99LD2000 0 Mechanical Line Leak Detector. Model: 99LD2000 <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill 1 High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment t e and model in Section E on Pa a 2). Others eci equipment t e and model in Section E on Page 2). <br /> Tank ID: 2 - 91 Tank ID: <br /> © In-Tank Gauging Probe. Model: MAG-7 In-Tank Gauging Probe. Model: <br /> 0 Annular Space or Vault Sensor. Model: 303 Annular Space or Vault Sensor. Model: <br /> Evl Piping Sump 1 Trench Sensor(s). Model: 208 Piping Sump l Trench Sensor(s). Model: <br /> • Fill Sump Sensor(s). Model 208 Fill Sump Sensor(s). Model: <br /> • Mechanical Line Leak Detector. Model: 99LD2000 Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: -, Tank Overfill/High-Level Sensor. Model: <br /> Other(specify a ui rnent type and model in Section E an Page 2). Other(specify equipment t e and model in Section E on Pae 2). <br /> Dispenser ID:, 1 12 Dispenser ID: 7 Z 8 _— <br /> Q Dispenser Contalnment Sensor(s). Model: 208 0 Dispenser Containment Sensor(s). Model: 208 <br /> © Shear Valve(s). ® Shear Valve(s). <br /> - Dispenser Containment Fioai s and Chain(s). I Dispenser Containment Floats and Chain(s). <br /> Dispenser ID:, 3 / 4 Dispenser ID:_9 / 10 <br /> * Dispenser Containment Sensor(s). Model: 208 Q Dispenser Containment Sensor(s). Model: 208 <br /> * Shear Valve(s). Z Shear Valve(s). <br /> Dispenser Containment Floats and Chains. 1 Dispenser Containment Floats and Chains. <br /> Dispenser ID; 5 / 6 Dispenser ID. 11 / 12 <br /> RI Dispenser Containment Sensor(s). Model: 208 0 Dispenser Containment Sensor(s), Model 208 <br /> ® Shear Valve(s). L Shear Valve(s). <br /> Dispenser Containment Floats and Chair(s). rl Dispenser Containment Floats and Chains. <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information(e.g. manufacturers' checklists) necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): _ System set-up Alarm history report <br /> �� 7 <br /> Technician Name(print): Alvin Milburn Signature: t��"'rrjl�""- <br /> Certification No.: A27843 License.No.: 956593 <br /> Testing Company Name: EPIC Environmental Compliance Systems Inc. Phone No.: 888-700-EPIC <br /> Testing Company Address: 39120 Argonaut Way # 643, Fremont, CA 94538 Date of TestinglServicing: 6/16/2016 <br /> Monitoring System Certification Page 1 of 5 12107 <br /> 1 2/21/07 <br />