My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016 - 2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
116
>
2300 - Underground Storage Tank Program
>
PR0523684
>
COMPLIANCE INFO 2016 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2023 2:34:16 PM
Creation date
11/6/2018 12:48:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2017
RECORD_ID
PR0523684
PE
2351
FACILITY_ID
FA0015977
FACILITY_NAME
Fast Lane Central Valley
STREET_NUMBER
116
STREET_NAME
ROTH
STREET_TYPE
Rd
City
Lathrop
Zip
95330
APN
196-02-020
CURRENT_STATUS
01
SITE_LOCATION
116 Roth Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\R\ROTH\116\PR0523684\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
4/24/2018 11:35:23 PM
QuestysRecordID
3866361
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
270
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> relephane$(209)Ogg 3420 Fax: 'lton Avenue Stockton, California 95205-6232 <br /> (209)468-3433 Web:www.s� ov.or /ehd <br /> Underground Storage Wank Program Ins <br /> Facility Name: <br /> rt <br /> Fast Lane Central Valley I�eCtlOn I�E'I]p <br /> Facility Address: Facility Phone: <br /> 116 Roth Rd, Lathrop CA 95330 (707) 431-3510 Date: <br /> Inspection Contact: August 08, 2016 <br /> Agnes MabalotTitle: CERs ID:Inspection Type: Manager Phone: 10063345 <br /> INSPECTION/REINSPECTION 1 hr minimum (209) 234 4341 <br /> Consent For: Program: <br /> 2351 - UST FACILITY-2481 COMPLIANT <br /> CI Ins et;tion 9 Photos ® Consent riven ay; <br /> Service Technician Onsite: Sam les Agnes Mabalot, Manager <br /> Alvin Milburn Exp.Date: Designated Operator: <br /> Service Technician Manufacturer's Training 11/05/2016 Brian Dunahay <br /> Veeder Root, 07/12/17; VMI, 03/13118 Exp•Date: <br /> 12!09/2016 <br /> CCR=California Code of Regulations HSC=Health and Safety Code CFR= <br /> Code of Federal Regulations <br /> V=Violation R=Repeal violating inspectio on Cpg= <br /> Fife Reviews Corrected on site duri <br /> T 01 HSC 25284 No permit to operate <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system ❑V ❑R <br /> ❑COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted o V °R COS <br /> 104 CCR 2711 UST operating Permit a ❑pplication for facility and tank information not submitted or current •V ■R COS <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan NV ■R ❑COS <br /> 106 CCR 2632(d)(2) Failed to have an approved LIST response plan ■V ■R a COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed ❑V DR a COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing EV •R ❑COS <br /> 109 CCR 2637 Failed to test secondary containment °V ❑R ❑COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days °V c R ❑'COS <br /> 111 CCR 2638(x) Failed to test monitoring and leak detection equipment annually ❑V ❑R o COS <br /> 112 HSC 25284.2 Failed to test spill containers annually EV ❑R ❑COS <br /> 113 CCR 2638(4) Failed to submit monitoring system certification test report within 30 days °V °R ❑COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down ❑V D R o COS <br /> 115 CCR 2715(a) p p g ❑�` a R ❑C05 <br /> ( ) Failed to inform the EHD of designated operator identification or change within 30 days <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification ❑V ri R u COS <br /> 117 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after 1 V °R °COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests l V °R V DR i COS <br /> COS <br /> 119 HSC 25299 Documents were falsified or misrepresented � <br /> 120 CCR 2635(d) Failed to submit UST Certification of InstallationlModification L,V ❑R o COS <br /> 121 CCR 2712(fl Failed to submit a written response within 30 days of receiving an inspection report n V ri R ❑COS <br /> 122 CCR 2631{j) Failure to submit UST system component statement of compatibility for substance storedV °R ❑COS <br /> ❑V ❑R ❑COS <br /> On Site Records <br />>01 CCR 2712(b) Failed to maintain alarm togs and/or records of follow up actions <br />!02 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 1/2 years RV c R ❑COS <br />!03 CCR 2712(b) �,V ❑R ❑COs <br /> Failed to maintain records of monitoring, repair,lining,and upgrades on site <br /> ■V ❑R uCOS <br /> Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.