San Joaquin county <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax: (209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Fast Lane Central Valley 1 116 Roth Rd, Lathrop June 16 2016 <br /> UST System Observations <br /> 326 CCR 2631.1 UST system not compatible with the substance stored u V u R u COS <br /> 327 HSC 25298(b) Failed to comply with temporary closure requirements u V u R u COS <br /> 328 HSC 25298(c) Failed to comply with permanent closure requirements u V u R u COS <br /> 329 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system ❑V a R D COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ,V n R n COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed L-:V u R u COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) u V u R _i COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) u V u R u COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation n V u R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation a V o R o COS <br /> 2060 See below Unlisted Design/Construction violation ❑V rs R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted. <br /> Financial responsibility documents submitted to CERS and the San Joaquin County Environmental Health Department <br /> (FHD) are not correct. Remove 500,000 dollars per occurrence and add either 1 million dollars annual aggregate or 2 <br /> million dollars annual aggregate. Note: the current Certification of Financial Responsibility terminates on 6/30/2016. <br /> Current financial responsibility documents are required to be submitted annually. Immediately log into the California <br /> Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/, and upload the required documents <br /> This is a minor violation. <br /> 104 CCR 2711 UST Operating permit Application for Facility and Tank information not submitted or current. <br /> UST Facility Operating Permit is not current in CERS. The Board of Equalization number is not valid. Any change of <br /> information must be updated in CERS within 30 days of the changes. Immediately log into CERS, update the required <br /> information, and submit for review by the EHD. <br /> UST Tank Information forms for the underground storage tanks (UST) T1, T2, T3, T4, and T5 are not current in CERS. <br /> There is no Corrosion Protection identified in CERS.; T3 -beneath Vent, Vapor Recovery (VR) and Riser/Fill Pipe <br /> Piping Construction, remove"Fiberglass" from the Vapor Recovery Primary and Secondary Containment since there is <br /> no vapor recovery for the diesel product. For T1 and T2, beneath Vent, Vapor Recovery (VR) and Riser/Fill Pipe Piping <br /> Construction, change Riser Pipe Primary Containment from Fiberglass to Steel. Any change of information must be <br /> updated in CERS within 30 days of the changes. Immediately log into CERS, update the required information, and <br /> submit for review by the EHD. <br /> This is a repeat violation, Class II. <br /> Page 3 of 4 <br />