Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Wert':www.sjgov.orgfehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Fast Lane Central Valley 1 116 Roth Rd, Lathrop June 20, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II, or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. <br /> For all five underground storage tanks: under Pipe Monitoring is Performed Using the Following Methods, add the <br /> brine interstitial 304 sensor to"Leak Sensor Model", and add "Yes" to Leak Alarm Triggers Automatic Pump <br /> Shutdown, and "Yes' to Failure Disconnect Triggers Pump Shutdown; beneath Under Dispenser Containment <br /> (UDC) Monitoring, add the brine interstitial 304 sensor; under Recordkeeping, change "No" to"Yes" for Equipment <br /> Maintenance and Calibration Records. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a repeat violation, Class II. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. A site plan is a facility map that must be submitted <br /> identifying the locations where monitoring will be performed. Immediately log into the California Environmental <br /> Reporting System (CERS) at http://cers.calepa.ca.gov/, remove the Underground Storage Tank Monitoring Plan <br /> currently in CERS, and upload a copy of the UST Monitoring Site Plan (map). <br /> This is a repeat violation, Class II. <br /> 120 CCR 2635(4) Failed to submit UST Certification of[nstallation/Modification. <br /> B-20 Biodiesel(between 5 and 20 percent)was recently added to the diesel underground storage tanks and the <br /> UST Certification of Installation/Modification has not been submitted. This certification is required to be submitted <br /> within 30 days of completion of work to the California Environmental Reporting System (CERS). Immediately log <br /> into CERS, complete the required information, and submit for review by the EHD. <br /> This is a minor violation. <br /> FA0015977 PRO523684 SC001 06/20/2017 <br /> END 23-01 Rev.09/22/16 Page 5 of 11 Underground Storage Tank Program OIR <br />