My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1986 - 1992
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
707
>
2300 - Underground Storage Tank Program
>
PR0502003
>
BILLING 1986 - 1992
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2024 4:28:40 PM
Creation date
11/6/2018 12:57:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1986 - 1992
RECORD_ID
PR0502003
PE
2381
FACILITY_ID
FA0005297
FACILITY_NAME
SYSTEM TRANSPORT INC
STREET_NUMBER
707
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19332008
CURRENT_STATUS
02
SITE_LOCATION
707 E ROTH RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\R\ROTH\707\PR0502003\BILLING 1986 - 1992.PDF
QuestysFileName
BILLING 1986 - 1992
QuestysRecordDate
6/28/2018 9:19:42 PM
QuestysRecordID
3929853
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORN16 WATER RESOURCES CONTROOARD <br /> FORM 'B': UNDERGROUND STORAGE TANK PROGRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWINO INFORMATION FOR EACH TANK. <br /> MARK ONLY ❑ I NEW PERMIT ❑3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑7 PERMANENTLY CLOSED TANK <br /> 10 <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑6 TANK REMOVED 6- <br /> p FARMTANK-YES❑ NO ❑ N <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: V <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY W <br /> A. OWNERS TA <br /> IDN <br /> O-31 B. MANUFACTURED BY: <br /> C. YEAR INSTA LED D. TANK CAPACITY IN GALLONS: Q� <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. 1 MOT RVEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑ 2 LEADED 3 DIESEL <br /> ❑3 CHEN ICAL PRODUCT ❑ 4 OIL PRODUCT ❑4 GASAHOL ❑5 JET FUEL ❑6 AVIATION GAS <br /> ❑ 5 HAD RDOUS E] 80 EMPTY E]95 UNKNOWN ❑ 2 WASTE ❑T METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MIDI OR VEHICLE FUEL,ENTER NAME OF C.A.S.#: <br /> HAZARDOU SUBSTANCE STORED&C.A.S.# <br /> III. TANK CO 4STRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A. TYPE OF ❑ 1 DOUBLEWALLED ❑ 3 SINGLE WALLED WITH EXIERIORLINER 95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> 15TEELIIRON ❑25TAINLE55 STEEL ❑ 3RBERGLASS ❑4STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑7 ALUMINUM ❑6100%METHANOL COMPATIBLE FRP <br /> MATERIAL ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER UNED ❑ 2 ALKYD LINING ❑ 3 EPDXY LININGn('PHENOLIC LINING <br /> C <br /> LINING INTERIOR F-15 GLASS UNING F-16 UNLINED 95 UNKNOWN <br /> ❑IS LINING MATERIAL COMPATIBLE WIT 10096METHANOL9 ❑YES ❑ NO ❑99 OTHER <br /> D. CORROSION F] 1 POLYETHLENE WRAP 2TAR OR ASPHALT ❑3VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑91 NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMAT N CIRCLE A IFABOVEGROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE U SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUOTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE 5 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYLCHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEELCLADW/FRP A U B 10D%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A 9 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> / P S 1 VISUA-CHECK 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUNDWATER MONITORING WELLS <br /> /} P S 6 PRECISION TESTING P S 7 PRESSURETESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> �i- VI. INFORM TION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 2. 3.WAS TANK FILLED WITH <br /> ESTIMATED QUANTITY OF <br /> 1. ESTIMAT DATE LAST USED(MO/YR) SUBSTANCE REMAINING IN <br /> GALLONS INERT MATERIAL? ❑YES ❑ NO <br /> THIS F RM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> DATE <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> l <br /> FCHECK* <br /> LOCAL AGENCY FACILITY ID# <br /> APPROVED BV NAME PHONE#WITH AREA CODE <br /> 21211,70 <br /> gAt7oUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> BY:p <br /> PERMIT AMOUNT SURCHARGE AMT. FEE CODE ECEIPT# f LL <br /> FORM B(6-29-9B) THIS FORM MUST BE ACCOMPANIED BY A FACILITYISITE <br /> DATA PPR TION, NOGRMOA',UNLESS A CURRENT FORMA' HAS BEEN FILED <br />
The URL can be used to link to this page
Your browser does not support the video tag.