R
>
ROTH
>
707
>
2300 - Underground Storage Tank Program
>
PR0505735
>
BILLING 2008 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2023 3:16:23 PM
Creation date
11/6/2018 1:03:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2008 - 2015
RECORD_ID
PR0505735
PE
2361
FACILITY_ID
FA0006972
FACILITY_NAME
TSI TRANS SYSTEM INC
STREET_NUMBER
707
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231-9774
APN
19332008
CURRENT_STATUS
01
SITE_LOCATION
707 E ROTH RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\R\ROTH\707\PR0505735\BILLING 2008 - 2015.PDF
QuestysFileName
BILLING 2008 - 2015
QuestysRecordDate
6/28/2018 11:46:54 PM
QuestysRecordID
3930653
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'IED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORING]PLAN (Page 2 or 2) <br /> VI.UNDER DISPENSER CONTAINMENT(UDC) MONITORING <br /> . UDC MON[ ORING IS PERFORMED USING THE FOLLOWING METHOD <br /> 1,CONTINUOUS ELECTRONIC MONITORING ❑ 2.FLOAT AND CHAIN ASSEMBLY .unuae <br /> ❑ 3.ELECTRONIC STAND-ALONE <br /> ❑J.NO DISPENSERS ❑99,OTHER(Specify): <br /> __ PANEI_MA WrAMURER:Vecdarmal 4MF55 MODEL#:TL53011C <br /> LEAK EN RMANUFACTURER:Vicedcraal }91F57 MODEL#(S):79d3RU•2Ug ..� +'�11-cn l <br /> DET@CI'Ip OFA LEAK INTO THE UOC TR IGGERS AUDIBLC•AND VISUAL ALARMS ® a.YES ❑b.NO •1°°"' <br /> UDC LEA ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN ® a.YES ❑b,NO <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP Si IUTDOWN. R ',YES ❑b.NO <br /> _UDC MON PORING STOPSTHE FLOW OFPRODUCTATTHE DISPENSER. ® n.YES <br /> ❑b.NO 491u,2 <br /> 2.UDC CONS UCTION IS ®I.SINGLE-WALLEI) ❑2,DOUBLE-WALLED S�UiFTII <br /> IF DOUDL.WALLED: - -- <br /> 9u.w,l <br /> UDC[NTE STITIAL SPACG IS MON 11.011ED BY: O I.LIQUID 2. <br /> ❑ PRESSURE [13.VACUUM <br /> A LEAK WITHINTHE SECONDARY CONTAINMENTOFTHE UDCTRIGGERS AUDIBLE AND VISUAL ALARMS ❑u.YGS ❑h. NO <br /> VQ.PERIODIC SYSTEM TESTING <br /> I. ELD TT ING:THIS PACIUTY HAS BEEN NOTIFIED BY TIIE STATE WATER RESOURCES CONTROL 60AIZ11 'I'I IAT ENHANC"D 4'111.45 <br /> AK D E ION CELD MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTIIS AS REQUIRED_( CCR�26JJ _ _ <br /> ®-SECOND RY CON'TAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS, a9o-1H, <br /> [.SPILL BU KETSARETESTED pNNUAi.LY. — <br /> +9a+,- i <br /> VIII.RE,CORDKEEPING — <br /> Thu following am litOdlig/Inzinlanance records:re kept for this facility: <br /> ®Alarm logs r1wm, ❑Visual Inspection Records 490.681, ❑Tank integrity testing r051111is.I91144 <br /> ❑SIR testing re IIs(and supporting documentation records). 491I.Ml ® yank gauging results(and supposing documemmiion records). neo-rate <br /> N ATO Testing rmulis(and supporting documentation records).amuxr ❑ Corrosion Protection 60-day logs mnraeg <br /> Equipment ran <br /> 'q p monnnce and calibration records. a9oann <br /> h ui <br /> 11 1 <br /> IX.TRAINING <br /> ®Pursonnel Willi UST monitoring responsibilities are familiar with all of the following documents relevant to their)ob di 47tl.rna <br /> iEFERENCE E OCUMENTS MAINTAINED AT FACILITY(Check all oral apply) <br /> ® TRIS UNI ERGROUND STORAGE TANK MONITORING PLAN(Required)490.a9h <br /> ® OPERATI G MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required)amt.ax <br /> ® <br /> CALIFOR 41A UNDERGROUND STORAGE TANK REGULATIONS.9xl.rna <br /> ❑ CAI.IFOR NIA UNDERGROUND STORAGE TANK LAW 490.r9v <br /> ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATIS )CAL INVENTORY RECONCILIATION"amunr <br /> ❑ SWRCB P BLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYS'T'EMS"axw9g <br /> ® OTHER( ecify):htn mra <br /> ®This facility II o`Designated UST Operator"who has passed the California UST System Operator Exnm administered by the International Code Cauncil(ICC). I <br /> The"Designated L ST Operamr'will train filcility employees in the proper operation and maintenance of the UST systems annually,and within 30 Jays of hire This <br /> [mining will inclu ,but is not limited to,the following: <br /> 7 Operation orme Us'r systems in u manner consistent with the facility's best management practices <br /> The facility eemployee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan <br /> r <br /> The facility mplayee's rale With regard to spills and overfills as specified in the USI'Response Plan <br /> D Names of nlact person(s)far emergencies and monitoring alarms.49(1-70 <br /> X. COMMENTS/ADDITIONAL INFORMATION <br /> Provide additional comments here or indicate lima many pages wish:uldilional information on specific monitoring procedures arc attached to this FIRM 1110-71 ' <br /> Spilt Bucket around fill pipe-90%N shun down Mapper valve, <br /> XI.PERSONNEL RESPONSIBILITIES <br /> The UST Owner/Operator is responsible for ensuring that:1)the daily/romine UST monitoring activities and maintenance of UST leak detection equipment covered by_i <br /> Ihisplan occurs,2) II conditions[hit]indicate a possible release ure investigated,and 3)all monitoring records are maintained properly. <br /> The fallowing pers Fula)are responsible for performing the monitoring and equipment maintenance: <br /> NAME Sam Alburtis .Ixr•n TITLE Shop Manager <br /> aI6D <br /> NAME Don McILmIh rmaa 'TITLE Designated Operator UST <br /> 49675 <br /> 'The Designed Operator shall perform a monthly visual inspection of the facility, provide a report to the owner/operator, and inform the owner/opennor of Filly <br /> mndiitons that nee follow-u action. <br /> 16 XII.OWNEWOPERATOR SIGNATURE <br /> ERTIFICATI N: I certify that the information provid herein is true and accurate to the best of m knowledge. <br /> APPLICANTSIG TORE rxwa DATE: re1.n <br /> 5/17/2010 <br /> `x <br /> ..aim <br /> II ] I'a�i 1-1h41x J 91 mritnllte ,-a <br /> APPLICANT NAM (print): 491X11 APPLICANTTITLE: "xFnr <br /> Steven Ray Tuc er Regulatory Compliance Manager <br /> parr ncT_n nor 1171 ird <br />
The URL can be used to link to this page
Your browser does not support the video tag.