My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SCHULTE
>
17880
>
2300 - Underground Storage Tank Program
>
PR0524020
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2021 10:11:05 PM
Creation date
11/6/2018 1:12:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0524020
PE
2332
FACILITY_ID
FA0010273
FACILITY_NAME
Costco Wholesale #210
STREET_NUMBER
17880
Direction
W
STREET_NAME
SCHULTE
STREET_TYPE
Rd
City
Tracy
Zip
95377
CURRENT_STATUS
02
SITE_LOCATION
17880 W Schulte Rd
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SCHULTE\17880\PR0524020\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
12/27/2016 9:32:16 PM
QuestysRecordID
3299612
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM s/61 f 0� <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE I <br /> (two pages per tank) <br /> [II NEW SITE PERMIT Page_of <br /> TYPE OF ACTION <br /> ❑ 4 AMENDED PERMIT ❑ S.CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check weilemonly) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specifyreuon-farlacni aonb) (Specifymuon-forlocalmonly) ❑ 8 TANKREMOVED <br /> BUSINESS NAME(Same as FACMITY NAMEor DBA Doing Baainm As) FACILITYID: 1 <br /> J <br /> LOCATION WITHIN SITE(opoonap 431 <br /> I.TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landirmurks shall be submitted to the local agency.) <br /> T-AN/K ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK Yes ❑ No 434 <br /> T/1,L S� Ya',wmplc a oro pa8e for e h compuonenL <br /> i DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY M GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> ADDITIONAL DESCRIPTION(For local uae only) 438 <br /> II.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 410 <br /> ❑I. MOTOR VEHICLE FUEL ❑ Is. REGULAR UNLEADED 02. LEADED ❑5. JET FUEL <br /> (IfnatkN cantplea Pewlean Type) ❑lb. PREMIUM UNLEADED 03. DIESEL ❑6.AVIATION FUEL <br /> ❑2.NON-FUEL PETROLEUM ❑Ic. MIDGRADE UNLEADED 114. GASOHOL 99.OTHER <br /> ❑3. CHEMICAL PRODUCT COMMON NAME(nom Hod.Matmala lnvemorypage) I CAS#(fiomHmrdou Meteriala lnvsnary page) 4R <br /> ❑4. HAZARDOUS WASTE <br /> (Incloh Uaaa W) <br /> ❑95.UNKNOWN <br /> 111. TANK CONSTRUCTION <br /> TYPEOFTANK 1. SINGLE WALL 03. SINGLE WALL WITH LJ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Chock one item only) EXTERIOR MEMBRANE LINER 095.UNKNOWN - <br /> ❑2. DOUBLE WALL ❑4. SIGNLE WALL IN VAULT ❑99.OTHER <br /> TANK MATERIAL-primuyin* 0 1. BARE STEEL 0 3. FIBERGLASS/PLASTIC U 5.CONCRETE 0 95.UNKNOWN 4M <br /> (Check one asrn only) ❑2.STAINLESS STEEL ❑4. STEEL CLAD WJFIBERGLASS ❑S. FRP COMPTIBLE W/100%METHANOL ❑99.OTHER <br /> REINFORCEDPLASTIC(FRP) <br /> TANK MATERIAL-secondary lank U 1. BARE STEEL U 3. FIBERGLASS/PLASTIC US. CONCRETE U 95.UNKNOWN N5 <br /> (Caeckone iononly) ❑2. STAINLESS STEEL ❑4. STEEL CLAD WJFIBERGLASS ❑S. FRP COMPTIBLE W1100%METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) )TIO.COATED STEEL <br /> ❑S. CONCRETE <br /> TANK INTERIOR LINING 1.RUBBER LINED 0 3.EPDXY LINING 0b.GLASS LINING 0 95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING ❑6 UNLINED ❑99 OTRER <br /> (Checks.n item ooly) (Far lawlus only) <br /> OTHER CORROSION ❑1 MANUFACTURED CATHODIC ❑3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 44g DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION ❑4IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE (For loal vee only) <br /> SPILL AND OVERFILL YEAR INSTALLED 4% TYPE(w lure only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 1 452 <br /> (Oecka110areMly) ❑1 SPILL CONTAINMENT <br /> 0 ALARM. ❑3FILL TUBE SHUT OFF VALVE <br /> ❑2 DROP TUBE ❑2 BALL FLOAT ❑4 EXEMPT <br /> ❑3 STRIKER PLATE <br /> IV.TANK LEAK DETECTION(Adeampuon o(tacmoniaring program"I M submiuNm do,]..I agency.) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Check one ilnnonly) <br /> ❑I VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑i VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) [:16 VADOSE ZONE ❑2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> (SIR) BIENNIAL TANK TESTING ❑990THER <br /> IV.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons ❑Yes ❑ No <br /> UPCF(12/99 revised) 10 Formerly SVTRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.