My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SCHULTE
>
8608
>
2300 - Underground Storage Tank Program
>
PR0234096
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/10/2024 1:41:09 PM
Creation date
11/6/2018 1:13:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0234096
PE
2333
FACILITY_ID
FA0003550
FACILITY_NAME
ALVAREZ FARMS INC
STREET_NUMBER
8608
Direction
W
STREET_NAME
SCHULTE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
13207012
CURRENT_STATUS
02
SITE_LOCATION
8608 W SCHULTE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SCHULTE\8608\PR0234096\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
10/13/2017 6:35:30 PM
QuestysRecordID
3679174
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNE& WATER RESOURCES CONTR�BOARD <br /> FORM 'B': UNDPKGROUND STORAGE TANK PR RAM <br /> PN <br /> TANK TANK PERMIT APPLICATION INFORMATIONm ; <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. = z <br /> MARK ONLY F-11 NEW PERMIT ❑ 3 RENEWALPERMIT 5 CHANGE OF INFORMATION ❑ 7 .E(�MANENTLY CLOSED TANK c <br /> ONE ITEM ❑2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE 8 TANK REMOV O <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: �.✓ JGL ' FARM TANK-YES/ NO ❑ N <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY I 76 co <br /> CO <br /> A. OWNERS TANKIDp B. MANUFACTURED BY: CJJ <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑2 PETROLEUM B. C. ❑ 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL ❑ 1 PRODUCT E]4 GASAHOL ❑ 5 JET FUEL 1:16 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY 95 UNKNOWN ❑2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED 8 C.A.S.X C.A.S.X: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOK A,B.C,A D <br /> A TYPE OF ❑ 1 DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALLED ❑ 4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑ I STEEL/IRON ❑2 STAINLESSSTEEL ❑ 3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK MATERIAL.. ❑5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑8 100%METHANOL COMPATIBLE FRP <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑ 99 OTHER_ <br /> ❑ <br /> C.INTERIOR 1 RUBBER LINED ❑2 ALKYD LINING ❑ 3 EPDXY LINING ❑4 PHENOLIC LINING <br /> LINING ❑ 5 GLASS LINING ❑6 UNLINED ❑ 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑99 OTHER <br /> D.CORROSION ❑ I POLYEiHLFHE WRAP ❑ 2 TAR OR ASPHALT ❑3 VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE ❑ 95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U i SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S I VISUAL CHECK P S 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P 8 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED B SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> C" /� <br /> O�U�NTY/M JURISDICTION M AGENCY N FACILITY IID M TTAANK IID/M/ <br /> CURRENT LOCAL AGENCY FACILITY 10 8 APPROVED BY NAME PHONE N WITH AREA CODE <br /> PERMIT NUMBER (fj E PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> -/ 9 <br /> CHECK I PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT 0 <br /> FORM B(6-29-58) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.