Laserfiche WebLink
! • <br /> PUBLIC HEALTH SERVICES ,o A° �o <br /> SAN JOAQI,IN COUNTY � � GA <br /> IOGI KHANNA KD,KP H. <br /> Health Officer q <br /> E.O. Box 2009 • (1601 East Hazelton Avenue) • Stockton, California 95201 <br /> c4ti F pR"� <br /> (209) 468-3400 <br /> rMPORTANI' DEADLINES FOR UNDERGROUND STORAGE TANKS <br /> California Code of Regulations(CCR) Title 23, Division 3, and <br /> California Health and Safety Code (H&S), Division 20, Chapter 6.7 <br /> Code of Federal Regulations (CFR), Subpart H, Part 280 <br /> December 22, 1990 All pressurized pipelines shall be equipped with automatic line leak detectors <br /> [California H&S Code, Section 25292(e)*]. <br /> ,duly 1, 1992 Independent testing organization approval required for all USTs, piping and other <br /> components for new installations[CCR, Article 3, Section 2631(b)*]. <br /> ,January 1, 1993 Inventory reconciliation shall not be used as part of non-visual monitoring for existing <br /> USTs where groundwater level is less than 20 feet below bottom of tank unless an <br /> approved Statistical Inventory Reconciliation method is being utilized. [CCR, Article <br /> 4, Section 2646 (b) and State `)Vater Resources Control Board "LG-123"]. <br /> `December 31, 1993 All petroleum UST owners or operators must show financial responsibility to ensure <br /> that there will be money to help pay for the costs of corrective action and third party <br /> liability caused by an unauthorized release from the UST(s). (40 CFR, Part 280.90; <br /> California H&S Code, Section 25292.2; and CCR Section 2802.2). <br /> December 22, 1998 USTs shall be equipped with a leak detection system that will shut off pump when a <br /> leak occurs [CCR, Article 4, Section 2643(d)*]. <br /> Manual tank gauging shall not be used for tanks with secondary containment or tanks <br /> greater than or equal to 1,001 gallons [CCR, Article 4, Section 2645(b)]. <br /> Inventory reconciliation shall not be used for monitoring any UST [CCR, Article 4, <br /> Section 2646(c)]. <br /> USTs containing hazardous substances (non-motor vehicle fuel) shall have secondary <br /> containment, [CCR, Article 6, Section 2662(a)*]. <br /> Steel tanks containing motor vehicle fuels shall have secondary containment or interior <br /> lining and exterior cathodic protection [CCR, Article 6, Section 2662 (b)*]. <br /> Overfill and spill prevention is required for all USTs [CCR, Article 6, Section <br /> 2663(a)*]. <br /> Secondary containment is required for all non-motor vehicle fuel piping. Secondary <br /> containment is required for motor vehicle fuel piping that is not fiberglass reinforced <br /> plastic or cathodically protected steel (CCR, Article 6, Section 2664*). <br /> A permit to upgrade or repair tank/fuel line system must be obtained from Public Health Services, <br /> Environmental Health Division. <br /> EH 23 088 8120192 <br /> 1 Division pf San Joaquin Counry Health(:are Jcmccs ��' <br />