Laserfiche WebLink
CL Properties, VI E37801.02B <br /> December 30, 1999 Page 5 <br /> Summary of Soil Vapor Sample Analytical Results, <br /> Sampling Date: December 13t , 1999 <br /> (All sam les collected at 5 feet below site rade) <br /> Sam le Location1 TPH-G I Chlorinated Solvents <br /> ' Soil Vapor Sample Analytical Results Results in /L <br /> SVl ND ND <br /> SV2 ND ND <br /> SV3 ND ND <br /> SV4 ND ND <br /> SV5 ND ND <br /> SV6 ND ND <br /> ' SV7 ND IND <br /> TPH-G= total petroleum hydrocarbons-gasoline range constituents; <br /> ' Chlorinated Solvents= Chloromethane, Vinyl Chloride, Bromomethane,Chloroethane, 1.1-Dichloroethene, <br /> Methylene chloride, trans- 1, 2-Dichloroethane, 1,1-Dichloroethane, cis- 1, 2- <br /> Dichloroethane,Chloroform,1,1,1 Trichloroethane,1,2-Dichloroethane,Benzene,Carbon <br /> Tetrachloride,Trichloroethene(TCE), 1,2-Dichloropropane,Bromodichloromethane,cis- <br /> 1,3- Dichloropropene, Toluene, trans- 1,3- Dichloropropene, 1,1,2 - Trichloroethane, <br /> Dibromochloroethane, Tetrachloroethene (PCE), Chlorobenzene, Ethylbenzene, m&p- <br /> Xylene,o-Xylene,Styrene,Bromoforml,1,2,2-Tetrachloroethane,l,3-DCB,1,4-DCB,and <br /> 1,2-DCB; <br /> µg/L= micrograms per liter; <br /> ND= not detected above laboratory detection limit. <br /> Note: Detection limits for reporting purposes are documented in the attached laboratory reports. <br /> 6.0 EVALUATION <br /> The following evaluations are based on the observations made in the field and the analytical results <br /> 1 from selected soil and groundwater samples. <br /> 6.1 Soil Vapor Assessment:Twining analyzed all seven soil vapor samples for the constituents <br /> of concern (COCs) including TCE, PCE and TPH-G. No reportable concentrations of the COCs <br /> were detected in any soil vapor sampling points. <br /> ' 7.0 CONCLUSIONS AND RECOMMENDATIONS <br /> Based on the work scope and findings described in this report the following conclusion is offered: <br /> • No evidence of a release of dry cleaner solvents(including TCE, and PCE)were detected in <br /> any of the soil vapor samples. <br /> Based on the findings, Twining does not recommend additional assessment regarding the adjacent <br /> and former dry cleaning facilities. <br />