My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SONORA
>
38
>
2300 - Underground Storage Tank Program
>
PR0503809
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2024 2:04:10 PM
Creation date
11/6/2018 2:06:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0503809
PE
2381
FACILITY_ID
FA0005982
FACILITY_NAME
MORTON PAINT CO
STREET_NUMBER
38
Direction
W
STREET_NAME
SONORA
STREET_TYPE
ST
City
STOCKTON
Zip
95203
CURRENT_STATUS
02
SITE_LOCATION
38 W SONORA ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SONORA\38\PR0503809\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
8/21/2017 5:07:02 PM
QuestysRecordID
3595881
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORN& WATER RESOURCES CONTR OARD <br /> FORM 'B': UNDERGROUND STORAGE TANK PRWRAM <br /> TANK PERMIT APPLICATION INFORMATION �1,� c' <br /> TANK COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. - = Z <br /> IO <br /> MARK ONLY ❑ 1 NEW PERMIT ❑3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑7 PERMANENTLYK <br /> ONE ITEM ❑ 2 INTERIM PERMIT [-] 4 AMENDED PERMIT ❑6 TEMPORARY TANK C�LLOSURE [:]8 TANK REMOVED tai PO <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: IM, OR S/ � FARM TANK-YES❑ N`O .� <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY <br /> A. OWNERS TANK ID# <br /> B. MANUFACTURED BY: G <br /> C. YEAR INSTALLEDD. TANK CAPACITY IN GALLONS: 9 a <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. D 1 M 13 VEHICLE FUEL ❑ 2 PETROLEUMB. C. ❑ 1 UNLEADED ❑ 2 LEADED ❑3 DIESEL <br /> [laCHEMICAL PRODUCT ❑ 4 OIL 1 PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> [:] 5 HAZARDOUS ❑ 80 EMPTY [:]95 UNKNOWN F12 WASTE ❑ 7 METHANOL OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF /D `e <br /> HAZARDOUS SUBSTANCE STORED 8 C.A.S.# /DO L eL�f u�` l;'*V*'�C.A.S.#: 1*1 <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOK A,B,C,&D <br /> A TYPE OF 0.1�80UBUEWAULED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM 2 SI LE WALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> 1 STEEUIRON ❑ 2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEEL CUD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑ 8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑99 OTHER <br /> ❑ 1 RUBBER UNED D 0LINING ❑3 EPDXY UNING ❑4 PHENOLIC LINING <br /> C. INTERIOR 5 GLASS LINING 6 UN NED 95 UNKNOWN <br /> LINING <br /> ❑ IS LINING MATERIAL COMPATIBLE WI 00 m% ❑YES ❑ NO ❑99 OTHER <br /> D. CORROSION ❑ I POLYETHLENEWRAP 2 TAR OR ASPHALT ❑3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑ 91 NONE ❑ 95 UNKNOWN 99 OTHER <br /> IV. PIPING INFORMA ION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S IVISUALCHECK P S 2 INVENTORY RECONCILIATION P 8 3VADOSE WELLS P 3 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P 8 7 PRESSURE TESTING P S 91 NONE P 8 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES [:] NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> aa 6 ° I v <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME PHONE N WITH AREA CODE <br /> 0315' <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> FORMB(6-29-68) THIS FORM MUST BE ACCOMPANI WY A FACILITY/SITE APPLICATION, FORM `A',UNLESS A a RENT FORMA' HASBEENFILED O <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.