My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1994-2010 (2)
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
STOCKTON
>
239
>
2300 - Underground Storage Tank Program
>
PR0231482
>
COMPLIANCE INFO 1994-2010 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:39:57 PM
Creation date
11/6/2018 2:38:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1994-2010
RECORD_ID
PR0231482
PE
2361
FACILITY_ID
FA0000720
FACILITY_NAME
MADSENS SUNRISE DAIRY
STREET_NUMBER
239
Direction
S
STREET_NAME
STOCKTON
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
25927805
CURRENT_STATUS
02
SITE_LOCATION
239 S STOCKTON ST
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\STOCKTON\239\PR0231482\COMPLIANCE INFO 1994-2010.PDF
QuestysFileName
COMPLIANCE INFO 1994-2010
QuestysRecordDate
9/25/2017 6:59:08 PM
QuestysRecordID
3647880
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
156
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0- <br /> Jan 23 06 08: 16p MIW Dotten 200533-2650 <br /> 533-2650 p. 2 <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: 0 Tank Manufacturer Industry Standard [I Professional Engineer <br /> El Other(Specify) <br /> Test Method Used: ❑Pressure vacuum El-Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Equipment Resolution: <br /> Tank N I Tank# Tank 4 Tank# <br /> Is Tank Exempt From Testing?' E]Yes Z No El Yes 0 No El Yes E]No 11 Yes 11 No <br /> Tank Capacity: 12000 <br /> Tank Material: DW Steel <br /> Tank Manufacturer- Unknown <br /> Product Stored: Diesel &Gas <br /> Wait time between applying <br /> pressure/vacuum/water and None <br /> starting test: <br /> Test Start Time: 12:30 <br /> Initial Reading(Rt)- 20" we <br /> Test End Time: 13:00 <br /> Final Reading(RF): 20"we <br /> Test Duration: 30 min <br /> Change in Reading(RF-R,): 0.00 <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: Z Pass El Fail Ll Pass [:] Fail [I Pass El Fail 0 Pass El Fail <br /> Was sensor removed for testing? ❑Yes M No[] NA 0 Yes[]NoE]NA [:]YesEl No[:]NA 0 Yes[]NoE]NA <br /> Was sensor properly replaced and E Yes El NoO NA [:]Yes E]NoE]NA El YesEl NoE]NA El Yes 0 No[]NA <br /> verified functional after testing? <br /> Com meats—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> The annular space serves all three compriments of this tank <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {California Code of Regulations,Title 23. Section 2637(a)(6)1 <br />