My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1985-1994 (2)
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
STOCKTON
>
320
>
2300 - Underground Storage Tank Program
>
PR0231481
>
BILLING 1985-1994 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2021 10:23:37 PM
Creation date
11/6/2018 2:44:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1985-1994
RECORD_ID
PR0231481
PE
2381
FACILITY_ID
FA0003931
FACILITY_NAME
RIPON MILLING CO
STREET_NUMBER
320
Direction
S
STREET_NAME
STOCKTON
STREET_TYPE
AVE
City
RIPON
Zip
95366
APN
25929015
CURRENT_STATUS
02
SITE_LOCATION
320 S STOCKTON AVE
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\STOCKTON\320\PR0231481\BILLING 1985-1994.PDF
QuestysFileName
BILLING 1985-1994
QuestysRecordDate
8/29/2017 6:09:53 PM
QuestysRecordID
3610438
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA • al' ••-• <br /> STATE WATER RESOURCES CONTROL BOARD w W u u <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION • FORM B <br /> A4 nan N•• <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ONSITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ e TEMPORARY TANK CLOSURE [TANK REMOVED U, I <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: 3Ze) <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN 1_ <br /> A. OWNER'S TANK I.D.# Z B. MANUFACTURED BY: 16 <br /> K <br /> C. DATE INSTALLED(MOIDAY/YEAR) ' l:J / D. TANK CAPACITY IN GALLONS: <br /> anpr <br /> II.TANKCO NTS IFA-1 IS MARKED.COMPLETE ITEM C. <br /> I MOTOR VEHICLE FUEL ❑ 4 OIL B. C. ❑ 1flUNLEADED REGULAR 3 DIESEL ❑ g AVIATION GAS <br /> IUM <br /> q 4 GASAHOL 7 METHANOL <br /> 2 PETROLEUM❑ 3 CHEMICAL PRODUCT O 90 EMPTY ❑ 1 PRODUCT O 2 LEPREUNLEADED ❑❑ 5 JETFUEL ❑ <br /> 95 UNKNOWN 2 WASTE 2 LEADED 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,5,AND C,AND ALL THAT APPLIES IN BOX D AND <br /> [:] 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> A. TYPE OF R <br /> SYSTEM Iii Z SINGLE WALL F74 SECONDARY CONTAINMENT (VAULTEDTANK) ❑ 99 OTHER <br /> rn 1 BARE STEEL [-] 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEELCLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ <br /> B. TANK 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 9 100% METHANOL COMPATIBLE W/FRP <br /> (PrimgryTank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ W OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR ❑ 5 GLASS LINING ❑ 6 UNLINEDUNKNOWN ❑ 99 OTHER <br /> LINING <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES_ NO_ <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE 6 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> 7 <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 6 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION F-] 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ MONRORING ❑ OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUNDWATER MONITORING <br /> ❑ 6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING DRE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/�Y/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES O NO <br /> T SUBSTANCE R EMAINING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME GATE <br /> (PRINTED A SIGNATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TANK# <br /> STATE I.D.# 75F5 FT-M 7,1 FLN[oklz; <br /> PERMITNUMBER PERMIT APPROVED SY/DATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION•FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br /> FORME (12-91) • ��Y���, V / � FOR00NSR6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.