My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2000-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
STOCKTON
>
445
>
2300 - Underground Storage Tank Program
>
PR0529502
>
COMPLIANCE INFO 2000-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:05 PM
Creation date
11/6/2018 2:46:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2009
RECORD_ID
PR0529502
PE
2381
FACILITY_ID
FA0019572
FACILITY_NAME
NEWARK SIERRA PAPERBOARD CORP
STREET_NUMBER
445
STREET_NAME
STOCKTON
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14523004
CURRENT_STATUS
02
SITE_LOCATION
445 STOCKTON ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\STOCKTON\445\PR0529502\COMPLIANCE INFO 2000-2009.PDF
QuestysFileName
COMPLIANCE INFO 2000-2009
QuestysRecordDate
8/22/2017 5:40:07 PM
QuestysRecordID
3600119
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 • <br />X. AIR MONITORING <br />Air monitoring should be conducted with instruments selected to measure contaminants that <br />employees may be exposed to. Measurements should be taken within the breathing zones of workers. <br />If action levels are reached for a 1 -minute reading, appropriate action must occur. <br />A. OASES AND VAPORS <br />(a) Action Levels for "known contaminants" should be based upon the contaminants <br />Permissible Exposure Level (PEL) or Threshold Limit Values (TLVs). <br />(b) Action levels for unknown contaminants are based upon the following: <br />HNu or OVA Measurements in Breathing Zone <br />Reading for 1 minute <br />Background Level D <br />>0-5 ppm above background Level C <br />5-500 ppm above background Level B <br />500-1000 ppm above background Level A <br />Comments: <br />L:150000\50441\WP150441k27.doc 13 <br />Action Level <br />Instrument & <br />Frequency/ <br />(a)(b) Above <br />Background <br />Date of <br />Calibration <br />Duration of Air <br />(BreathingZone) <br />Calibration <br />Gas Standard <br />Monitoring <br />fiction <br />HNU - daily <br />100 ppm <br />periodically <br />greater than <br />Introduce <br />isobutylene <br />during <br />background <br />engineering controls <br />excavation <br />(i.e., blower fans <br />and sampling <br />(Level D) <br />>5 ppm <br />Don respirator <br />(Level C) <br />Leave area (Level C) <br />Upgrade to Level B <br />Upgrade to Level A <br />(a) Action Levels for "known contaminants" should be based upon the contaminants <br />Permissible Exposure Level (PEL) or Threshold Limit Values (TLVs). <br />(b) Action levels for unknown contaminants are based upon the following: <br />HNu or OVA Measurements in Breathing Zone <br />Reading for 1 minute <br />Background Level D <br />>0-5 ppm above background Level C <br />5-500 ppm above background Level B <br />500-1000 ppm above background Level A <br />Comments: <br />L:150000\50441\WP150441k27.doc 13 <br />