My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SWAIN
>
1211
>
2300 - Underground Storage Tank Program
>
PR0232404
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2024 4:48:03 PM
Creation date
11/6/2018 3:09:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0232404
PE
2381
FACILITY_ID
FA0003879
FACILITY_NAME
CITY OF STOCKTON FIRE STATION #11
STREET_NUMBER
1211
Direction
E
STREET_NAME
SWAIN
STREET_TYPE
RD
City
STOCKTON
Zip
95210
APN
09405009
CURRENT_STATUS
02
SITE_LOCATION
1211 E SWAIN RD
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\S\SWAIN\1211\PR0232404\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
8/14/2017 7:14:25 PM
QuestysRecordID
3577916
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
► STATE OFCALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION- FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM <br /> MARK ONLY 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ONSITE <br /> ONE ITEM 2 INTE IM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ B TANK REMOVED A I <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: E S / 1/�� <br /> V <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN � <br /> A. OWNER'S TANK I.D.# / B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAYNEAR) �.2_ D. TANK CAPACITY IN GALLONS: T� <br /> II.TANK CONTENTS FA--p IS MARKED,COMPLETE ITEM C. C! <br /> A. 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C. ❑ 1aUREGULAR N FADEDrL4 <br /> SEL <br /> ❑ 6 AVIATION GAS <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY �RODUCT 1b PREMIUM AHOL 7 METHANOL <br /> ❑ UNLEADED FUELO 3 CHEMICALPRODUCT ❑ 85 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED HER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTE NAME OF SUBSTANCE STORED C.A.S.# <br /> III. TANK CONSTRUCTION MA ONE ITEM ONLY IN BOXES A.S.AND C,AND ALL THAT APPLIES IN BOX D AND <br /> A. TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> R GU <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTEDTANK) ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEELCLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE WIFRP <br /> (PrImaryTank) ❑ 9 BRONZE ❑ 1 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBE R LINED ❑ 2 AL YD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIORLIN ❑ 5 GLASS LINING ❑ 6 UNLI D ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IS LINING MATERIAL COMPATIBLE WITH 100% M ANOL4 YES_ NO_ <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE F7 95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION CIRCLE A IFABOVEGROUNDOR U IF UND GROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SECTION A U 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A V SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN <br /> A U 99 OTHER <br /> C. MATERIAL AND A U 1 SAFE STEEL A U 2 STAINLESS STEEL U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U S ALUMINUM A U 6 CONCRETE U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U g GALVANIZED STEEL A U 10 CATHODIC PROTECTIO A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑ 1 A ITOMATIC LINE LEAK DETECTOR ❑ 2 LINETIGHTN STESTING ❑ 3 MONITORING ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK X2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> 8 TANK TESTINGem 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ETI AT DATE LAST USED(MO/ AY/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING GALLONS IN <br /> MATERIAL? YES [:] NO❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANT'S NAME <br /> (PRINTED 6 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> STATE 104COUNTY# JURISDICTION# FACILITY# TANK# <br /> PERMIT NUMBERPERMIT APPROVED BYIDATE PERMIT EXPIRATION DATE <br /> FORM B (7-91) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION•FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FORBN4&RS <br /> 0 Lo- lD - 73 <br />