Laserfiche WebLink
' Page 1 of 1 <br /> ' Table 7 <br /> Hydraulic Properties Determined from Aquifer Testing <br /> ' ARCO Service Station No 4932 <br /> 16 East Harding Way <br /> Stockton,California <br /> ' Saturated Hydraulic Properties <br /> Thickness Analysis Transmissivity Hydraulic Conductivity Storativity <br /> Well (feet) Method (ft2/min) (gpd/ft) (cm/sec) <br /> EW-1 167 Theis(Recovery) 013 1,400 0 004 <br /> MW-1 1161 Cooper-Jacob 031 3,300 0 014 003 <br /> Theis(Recovery) 078 8,400 0 034 <br /> MW-4 11 24 Cooper-Jacob Oil 1,200 0 005 0 02 <br /> Theis(Recovery) 020 2,200 0 009 <br /> MW-6 11 3 Cooper Jacob 0 50 5,400 0 023 003 <br /> MW-7 1095 Cooper-Jacob 046 5,000 0 021 003 <br /> Theis(Recovery) 100 11,000 0 046 <br /> ' Geometric Mean 034 3,600 0 014 0 03 <br /> Notes <br /> ftp/min= square feet per minute <br /> gpd/ft= gallons per day per foot <br /> cm/sec= centimeters per second <br /> 1 <br /> r <br /> ' 1 1ARC0149321Reportsllnvestigation TableslTable 7 <br />