Laserfiche WebLink
4ge4of5 <br /> Table 1 - <br /> Groundwater Elevation and Analytical Data <br /> Former ARCO Service Station$4932 <br /> 16 E Harding Way Stockton GA <br /> Well -Depth Groundwater_ LPH Groundwater Ethyl Xylenes R/ItBE <br /> Welt r Date Elevation , to Water Elevation Thickness Elevation TPHg Benzene Toluene benzene (total) (802018260) DO <br /> Number Sampled _ (R,MSL) (it,TOC) (ft,-MSL) (ft) Change(It) (ppb) (ppb) (ppb) (ppb) (Ppb) (ppb) (W-) <br /> DMW 1 4/11/2002 P 1198 2810 1612 0 00 <500 96 <5 0 <5 0 <50 2301140 - <br /> 07/12/02 P 2925 1727 000 115 55 <0 50 <0 50 <0 50 <0 50 72/64 27 <br /> 11/20/02 P 31 64 -1966 000 2 39 <50 076 0 63 <0 50 1 6 18/21 016 <br /> 01/30/03 - - - - Well unable to be sampled located in construction area <br /> 04/28103 P 3020 -1822 000 — <50 <0 50 <0 50 <0 50 <0 50 13 274 <br /> DMW-2 07/12/02 P 11 10 28 36 -1726 000 - <60 1 0 16 0 62 2 0 13/85 2 8 <br /> 11/20/02 P 30 84 1974 0 00 248 <50 <0 50 <0 50 <0 50 12 41 164" 327 <br /> 01/30/03 P 3004 1894 000 0 80 <50 <0 50 <0 50 <0 50 <0 50 40/33 521 <br /> 04/28/03 P 2933 -1823 000 0 71 <50 <0 50 <0 50 <0 50 <0 50 076 175 <br /> DMW-3 07/12/02 P 1149 2894 -1745 000 90" <0 50 13 <0 50 10 160/140 27 <br /> 11/20/02 P 3147 -1998 0 00 2 53 <50 <0 50 0 63 <0 50 16 14116 157 <br /> 01/30/03 P 30 70 1921 0 00 0 77 <50 <0 50 <0 50 <0 50 065 32/37 435 <br /> 04/28/03 P 2998 -1849 000 072 <50 <0 50 <0 50 <0 50 <0 50 5 9 313 <br /> EW 1 4/11/2002 P 1183 2795 -1612 000 - <200 000 9,900 40,000 4,700 24,000 550,0001520,000 - <br /> 07/12/02 P 29 04 -1721 000 109 350,000 13,000 49 000 6 100 34 000 320 0001460 000 2 7 <br /> 11/20/02 NP 3147 1964 000 -243 Not sampled LPH sheen present <br /> 01/30/03 P 2930 1747 000 217 220,000 8,000 31,000 4 400 23 000 140 0001200 000 083 <br /> 04/28/03 P 2958 -1775 000 -0 28 Well unable to be sampled connected to remedial system <br /> EW 2 07/12/02 P 11 22 2851 -1729 000 <50,000 <500 <500 <500 <500 56,000165 000 2 8 <br /> 11/20/02 P 3120 -1998 000 269 45 000 2 <100 <100 <100 <100 71,000/90,000 4 000 003 <br /> 01/30/03 P 30 45 1923 0 00 075 12,0002 <50 <50 <50 <50 52 000161000 4 <br /> 04!26103 P 2972 -1850 000 073 51,000, <500 <500 <500 <500 55,000 1 52 <br /> EW-6 11/20/02 P NS 31 07 000 - 28,000 390 1,500 1 200 6200 440/280 0 43 <br /> 01/30/03 P 2973 - 0 00 26,0150' 1 800 2,500 11500 6 200 7201600 0 83 <br /> 04/28/03 P 2920 -- 0 00 - Well unable to be sampled connected to remedial system <br /> QCTB 04128103 — — — -- <50 <0 50 <0 50 <0 50 <0 50 <0 50 <br /> Project!ARCO/49321ReportslTables/gwtables4932 <br />