Laserfiche WebLink
J <br /> NIST/NVLAP Lao Coda No.102116-0 <br /> Caldomla ELAP Certificate No 1269 <br /> New York EIRP CerMmrate No.11017 <br /> Hygeia Laboratories Inc. <br /> 82 W.Sierra Moore BIW <br /> Sierra Madre,CA 91024-2434 Bulk Sample Analysis Summary <br /> (626)3554711 (626)3554497 Fm Analytical Method: EPA 600/R-93/116 Point Count-1000 Points <br /> September 23, 2007 <br /> Mr.Dean Mochde Hyaeia ReferenceNo.: 00053 07 0189 <br /> ATC Env.Mgmt.(Sacramento) Samples Analyzed: 1 Date Collected: August 23,2007 <br /> 3600 Madison Ave.Suite 64 Sampler: J.Silva Date Received: August 27,2007 <br /> North Highlands,CA 95660 1 Sample Condition: Acceptable Date Analyzed: September 14,2007 <br /> Client Reference: Task 53001 35.75376.5663 John Deers <br /> Client Sample ID Sample Description Detection Gravimetric Reduction Analytical Results <br /> Hygeia Sample ID Comments Limit <br /> 36 Drywall/joint compound 0.04% 12%organic <0A%chrysotile <br /> 1098030p 46%add soluble <br /> Microscopist- Guillermo Hernandez <br /> The analyses of the samples in this report were performed using gravimemc matrix reduction and polarized light microscopy(PLM) in accordance with the EPA method <br /> 600/R-93/116 July 1993.The asbestos concentration was determined using the semi-quantitative point court method. On a per sample basis,the accuracy and precision a <br /> point mum results are not known.The result should lie within the statistical limits of variability calculated for standard reference samples routinely analyzed in the laboratory <br /> using the print count method The limit of detection for this analytical method is 0.25 percent using 400 points and 0.10 percent using 1000 points(visual area estimates). <br /> Hygala recommends masmi scion electron microscopy(TEM)analysis on organically bound bulk materials(eg.,vinyl floor tile,mastic,roofing malenals,pint compounds) <br /> when PLM analysis shows undetectable quanfities of asbestos. These materials often contain milled asbestos with fiber diameters and lengths too small to be resolved by <br /> the PLM and the analysis may yield a false negative result. <br /> Hygeia Laboratories Inc.is accredited under the NIST/NVLAP program for asbestos in bulk material by polarized light microscopy and the State of California for asbestos <br /> analysis. <br /> Hygma Laboratories Inc.and its personnel shall not be liable for any misinformation provided to us by the client regarding these samples or for any misuse or interpretation <br /> information supplied by us. Liability shall extend to providing replicate analyses only. This report must not be used to claim product endorsene nt by NVLAP or any agency <br /> ofthe 11S Government. Hygeia will retain samples for a period of three months unless otherwise specified. This report relates only to samples submitted and analyzed. Th <br /> report may not be reproduced except for in full,without the written approval of this laboratory. <br /> Please feel free to contact Hy/grim regarding any questions about these results,this report,or the analytical methods employed. <br /> Arturo Cases-Supervisor of Optical Microscopy <br /> at Hygeela Ref No.: 00053070189 Page 1 of 7 <br />