My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CARNEGIE
>
555
>
2200 - Hazardous Waste Program
>
PR0507070
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2018 10:43:28 AM
Creation date
11/6/2018 8:38:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0507070
PE
2220
FACILITY_ID
FA0007703
FACILITY_NAME
ADVANCED INTERCONNECT TECHNOLOGIES
STREET_NUMBER
555
STREET_NAME
CARNEGIE
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
22119064
CURRENT_STATUS
02
SITE_LOCATION
555 CARNEGIE ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS3\222IAError\IAError\C\CARNEGIE\555\PR0507070\COMPLIANCE INFO\COMPLIANCE INFO.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
346
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OR <br />August 31, 2001 <br />Advanced Interconnect Tech. <br />Quality Control - Inorganic <br />Lab ID : STK133833 <br />Customer: 3-3147 <br />Definitions <br />Blank Method Blank - Prepared to verify that the preparation process is not contributing contamination to the samples. <br />LCS Laboratory Control Standard/Sample - Prepared to verify that the preparation process is not affecting analyte <br />recovery. <br />MS/MSD Matrix Spikes - A random sample is spiked with a known amount of analyte. The recoveries are an indication o <br />how that sample matrix affects analyte recovery. <br />ICV Initial Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br />ICB Initial Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br />CCV Continuing Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br />CCB Continuing Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br />ND Non -detect - Result was below the DQO listed for the analyte. <br />DQO Data Quality Objective - This is the criteria against which the quality control data is compared. <br />STK133833: Quality Control Page 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.