Laserfiche WebLink
`/ <br />March 20, 2001 <br />Advanced Interconnect Tech. <br />Quality Control - Inorganic <br />FWA <br />Lab ID : STK130995 <br />Customer: 3-3147 <br />Constituent <br />Method <br />Date/ID <br />Type <br />Units <br />Cone. <br />QC Data <br />DQO <br />Yote <br />Metals <br />Nickel <br />200.7 <br />03/12/2001:8 <br />02 -CCB <br />mg/L <br />ND <br /><O.OI <br />02-CCV <br />mg/L <br />1.000 <br />100% <br />90-110 <br />03 -CCB <br />mg/L <br />ND <br /><0.01 <br />03-CCV <br />mg/L <br />1.000 <br />100% <br />90-110 <br />Silver <br />3010A <br />03108/2001:A207 <br />Blank <br />mg/L <br />ND <br /><0.01 <br />LCS <br />mg/L <br />0.8000 <br />104% <br />85-115 <br />MS <br />mg/L <br />0.8000 <br />70.2% <br />75.125 <br />435 <br />(SP 101832-01) <br />MSD <br />mg/L <br />0.8000 <br />50.4% <br />75-125 <br />435 <br />FDS <br />mg/L <br />0.8000 <br />102% <br />75-125 <br />MSRPD <br />mg/L <br />33.0% <br />520.0 <br />440 <br />200.7 <br />03/12/2001:6 <br />02 -CCB <br />mg/L <br />ND <br /><0.01 <br />02-CCV <br />mg/L <br />1.000 <br />100% <br />90-110 <br />03 -CCB <br />mg/L <br />ND <br /><0.01 <br />03-CCV <br />mg/L <br />1.000 <br />101% <br />90.110 <br />Zinc <br />3010A <br />03/08/2001:A207 <br />Blank <br />mg/L <br />ND <br /><0.02 <br />LCS <br />mg/L <br />0.8000 <br />107% <br />85-115 <br />MS <br />mg/L <br />0.8000 <br />101% <br />75-125 <br />(SP 101832-01) <br />MSD <br />mg/L <br />0.8000 <br />97.6% <br />75-125 <br />PDS <br />mg/L <br />0.8000 <br />102% <br />75-125 <br />MSRPD <br />mg/L <br />3.0% <br />520.0 <br />200.7 <br />03/12/2001:8 <br />02-CCBmg/L <br />ND <br /><0.02 <br />02-CCV <br />mg/L <br />0.5000 <br />104% <br />90-110 <br />03 -CCB <br />mg/L <br />ND <br /><0.02 <br />03-CCV <br />mg/L <br />0.5000 <br />103% <br />90-110 <br />Wet Chem <br />Cyanide, Total <br />450OCNCE <br />03/12/2001.A210 <br />Blank <br />mg/L <br />ND <br /><0.01 <br />LCS <br />mg/L <br />0.1000 <br />111% <br />78-119 <br />MS <br />mg/L <br />0.05000 <br />79.4% <br />85-123 <br />435 <br />(SP 101822-01) <br />MSD <br />mg/L <br />0.05000 <br />76.6% <br />85-123 <br />435 <br />MSRPD <br />mg/L <br />0.0014 <br />50.0100 <br />Cyanide <br />450OCNCE <br />03/1312001:A <br />00 -CCB <br />mg/L <br />ND <br /><0.01 <br />00-CCV <br />mg/L <br />0.1000 <br />106% <br />90-110 <br />01 -CCB <br />mg/L <br />ND <br /><0.01 <br />Ol-CCV <br />mg/L <br />0.1000 <br />110% <br />90-110 <br />E:cp'anations <br />435 Sample matrix may be affecting this analyte. Dara was accepted based on the LCS or CCV recovery. <br />440 Sample nonhomogeneity may be affecting this analyte. Data was accepted based on the LCS or CCV <br />recovery. <br />Definitions <br />Blank Method Blank - Prepared to verify that the preparation process is not contributing contamination to the samples. <br />LCS Laboratory Control Standard/Sample - Prepared to verify that the preparation process is not affecting analyte <br />recovery. <br />MS/MSD Matrix Spikes - A random sample is spiked with a known amount of analyte. The recoveries are an indication o <br />how that sample matrix affects analyte recovery. <br />PDS Post Digestion Spike (ICP/GFAA) <br />CCV Continuing Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br />Definitions are continued on next page... <br />STK130995: Quality Control Page 2 <br />