Laserfiche WebLink
Environmental Health Department <br />Small Quantity Hazardous Waste Generator Inspection Report <br />Date: <br />November 01, 2017 <br /> Facility Address: <br /> 3011 S EL DORADO ST, STOCKTON <br /> Facility Name: <br /> AP AUTO HOSPITAL <br />Treatment, Transport and Disposal <br /> 208 □ V □ R □ COSFailure of laboratory to comply with hazardous waste treatment requirementsHSC 25200.3.1(c) <br /> 209 □ V □ R □ COSFailure to remove all hazardous waste from tanks, containers and containment upon facility closureCCR 66262.34(d)(2) <br />Preparedness and Prevention <br /> 301 □ V □ R □ COSFacility not maintained to minimize the release of a hazardous wasteCCR 66262.34(d)(2) <br /> 302 □ V □ R □ COSFailed to maintain required emergency equipmentCCR 66262.34(d)(2) <br /> 303 □ V □ R □ COSFailed to maintain all communication or alarm systems, spill control, or decontamination equipmentCCR 66262.34(d)(2) <br /> 304 □ V □ R □ COSFailed to maintain adequate aisle space for unobstructed response to emergenciesCCR 66262.34(d)(2) <br />Container Management <br /> 401 □ V □ R □ COSFailed to store hazardous waste in a container that is in good conditionCCR 66262.34(d)(2) <br /> 402 □ V □ R □ COSFailed to store hazardous waste in a compatible containerCCR 66262.34(d)(2) <br /> 403 □ V □ R □ COSFailed to keep hazardous waste containers closed except when adding or removing hazardous wasteCCR 66262.34(d)(2) <br /> 404 □ V □ R □ COSFailed to inspect hazardous waste storage areas at least weeklyCCR 66262.34(d)(2) <br /> 405 □ V □ R □ COSFailed to manage incompatible wastes in containers properlyCCR 66262.34(d)(2) <br /> 406 □ V □ R □ COSContaminated container not marked with date emptied or managed within one year of being emptiedCCR 66261.7 <br /> 407 □ V □ R □ COSSatellite accumulation container not located near point of generation or under control of operatorCCR 66262.34(e)(1)(A) <br /> 408 □ V □ R □ COSSatellite accumulation exceeded 55 gallons of HW (or one quart of acutely HW) per waste streamCCR 66262.34(e)(2) <br />Tank Management <br /> 501 □ V □ R □ COSNo overfill prevention device on continuously fed hazardous waste tankCCR 66262.34(d)(2) <br /> 502 □ V □ R □ COSTank system inspections of discharge systems, monitoring equipment, and tank levels not done dailyCCR 66262.34(d)(2) <br /> 503 □ V □ R □ COSTank system inspections of construction materials, fixtures, and surrounding areas not done weeklyCCR 66262.34(d)(2) <br /> 504 □ V □ R □ COSFailed to maintain at least two feet of freeboard in uncovered tank with no secondary containmentCCR 66262.34(d)(2) <br /> 505 □ V □ R □ COSFailed to completely label stationary hazardous waste tanksCCR 66262.34(f) <br />Labeling and Storage <br /> 601 ■ V □ R □ COSStored hazardous waste onsite greater than 180 daysCCR 66262.34(d) <br /> 602 □ V □ R □ COSStored satellite accumulated waste on site longer than one year or 180 days after fill dateCCR 66262.34(e)(1)(B) <br /> 603 □ V □ R □ COSFailed to mark initial accumulation start date on satellite containersCCR 66262.34(e)(1)(C) <br /> 604 □ V □ R □ COSFailed to mark satellite containers with date filled within three daysCCR 66262.34(e)(3) <br /> 605 □ V □ R □ COSFailed to completely label containers or portable tanks of hazardous wasteCCR 66262.34(f) <br /> 606 □ V □ R □ COSFailed to meet lead acid battery storage requirements for hazardous waste management exemptionCCR 66266.81(a)(3) <br /> 607 □ V □ R □ COSDamaged lead acid batteries not properly managed and labeledCCR 66266.81(b) <br /> 608 □ V □ R □ COSFailed to properly manage used oil and fuel filtersCCR 66266.130 <br /> 609 □ V □ R □ COSFailed to meet requirements for claimed excluded recyclable materialsHSC 25143.2, 25143.9 <br /> 610 □ V □ R □ COSStored acutely or extremely hazardous waste onsite greater than 90 daysCCR 66262.34(b)(1) <br /> 611 □ V □ R □ COSFailure of laboratory to comply with hazardous waste accumulation area requirementsHSC 25200.3.1(b) <br />Page 2 of 4 <br />FA0023883 PR0541673 SC001 11/01/2017 <br />EHD 22-01 Rev. 09/22/16 Small Quantity Hazardous Waste Generator OIR <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com