My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
17100
>
2200 - Hazardous Waste Program
>
PR0220072
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2019 2:32:45 PM
Creation date
11/6/2018 8:39:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO_PRE 2019
FileName_PostFix
PRE 2019
RECORD_ID
PR0220072
PE
2247
FACILITY_ID
FA0000210
FACILITY_NAME
CARPENTER CO
STREET_NUMBER
17100
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19812004
CURRENT_STATUS
02
SITE_LOCATION
17100 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS3\222IAError\IAError\H\HARLAN\17100\PR0220072\COMPLIANCE INFO 1984 - 2016.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
503
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FEBCO SPECIFICATION SHEET NO. 825 (21/2"-10 <br /> Model 825 (21/2" through 10") <br /> Reduced Pressure Backflow Preventer <br /> For High Hazard Service <br /> a ea 7'e4e� Metre <br /> �Izo.cfed ens 7 - <br /> ❑ Revise and Resu'- <br /> CM1ecking is ontc�(y tenfemr.ISIA rM1c �e„oma .n. <br /> Ilse OrO1P.Cf Tn{ <br /> COl lfacnpp <br /> nnerL G...I, .- ,.V <br /> d setev io lire faJ ! - <br /> a i fir cocrd <br /> r � <br /> 4- <br /> I, <br /> •Shown with optional O S&Y gate valves. <br /> Features and discharge to maintain the zone at least 2 PSI lower <br /> • Ultimate mechanical protection of potable water than the inlet pressure: thus preventing the contamination <br /> of the supply. <br /> against hazards of cross connection contamination. <br /> •Meets all specifications of AWWA, ASSE, CSA Materials <br /> and USC Foundation for Cross Connection Control <br /> and Hydraulic Research and UL classified for fire Bronze bodies and trim are used on 825 units 2”and smalle <br /> line service 825 2-112"through 10" are cast iron bodies with bronze trim <br /> • Documented flow curves established by University and have internal epoxy coating standard. <br /> of Southern California Foundation for Cross Nitrile seat discs and fabric reinforced nitrile diaphragms. <br /> Connection Control and Hydraulic Research. Gate valves supplied are non-rising stem. OS&Y gate valvE <br /> '.: •Simple service procedures. All internal parts and resilient wedge gates valves optional. <br /> serviceable in line. Specifications <br /> • Double diaphragm differential relief valve. <br /> The reduced pressure backflow preventer shall consist of <br /> • Independent spring loaded "Y"type check valves. two separate spring loaded "Y" type check valves and one <br /> • Replaceable seats on both check valves and differential relief valve having two diaphragms separated b <br /> differential relief valve a spacer. This device shall automatically reduce the <br /> pressure in the"zone" between the check valves. Should <br /> •Corrosion resistant internal parts the differential between the upstream and the zone to the <br /> unit drop to 2 PSI, the differential relief valve shall open anc <br /> Description maintain the proper differential <br /> The Febco 825 RP Device consists of two Both check valves and the differential relief valve shall be <br /> independent"Y" pattern spring loaded check valves. a constructed so they may be serviced without removing the <br /> differential pressure relief valve mounted between the two device from the line. <br /> checks, and three lest cocks. An inlet shutoff valve with a Backflow preventers 2" and smaller shall have bronze <br /> fourth lest cock and an outlet shutoff valve are added to bodies and trim. 2-112" and larger shall have cast <br /> make a complete and serviceable assembly. In normal iron bodies with internal epoxy coating and bronze trim. <br /> operation. the check valves are open with the pressure Rated to 175 PSI working pressure and water temperature <br /> between the checks, called the zone, being maintained from 32eF to 140eF. <br /> at least 5 PSI lower than the inlet pressure and the relief The device shall meet the requirements of ASSE Standard <br /> valve is maintained closed Should abnormal conditions 1013. AWWA Standard C506-78. and USC Foundation for <br /> arise under backflow, the differential relief valve will open Cross Connection Control and Hydraulic Research. <br />
The URL can be used to link to this page
Your browser does not support the video tag.