Laserfiche WebLink
Roy F. Weston, Inc- - Stockton Labo_rator_v <br /> Final Report Faae: 1 <br /> Client : LODI METAL TECH. , INC_ Date Sam Fled.: 3/12/_199.1 <br /> Sample ID: LODI METAL TECH SPL Date Recei-%ed: 3/14/1.991. <br /> Matrix: SOLID QC Batch # : I032791PS2 <br /> Lab ID: 858846-SA-A Date Analyzed: 3/27/1991 <br /> Project #k: L90112 . LF # : 10509 Data Reported.: 4/03/1.991 <br /> Starting Depth: 0 . 00 Ending Depth: 0 . 00 <br /> Test Description: TCLP Extractable Metals Analysis <br /> P,eporting <br /> Analyte Result* Limit ?7nits Method <br /> Cadmium 0 . 25 0 . 10 ma/_L <br /> Selenium ND 0 . 50 mg/L <br /> Tested By : JMC <br /> Validated By: TLH <br /> * ND indicates a compound was not detected at a concentration le--el <br /> greater than the reporting limit - <br />