My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KELLY
>
214
>
2200 - Hazardous Waste Program
>
PR0517911
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/26/2024 2:41:56 PM
Creation date
11/6/2018 8:40:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO_PRE 2019
FileName_PostFix
PRE 2019
RECORD_ID
PR0517911
PE
2227
FACILITY_ID
FA0010183
FACILITY_NAME
SPACERAK
STREET_NUMBER
214
Direction
S
STREET_NAME
KELLY
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04906026
CURRENT_STATUS
01
SITE_LOCATION
214 S KELLY ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\222IAError\IAError\K\KELLY\214\PR0517911\COMPLIANCE 2000 - 2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
523
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Yes No Comment <br /> Contingency Plan and Emergency Procedures (cont. ) <br /> Chapter 15, Article 4 <br /> If an emergency occurred at this facility, did <br /> the EC immediately: [66265.56-] <br /> (a) Activate alarm systems and notify <br /> appropriate response agencies? _ <br /> (b) Identify the character, source, amount and <br /> areal extent of released materials? _ <br /> (c) Asses the possible direct and indirect <br /> hazards from the release, including gases and <br /> run-off of fire fighting materials? _ <br /> (d-) When assessment determines that the release <br /> cxxild threaten human health or the environment <br /> outside the facility: <br /> (1) Report his findings to appropriate <br /> authorities if it may be advisable to <br /> evacuate the local area, and remain on call <br /> to help authorities decide? <br /> (2-) Immediately notify the State Office of <br /> Emergency Services with a report including <br /> required information? <br /> (e) During emergency, does EC take all <br /> reasonable measures to minimize release? _ <br /> (f) If the facility had to stop operations to <br /> respond, does the EC monitor all appropriate <br /> equipment? _ <br /> (g) After the emergency, does the EC immediately <br /> provide for the TSD of recovered or contaminated <br /> material resulting from the release? — <br /> (h-) Does the EC ensure that in the affected <br /> areas of the facility: <br /> (1) Wastes incompatible with released <br /> material are not handled until after clean-up <br /> is couplete? — — <br /> (2) All emergency equipment listed in <br /> contingency plan is clean and fit for use <br /> before operations resume? — <br /> (i) Does the generator notify the Department, <br /> state and local authorities that 66265.56(h) is <br /> complied with before resuming operations in <br /> affected areas? _ <br /> (j) If the contingency plan was implemented, did <br /> the generator record details of the incident in <br /> the operating record and, within 15 days, submit <br /> a written report to the Department? — <br /> Revised 7/15/91 Page 24 <br />
The URL can be used to link to this page
Your browser does not support the video tag.