My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KELLY
>
214
>
2200 - Hazardous Waste Program
>
PR0517911
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/26/2024 2:41:56 PM
Creation date
11/6/2018 8:40:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO_PRE 2019
FileName_PostFix
PRE 2019
RECORD_ID
PR0517911
PE
2227
FACILITY_ID
FA0010183
FACILITY_NAME
SPACERAK
STREET_NUMBER
214
Direction
S
STREET_NAME
KELLY
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04906026
CURRENT_STATUS
01
SITE_LOCATION
214 S KELLY ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\222IAError\IAError\K\KELLY\214\PR0517911\COMPLIANCE 2000 - 2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
523
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
57_ 66265 . 195 (a) Failed to conduct daily inspection of tanks for <br /> following: discharge control equipment, corrosion, releases , <br /> monitoring and leak detection data, construction materials and <br /> secondary containment areas, and level of waste in uncovered tanks. <br /> (GOR) <br /> 58_ 66265 . 195 (b) Failed to inspect cathodic protection systems (if <br /> present) and sources of impressed current as appropriate. (GOR) <br /> 59_ 66265 . 196 Failed to remove from service immediately a tank system or <br /> secondary containment system that had leaked or spilled. (GOR) <br /> 60_ 66265 . 197 During closure of tank system, failed to remove or <br /> decontaminate all waste residues, contaminated tank system, soils, and <br /> manage them as HW. (GOR) <br /> 61_ 66265 . 198 (x) Stored or treated in tanks ignitable or reactive waste so <br /> as to cause the waste to ignite or react. (GOR) <br /> 62_ 66265. 198 (b) Failed to comply with buffer zone requirements for tanks <br /> containing ignitable or reactive wastes per NFPA "Flammable and <br /> Combustible Liquids Code. (GOR) <br /> 63_ 66265 . 199 (a) Stored incompatible wastes in same tank without complying <br /> with 66251. 17 (b) . (GOR) <br /> 64_ 66265 . 199 (b) Placed HW in non-decontaminated tanks that previously <br /> held an incompatible waste or material without complying with <br /> 66251. 17 (b) . (GOR) <br /> onitable , Reactive , or incompatible Wastes <br /> NOTE: The following requirement applies to generators per <br /> 66265 . 177 (a) for containers and 66265 . 199 (a) & (b) for tanks . <br /> 65_ 66265 . 17 (b) Failed to conduct transfer, storage, treatment, or <br /> disposal of ignitable or reactive wastes / mixture or commingling of <br /> incompatible wastes/materials to prevent: <br /> — (1) Generation of extreme heat or pressure, fire or explosion, <br /> or violent reaction. <br /> (2) Production of uncontrolled toxic mists, fumes, dusts or <br /> gases to threaten human health or environment. <br /> (3) Production of uncontrolled flammable fumes or gases to pose <br /> risk of fire or ex-plosions. <br /> (4) Damage to structural integrity of HW containment devices . <br /> (5) Threat to human health or the environment. (GOR) <br /> 7 <br />