My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOOMIS
>
2660
>
2200 - Hazardous Waste Program
>
PR0507075
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2019 11:37:57 AM
Creation date
11/6/2018 8:40:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO_PRE 2019
FileName_PostFix
PRE 2019
RECORD_ID
PR0507075
PE
2228
FACILITY_ID
FA0007705
FACILITY_NAME
J B HUNT TRANSPORT INC
STREET_NUMBER
2660
STREET_NAME
LOOMIS
STREET_TYPE
RD
City
STOCKTON
Zip
95204
APN
17910001
CURRENT_STATUS
01
SITE_LOCATION
2660 LOOMIS RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS3\222IAError\IAError\L\LOOMIS\2660\PR0507075\COMPLIANCE INFO 2001 - 2016.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
359
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D.Results of Testing/Servicing <br /> Software Version Installed: 131.01 <br /> Complete the following checklist: <br /> ❑X Yes ❑No* Is the audible alarm operational? <br /> ❑X Yes ❑No* Is the visual alarm operational? <br /> X❑ Yes ❑No* Were all sensors visually inspected, functionally tested,and con i inned operational'? <br /> ® Yes ❑No* Were all sensors installed at lowest point of secondary containmcnt and positioned so that oilier equipment <br /> will not interferewith their <br /> Proper o ration? <br /> 0 Yes ❑No* If alarms are relayed to a remote monitoring station, is all communications equipment(e.g.modem) <br /> ❑N/A operational? <br /> X❑ Yes ❑No* For pressurized piping systems. does the turbine automatically shut down if the piping secondary <br /> N/A containment monitoring system detects a leak, fails to operate,or is electrically disconnected?If es:which <br /> sensors initiate positive shut-down?(Check all that apply) <br /> ❑Sump/Trench Sensors; ❑X Dispenser Containment Sensors. Did you confirm positive shut-down <br /> due to leaks and sensor failure/disconnection? <br /> Yes; ❑No. <br /> ❑ Yes ❑No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e. no <br /> ©N/A mechanical overt-ill prevention valve is installed),is the overfill warning alarm visible and audible at the <br /> tank fill point(s)and operating properly?If so,at what percent of tank capacity does the alarm trigger? <br /> ❑Yes* ® No Was any monitor;n,equipment replaced?If yes,identify specific sensors,probes,or other eyuipmcnt <br /> relaced and list the nrutufacturer nameand model for all replacement parts in Section E,below. <br /> "Yes* © No Was liquid found inside any secondary containment systems designed as dry systems?(Check all that <br /> apphv) ❑Product; ❑Water.I t'y es,describe causes in Section E,below. <br /> ❑X Yes ❑No* Was monitoring system set-up reg icwed to ensue:proper settings?Attach set up reports,if applicable <br /> © Yes ❑No*��Is all monitoring cqutpment operational per manufacturer's specifications? <br /> `In Section l below,describe how and%then these deficiencies%sere oraill be corrected. <br /> E. Comments: <br /> Other sensors from page one: <br /> L2 Pump Box 794390-420:Certified. <br /> L3 Transition Box 794380-208:Certified. EC <br /> I Zl�1tJ <br /> The drop tube is equipped with a mechanical overfill prevention valve. <br /> EENVIRONMENT f <br />
The URL can be used to link to this page
Your browser does not support the video tag.