COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
1815
>
2200 - Hazardous Waste Program
>
PR0220065
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2019 10:44:50 AM
Creation date
11/6/2018 8:40:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0220065
PE
2220
FACILITY_ID
FA0001889
FACILITY_NAME
ALCO METALS
STREET_NUMBER
1815
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
1633006
CURRENT_STATUS
01
SITE_LOCATION
1815 NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS3\222IAError\IAError\N\NAVY\1815\PR0220065\COMPLIANCE INFO 1989 - 2001.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
464
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Yes No Comment <br /> 90 Dav Ac . Trm11ation in Tanks (cont <br /> (Section 66262.34) <br /> Is the secondary containment system (if required, <br /> see table on page 14) , at a minimum. <br /> [66265.193(c)-) <br /> (1) Constructed of or lined with materials <br /> that are compatible with the waste(s) to be <br /> placed in the tank system, and have sufficient <br /> strength to prevent failure? <br /> (2) Placed on a foundation or base capable of <br /> providing support to the secondary containment <br /> system and resistance to pressure gradients? <br /> (3) Provided with a lead detection system <br /> designed and operated to detect the failure of <br /> either the primary and secondary containment, <br /> or any release within 24 hrs or ASAP? <br /> (4) Sloped, or designed or operated, or to — <br /> remove liquids? <br /> If there is a release, has material and <br /> accumulated precipitation removed within <br /> 24 hrs or ASAP?, and.. [66265.193(c) (4)-] <br /> (A) If a HW, managed according to all — <br /> applicable requirements of Chs. 2 - 15? <br /> (B) If discharged through point source to US — <br /> waters, are sections 301, 304, and 402 of the <br /> Federal Clean Water Act (CWA) complied with? <br /> (C) If discharged to a Poiw, is section <br /> 307 of the CWA complied with? <br /> (D) If released to the environment, have —' <br /> reporting requirements of 40 CFR Part 302 <br /> complied with? <br /> Dc)eS secondary containment include one or more <br /> of the following: [66265.193(d)-] <br /> (1) An external liner?, or <br /> (2) A vault?, or <br /> (3) A double-walled tank?, or — <br /> (4) An equivalent device approved by the <br /> Department? <br /> Revised 7/15/91 Page 13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.