My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
1333
>
2200 - Hazardous Waste Program
>
PR0522742
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2019 11:12:06 AM
Creation date
11/6/2018 8:41:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0522742
PE
2227
FACILITY_ID
FA0005630
FACILITY_NAME
CENTRAL VALLEY WASTE SERVICES
STREET_NUMBER
1333
Direction
E
STREET_NAME
TURNER
STREET_TYPE
RD
City
LODI
Zip
95241
APN
04908045
CURRENT_STATUS
01
SITE_LOCATION
1333 E TURNER RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS3\222IAError\IAError\T\TURNER\1333\PR0522742\COMPLIANCE INFO 1994 - 2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
588
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br />LUBE CUBE® Specifications Page 2 of 2 <br />2.0 PRIMARY STORAGE TANK (SINGLE WALL TANKS) <br />2.1 The standard primary storage tank shall be rectangular in design. The tank will be constructed of UL <br />142 specified steel thickness, with continuous welds. <br />2.2 The primary storage tank shall be constructed of ASTM A-569 or A-36 carbon steel, as required for <br />compatibility of product being stored. <br />2.3 The primary tank shall be pressure tested in the factory to UL 142 specifications (3 PSI). <br />2.4 The tank shall be fitted with: a 2" fill port, a 2" normal vent, either a 4", 6" 6" or 10" emergency vent <br />port, a 2" liquid gauging port, two (2) 2" spare ports, and an 18" manway (for tanks with capacities of <br />5,000 gallons and larger) <br />3.0 SECONDARY CONTAINMENT TANK (DOUBLE WALL TANKS) <br />3.1 The secondary containment tank shall be rectangular in design and constructed of UL 142 specified <br />steel thickness, with continuous welds. <br />3.2 The secondary containment tank shall be listed by Underwriters Laboratories as secondary <br />containment under UL 142 standard. <br />3.3 The secondary containment tank shall provide a minimum of 110% secondary containment. <br />3.4 The secondary containment tank shall be equipped with a 2 inch monitoring port and a 4", 6", 8", or <br />10" emergency vent port as required by Underwriters Laboratories, Inc. <br />3.5 The secondary containment tank shall be pressure tested'in the factory to UL 142 specification (3 <br />PSI). <br />4.0 COATINGS: <br />4.1 The exterior surface of the secondary tank shall be cleansed of foreign material and coated with a <br />corrosion resistant industrial paint (3 to 5 mils dry film thickness). <br />4.2 The standard color shall be desert sand. <br />4.3 An optional coating (FIBERVAULT) can be applied to the exterior surface of the secondary tank to <br />provide resistance to corrosive environments such as salt water spray. <br />4.3.1 The total dry thickness shall be a minimum of 1/8 inch. <br />4.3.2 All threaded openings and Flanges shall be protected during the coating process. <br />4.3.3 The coating shall be applied only when the work area and the secondary steel tank are <br />between the temperatures of 32 and 103 degrees F. <br />4.3.4 The standard color shall be desert sand. <br />4.3.5 The coating shall provide a 10 year warranty. <br />htip: //www, containmentsolutions.com/productsllubecube/3 5 02C%2OLubecube-specO3-09.h... 6/2/2009 <br />
The URL can be used to link to this page
Your browser does not support the video tag.