Laserfiche WebLink
dIFIED PROGRAM CONSOLIDATED FORM TANK: TA0438304 <br /> ' J PR#: PR0234383 <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 FAC#; m670 <br /> f J (two pages perer tank)nk) <br /> Page 4 of <br /> TYPE OF ACTION ❑ I NEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑6 TEMPORARY SITE CLOSURE <br /> (O"`("nty it..*) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> (Speeifyram-f«laal uedY) (Spmfytusat fa lodue uNK REMOVED 430 <br /> ❑BTAN <br /> ❑ 3RENEWAL PERMIT _ <br /> BUSINESS NAME(Stsosw FA ILITYNAMEor DBA-Doing Bwiovs As) FACILITY ID: PR#: 1 <br /> LINDEN ASSOCIATED GROWERS FA0003670 PR0234383 <br /> LOC6,TIONWITH NSITEOptioatto 14175 E HWY 26,LINDEN 431 <br /> PHONE <br /> L TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agemy.) <br /> TANK ID# Tank#: 4 43i TANK MANUFACTURER 433 CONIPARTMENTALIZED TAMC ®Yes ❑No 434 <br /> TA0438304 vYes•cpnplaaue ggeax e«b`°«p'"m°'c <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 3/1/1992 12:00:00AM 10,500 <br /> ADDITIONAL DESCRIPTION(F«lod uaeady) 438 <br /> 3/13/00 CUING PE FR 2315 TO 2360 PER TISH.LBR <br /> H.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 4m <br /> ® I.MOTOR VEHICLE FUEL ® la.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> (lfnukerlwmplere Pnrolcam Type) ❑ Ib.PREMIUM UNLEADED ❑ 3.DIESEL ❑6.AVIATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM ❑ Ic MIDGRADE UNLEADED ❑4.GASOHOL [199.OTHER <br /> ❑ 3.CHEMICAL PRODUCT COMMON NAME(from HevNan Mm ,t I W n page) qql CAS#(6omnawdms Materials Io,-"page) 442 <br /> ❑4.HAZARDOUS WASTE <br /> (Wa1u6m u.odoa/ <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPEOFTANK ❑ 1.SINGLE WALL ❑ 3.SINGLE WALL WITH E:1 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Cle4kooeitemonly) EXTERIOR MEMBRANE LINER ❑ 95.UNKNOWN <br /> ®2.DOUBLE WALL ❑ 4.SINGLE WALL IN VAULT ❑99.OTHER <br /> TANK MATERIAL-primary tmk ❑ I.BARE STEEL ❑ FIBERGLASS/PLASTIC ❑5.CONCRETE El 95.UNKNOWN 444 <br /> (Chert ane iron ady) ❑2.STAINLESS STEEL ® STEEL CLAD W/FIBERGLASS ❑8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99.OTHER <br /> TANK MATERIAL-secondary tank ❑ I.BARE STEEL ❑3.FIBERGLASS/PLASTIC [15.CONCRETE ❑95.UNKNOWN 445 <br /> (Cnmk«mnemady) ❑ 2.STAINLESS STEEL ❑4.STEEL CLAD W/FIBERGLASS ❑ a.FRP COMP 1RLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑99.OTHER <br /> [7 5.CONCRETE <br /> TANK INTERIOR LINING E:] I.RUBBER LINED El3.EPDXY LINING ❑ 5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING <br /> (Ch«kamitemooly) ❑ 2ALKYD LINING El4PHENOLIC LINING ®6UNLINED ❑99.OTHER F«lod <br /> ( ucadY) <br /> OTHER CORROSION ❑ I MANUFACTURING CATHODIC M 3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> ❑4IMPRESSED CURRENT ❑ 99 OTHER <br /> (Chale wait®m1Y) ❑25ACRIFICIAL ANODE (F«lad uewdy) <br /> SPILL AND OVERFILL YEAR INSTALLE450 TYPE(local ue wty) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 451 <br /> (CMcka,,osapply) ❑ I SPILL CONTAINMENT ❑ IALARM ❑ 3 FILL TUBE SHUT OFF VALE <br /> ❑ 2 DROP TUBE ❑ 2 BALI, ❑ 4 EXEMPT <br /> ❑ 3STRIKER PLATE FLOAT <br /> IV.TANK LEAK DETECTION(Amaiprioaortaemannarivg t<.lwl uesamaimdrotlslad aaciayJ <br /> IF SINGLE WALL TANK(Ciwrk dl dw apply) 453 E DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ I VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) (Cn otu,itm oety) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ❑ I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER M 2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING F1 99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YRIMO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> ❑Yes ❑ No <br /> UPCF(12/99 revised) <br />