Laserfiche WebLink
ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />L12:PUMP 7-8 <br />LEAK TEST METHOD <br />TRI-STATE (SINGLE FLOAT) <br />TANK TEST NOTIFY: OFF <br />ALL TANK <br />: DISPENSER PAN <br />TEST ON DATE <br />TNK TST SIPHON BREAKOFF <br />JAN 1,1996 <br />: DISABLED <br />DELIVERY DELAY I MIN <br />START TIME <br />TEST RATE0.20HR <br />L13:PUMP 9-10 <br />DURATION HOURS <br />TRI-STATE (SINGLE FLOAT) <br />STOP:DISABLED <br />CATEGORY : DISPENSER PAN <br />TST EARLY <br />LEAK TEST REPORT <br />NFORMAT <br />L14:PUMP 11-12 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />T 3:UNLEADED 87 <br />OUTPUT RELAY SETUP <br />PRODUCT CODE 3 <br />THERMAL COEFF :.000700 <br />k 1:DSL STP <br />TANK DIAMETER : 127.50 <br />TYPE: <br />TANK PROFILE 4 PTS <br />FULL VOL : 15051 <br />STANDARD <br />95.6 INCH VOL : 12085 <br />LIQUID SENSOR SETUP - <br />- <br />NORMALLY CLOSED <br />63.8 INCH VOL : 7550 <br />- - - - - - - - - - <br />31.9 INCH VOL : 2960 <br />L IDSL ANNULAR <br />IN -TANK ALARMS <br />TRI-STATE (SINGLE FLOAT) <br />T 1:HIGH WATER ALARM <br />FLOAT SIZE: 4.0 IIV. <br />CATEGORY : ANNULAR SPACE <br />T 1:LOW PRODUCT ALARM <br />WATER WARNING 1.0 <br />LIQUID SENSOR ALMS <br />L 2:FUEL ALARM <br />HIGH WATER LIMIT: 2.0 <br />2:DSL STP SUMP <br />L12:FUEL ALARM <br />MAX OR LABEL VOL: 15051 <br />L <br />TRI-STATE (SINGLE FLOAT) <br />SUMP <br />L14:FUEL ALARM <br />L 2:SENSOR OUT ALARM <br />OVERFILL LIMIT 90% <br />CATEGORY : STP <br />L12:SENSOR OUT ALARM <br />13546 <br />95% <br />L14:SENSOR OUT ALARM <br />HIGH PRODUCT <br />14296 <br />L 3:91 FILL SUMP <br />L 2:SHORT ALARM <br />DELIVERY LIMIT 10% <br />TRI-STATE (SINGLE FLOAT) <br />PIPING SUMP <br />L12:SHORT ALARM <br />L14:SHORT ALARM <br />1505 <br />CATEGORY : <br />LOW PRODUCT 450 <br />LEAK ALARM LIMIT: 99 <br />L 4:91 STP SUMP <br />R 2:91 STP <br />TYPE: <br />SUDDEN LOSS LIMIT: 99 <br />TRI-STATE (SINGLE FLOAT) <br />STP SUMP <br />STANDARD <br />NORMALLY CLOSED <br />TANK TILT 0.00 <br />CATEGORY : <br />MANIFOLDED TANKS <br />TO: NONE <br />L 5:87 ANNULAR <br />NK A LARMS <br />IIV -TANK A <br />TRI-STATE (SINGLE FLOAT) <br />T 2:WATER ALARM <br />CATEGORY : ANNULAR S PACE <br />T 2:LOW PRODUCT ALARM <br />LEAK MIN PERIODIC: 00 <br />LIQUID SENSOR ALMS <br />L 4:FUEL ALARM <br />LEAK MIN ANNUAL 00 <br />L 6:87 FILL SUMP <br />FLOAT) <br />L 9:FUEL ALARM <br />L10:FUEL ALARM <br />TRI-STATE (SINGLE <br />CATEGORY : PIPING SUMP <br />L11:FUEL ALARM <br />L12:FUEL ALARM <br />PERIODIC TEST TYPE <br />SUMP <br />L13:FUEL ALARM <br />L14:FUEL ALARM <br />STANDARD <br />L 7:67 STP <br />TRI-STATE (SINGLE FLOAT) <br />L 4:SENSOR OUT ALARM <br />ANNUAL TEST FAIL <br />CATEGORY : STP SUMP <br />L 9:SENSOR OUT ALARM <br />L10:SENSOR OUT ALARM <br />ALARM DISABLED <br />Lll:SENSOR OUT ALARM <br />PERIODIC TEST FAIL <br />L 9:PUMP 1-2 <br />FLOAT) <br />L12:SENSOR OUT ALARM <br />L13:SENSOR OUT ALARM <br />ALARM DISABLED <br />TRI-STATE (SINGLE <br />CATEGORY : DISPENSER PAN <br />L14:SENSOR OUT ALARM <br />GROSS TEST FAIL <br />L 4:SHORT ALARM <br />L 9:SHORT ALARM <br />ALARM DISABLED <br />LIO:SHORT ALARM <br />ANN TEST AVERAGING: OFF <br />L10:PUMP 3-4 <br />FLOAT) <br />L11:SHORT ALARM <br />L12:SHORT ALARM <br />PER TEST AVERAGING: OFF <br />TRI-STATE (SINGLE <br />CATEGORY : DISPENSER PAN <br />L13:SHORT ALARM <br />TANK TEST NOTIFY: OFF <br />L14:BHORT ALARM <br />TNK TST SIPHON BREAKOFF <br />R 3:87 STP <br />TYPE: <br />DELIVERY DELAY 1 MIN <br />L11:PUMP 5-6 <br />TRI-STATE (SINGLE FLOAT) <br />STANDARD <br />CATEGORY : DISPENSER PAN <br />NORMALLY CLOSED <br />