My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_1985-1990
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
33 (STATE ROUTE 33)
>
35100
>
2300 - Underground Storage Tank Program
>
PR0504582
>
BILLING_1985-1990
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:59:14 AM
Creation date
11/6/2018 9:37:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1985-1990
RECORD_ID
PR0504582
PE
2333
FACILITY_ID
FA0009340
FACILITY_NAME
Nutrien Ag Solutions - Vernalis
STREET_NUMBER
35100
Direction
S
STREET_NAME
STATE ROUTE 33
City
VERNALIS
Zip
95385
APN
25518008
CURRENT_STATUS
02
SITE_LOCATION
35100 S HWY 33
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\HWY 33\35100\PR0504582\BILLING 1985-1990.PDF
QuestysFileName
BILLING 1985-1990
QuestysRecordDate
8/21/2017 6:35:46 PM
QuestysRecordID
3597006
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORN* WATER RESOURCES CONTRSBOARD QO <br /> FORMIBI: UNDERGROUND STORAGE TANK PROGRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION G�COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> MARK ONLY ❑ I NEW PERMIT ❑ 3 RENEWAL PERMIT CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOS NK <br /> ONE ITEM ❑2INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE <br /> //,^, ❑B TANK REMOVED Q <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: Q� 3 3 ,� l,/d. FARM TANK-YES❑ NO �• <br /> B •� <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS•IF UNKNOWN-80 SPECIFY a <br /> A. OWNERS TANK ID 6 IB. MANUFACTURED BY: (/ cn <br /> C. YEAR INSTALLED ID. TANK CAPACITY IN GALLONS: <br /> G <br /> II. TANK CONTENTS IF(A1),IS MARKED,COMPLETE ITEM C.IF(A1),IS NOT MARKED,COMPLETE ITEM D. CA <br /> A. MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED LEADED ❑ 3 DIESEL <br /> ❑3 CHEMICAL PRODUCT ❑ 4 OIL 1 PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ B9 EMPTY ❑95 UNKNOWN ❑2 WASTE ❑ 7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.9 C.A.S.X: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A.B,C.8 D <br /> A.TYPE OF ❑ 1DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑ 4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑ I STEEUIRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B TANK MATERIAL ❑5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM E]8 190%METHANOL COMPATIBLE FRP <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> C.INTERIOR ❑ I RUBBERUNED ❑2 ALKYD UNING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING ❑ 6 UNLINED ❑95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH IID%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> D.CORROSION ❑ I POLYETHLENEWRAP ❑2 TM OR ASPHALT ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IFAPPLICABLE <br /> A. SYSTEM TYPE A U I SUCTION A U 2 PRESSURE A U 3 CHI A U 91 NONE A U 95 UNKNOWN A U 99 O1 HER <br /> 0. CONSTRUCTION A U I SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINCG TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U I STEEL/NON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U B CONCRETE A U 7 STEELCLADW/FHP A U B 199%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P 6 1 VISUAL CHECK P 8 2 INVENTORY RECONCILIAI ION P 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONO OH P 8 5 GROUND WAl ER MONITORING WELLS <br /> P S..6 PRECISION TESTING P 6 7 PRESSURE TESTING P S 91 NONE P 8 95 UNKNOWN P 8 99 OTHER <br /> VI.1 II'N----FORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> L ESTI MAI ED DAT E LAST USI 0(MO/YfR T 2 ESTIMAI ED OUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBS I ANCE REMAINING IN INUIT MATERIAL? ❑YES ❑ NO <br /> GALLONS <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT. <br /> APPLIGANI'9 NAME(PRIM?EU 8 SIGNAL UHL) DAI E <br /> I <br /> LOCAL AGENCY USE ONLY <br /> COUNTY M JURISDICTION 8 AGENCY 8 FACILITY ID 8 TANK ID B <br /> 3 � = �] Lod I I I1� � I i o v <br /> CURRENT LOCAL AGENCYF LITY IDM APPROVED BY NAPE PHONE/WITH AREA CODE <br /> IBES-fp" <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK 1 PERMIT AMOUNT SURCHARGE AMT. FEE CODERECEIPT 1 BY: /' / <br /> Am 1 <br /> I GBM B 15-29-891 THIS FORM MUST BE ACCOMPANIT BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORMA' HAS BEEN FILED// <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.