My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL 1989
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TAM O SHANTER
>
6215
>
2300 - Underground Storage Tank Program
>
PR0500980
>
REMOVAL 1989
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/22/2019 3:19:28 PM
Creation date
11/6/2018 9:45:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL
FileName_PostFix
1989
RECORD_ID
PR0500980
PE
2381
FACILITY_ID
FA0004953
FACILITY_NAME
NORMAC INC
STREET_NUMBER
6215
STREET_NAME
TAM O SHANTER
STREET_TYPE
DR
City
STOCKTON
Zip
95209
APN
09405011
CURRENT_STATUS
02
SITE_LOCATION
6215 TAM O SHANTER DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\T\TAM O'SHANTER\6215\PR0500980\REMOVAL 1989 .PDF
QuestysFileName
REMOVAL 1989
QuestysRecordDate
10/19/2017 7:20:23 PM
QuestysRecordID
3691237
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> SAN .7OAQUIN LOCAL HEALTH DISTRICT <br /> SAMPLING PROTOCAL FOR ROUTINE TANK REMOVALS <br /> The following represents minimum sampling criterion required for closure compliance. Soil <br /> samples collected shall be representative of native soils beneath the tank's <br /> invert [tank's bottom] at a collection depth not be exceed 2 - 4 feet. If contamination <br /> isdoctoS <br /> umendduring closure, an Unauthirized Release notification must be filled out and <br /> subm <br /> CCR- <br /> WATER NOT PRESENT IN THE TANK PIT <br /> — _ <br /> TANK SIZE MINIMUM NUMBER OF LOCATION OF SOIL SAMPLES <br /> SOIL SAMPLES <br /> Less than1000gallons ONE per tank Fill or pump end of tank <br /> 1000 - 10,000 gallons TWO per tank One at each end of tank <br /> 10,001 gallons and up THREE OR MORE Ends and Middle or <br /> per tankenerally spaced along <br /> ?he length of the tank <br /> Piping ONE EVERY 20 LINEAL FEET <br /> WATER IS PRESENT IN TANK PIT <br /> .. --- <br /> ER <br /> TANK SIZE MINIMUM NO OF LOCATION OF SOIL MINIMUM NUMB <br /> SOIL SAMPLES SAMPLES OF WATER SAMPLES <br /> 10,000 GALLONS From wall next to <br /> OR LESS tank ends at soil/ ONE <br /> (Single Tank) TWO groundwater. <br /> interface <br /> GREATER THAN From wall next to ONE <br /> 10,000 GALLONS tank ends at soil/ <br /> OR groundwater <br /> TANK CLUSTER FOUR interface <br /> OTHER S PEC I AL C(DNE)I T I ON S <br /> SLAB PRESENT IN TANK PIT <br /> Soil samples shall be obtained beneath the slab within native soils. Penetration through <br /> the obstruction will be required in order to collect the samples. [Physical removal of the <br /> obstruction will then allow sampling according to the above conditions. ] <br /> _....._........... <br /> _..._..... -—-- ._..._.-..._.. <br /> TANK SIZE MINIMUM NUMBER OF LOCATION OF SOIL SAMPLES <br /> SOIL SAMPLES <br /> Less than 1000 gallons THREE per tank Center and ends or sides <br /> 1000 - 10,000 gallons FIVE per tank Center and ends or sides <br /> 10,001 gallons and up FIVE OR MORE per Ends and <br /> yyMiddle and <br /> tank the lengthsoctheatank <br /> EH 23 047 12/88 <br /> REVISED 1/89 <br />