Laserfiche WebLink
OPERATING IT AI'I'LICATION-TANKINFORM N(OneformperUST) <br /> KERN COUNTY ENVIRONMENTAL HEAL VICL:S IFIED PROGRAM CONSOLIDATED FORM <br /> DEPARTMENT UNDERGROUND STORAGE TANK <br /> 2700 M STREET,SUITE 300 <br /> BAKERSFIELD,CA 93301 <br /> (661)862-8700 Fax(661)862-8701 (one page per tank) Page 1 of 4 <br /> TYPE OF ACTION (Check one item only. For an UST permanent closure or removal,complete only this section and Sections I,II,IB,IN,and IX below) 430 <br /> ® 1.NEW PERMIT ❑ 3.RENEWAL PERMIT ❑ 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.OST PERMANENT CLOSURE ON SITE ❑ 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 43011 DATE EXISTING UST DISCOVERED: 43% <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) I <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3 <br /> Love's Travel Stop#538 <br /> BUSINESS SITE ADDRESS [in I CITY 109 <br /> 15250 North Thornton Road Lodi <br /> D.TANK DESCRIPTION <br /> TANK ID# 1 432 TANK MANUFACTURER 433 TANK CONFIGURATION: THIS TANK IS 434 <br /> Xerxes ® LA STAND-ALONE TANK <br /> ❑ <br /> 2.ONE IN A COMPARTMENTED UNIT. <br /> Inc ane ia,,fish wmpaitiment in the unn. <br /> DATE UST SYSTEM INSTALLED 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS IN TBE UNIT 437 <br /> 92013 30000 1 <br /> III.TANK USE AND CONTENTS <br /> TANK USE W Ia.MOTOR VEHICLE FUELING ❑ Ib.MARINA FUELING ❑ Ic.AVIATION FUELING 439 <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Io W.Uaed On ❑ 5.EMERGENCY GENERATOR FUEL INK§25281.5(.)] <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 439a <br /> CONTENTS PETROLEUM: ® la REGULAR UNLEADED ❑ Ic.MIDGRADE UNLEADED ❑ Ib.PREMIUM UNLEADED 490 <br /> ❑ 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ S.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM (Specify): 44011 <br /> NON-PETROLEUM:❑ 7.USED OIL ❑ 10.ETHANOL <br /> ❑ <br /> 11.OTHER NON-PETROLEUMS if : 4406 <br /> IV. TANK CONSTRUCTION <br /> TYPE.OF TANK ❑ 1.SINGLE WALL ® 2.DOUBLE WALL ❑ 95.UNKNOWN 443 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ® 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444 <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.MUM Spmify): 444. <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ®3.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑99.OTHER(Specify) 44511 <br /> OVERFILL PREVENTION ® 1.AUDIBLE&VISUAL ALARMS ❑ 2.BALL FLOAT ® 3.FILL TUBE SHUT-OFF VALVE 452. <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑1.SINGLE-WALLED ®2.DOUBLE-WALLED ❑99.OTHER 460 <br /> SYSTEM TYPE 0 L PRESSURE ❑ 2.GRAVITY ❑ 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION In CCR§2636(a)(3)l 458 <br /> PRIMARY CONTAINMENT ❑ L STEEL ® 4.FIBERGLASS ❑ S.FLEXIBLE ❑ 10.RIGIDPLASTTC 464 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTYB3R(Spwify): 464a <br /> SECONDARY CONTAINMENT ❑ L STEEL ® 4.FIBERGLASS ❑ S.FLEXIBLE ❑ 10.RIGIDPLASTIC 4646 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464. <br /> PIPING/TURBINE CONTAINMENT SUMP TYPE ❑ 1.SINGLE WALL ® 2.DOUBLE WALL ❑ 90.NONE 4644 <br /> VL VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT ❑ 1.STEEL W 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464e <br /> 469e1 <br /> VENT SECONDARY CONTAINMENT ❑ I STEEL ® 4.FIBERGLASS ❑ HL RIGIDPLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464f <br /> 464Fl <br /> VR PRIMARY CONTAINMENT ❑ I.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 4646 <br /> 464 1 <br /> VR SECONDARY CONTAINMENT ❑ I.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464n <br /> ab4m <br /> VENT PIPING TRANSITION SUMPTYPE ❑ 1.SINGLE WALL 181 2.DOUBLE WALL ❑ 90.NONE 4691 <br /> RISER PRIMARY CONTAINMENT ® 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Spent') 469i <br /> 4641 <br /> LRAPPLICANTSIGNATURE <br /> ONDARY CONTAINMENT ❑ 1.STEEL 4.FIBERGLASS ❑ 10.RIGID PLASTIC ® 90.NONE ❑ 99.OTHER(Specify) 464k <br /> 464k1 <br /> ONENTS INSTALLED ® 1.SPILL BUCKET ® 3.STRIKER PLATEIBOTTOM PROTECTOR ® 4.CONTAINMENT SUMP 451. <br /> VII.UNDER DISPENSER CONTAINMENT(UDC) <br /> TION TYPE ❑ 1.SINGLE WALL ® 2.DOUBLE WALL ❑ 3.NO DISPENSERS ❑ 90.NONE 4698 <br /> CTION MATERIAL ❑ 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 99.OTHER(Specify) 469bc <br /> VIII. CORROSION PROTECTION <br /> MPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT ® 6.(SOLA PION 448, <br /> IX. APPLICANT SIGNATURE <br /> CATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true,accurate, <br /> and in fullm liance with legal requirements.NT SIGNATURE DATE 7/29/2013 470. <br /> NT NAME(print) Kimberly MI 471. APPLICANT TITLE West Coast Environmental Manager 472. <br /> T-B-12 Rev.(1220111) <br />