My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1985-2002
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TOKAY
>
32
>
2300 - Underground Storage Tank Program
>
PR0231378
>
BILLING 1985-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2024 10:54:07 AM
Creation date
11/6/2018 10:11:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1985-2002
RECORD_ID
PR0231378
PE
2361
FACILITY_ID
FA0003901
FACILITY_NAME
PACIFIC COAST PRODUCERS (TOKAY)
STREET_NUMBER
32
Direction
E
STREET_NAME
TOKAY
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04703020
CURRENT_STATUS
02
SITE_LOCATION
32 E TOKAY ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\TOKAY\32\PR0231378\BILLING 1985-2002.PDF
QuestysFileName
BILLING 1985-2002
QuestysRecordDate
8/17/2017 10:29:17 PM
QuestysRecordID
2595268
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�aeea <br /> STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION FORM B <br /> I <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 7 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANEN CLOSED ONSITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REM ED Q Z <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: ..jojt:4 <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS– SPECIFY IF UNKNOWN <br /> A OWNER'S TANK I.D.# O B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAY/YEAR) D. TANK CAPACITY IN GALLONS: p� �O <br /> II.TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C, ❑ la REGUTAfl UNLEADED 3 DIESEL ❑ 6 AVIATION GAS <br /> A 1 PRODUCT ❑ 10 PREMIUM UNLEADED 6 GASAHOL ❑ 7 METHANOL <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY � ❑ 1c MIDGRADE UNLEADED ❑ 5 JETFUEL ❑ 8 M65 <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ 99 OTHER(DESCRIBE IN REM D.BELOW) <br /> D. IF(A1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B.AND C.AND ALL THAT APPLIES IN BOX D AND E <br /> 7 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> A. TYPE OF <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK �1 BARE STEEL E] 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL F-1 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED ❑ 2 ALKYD UNING ❑ 3 EPDXY UNING ❑ 4 PHENOLIC LINING <br /> w <br /> LINING OR ❑ 5 GLASS LINING ❑ 6 UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES— NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION ❑95 UNKNOWN 99 OTHER <br /> CATHODIC PROTECTION ❑ 91 NONE <br /> PROTECTION OVERFILL PREVENTION EQUIPMENT INSTALLED(NEAR) <br /> SPILL CONTAINMENT INSTALLED(YEAR) DISPENSER CONTAINMENT YES_ NO <br /> E.SPILL AND OVERFILL,11C. DROP TUBE YES_ NO STRIKER PLATE YES_ NO_ <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> 1 MECI ON01.UNE LEuc 2 LINE TKIMNESS 3 COSMIWS IMERSTAL Ej 4 ELE MONIC UNE ❑5 AInOMATIC NMP ❑ 99 OTHER <br /> D. LEAK DETECTION ❑ DEFECTOR ❑ TESTINo ❑ MCNTORING [EAN oETECToII SHUTDOWN <br /> V.TANK LEAK DETECTION <br /> ❑ 7 VISUAL CHECK ❑ 2 RECONCILIATIONMANUAL AORY E] 3 VAE MONITORING E:] 4 GAUGINGIC TANK E] 5 GROUND MONITORING TER F76 ANNUALTESTING <br /> 7 CONTINUOUS INTERSTITIAL ❑ 8 SIR ❑ 9 TANK GAUGING MANUAL ❑ 10 M STINGY TANK E] 95 UNKNOWN ❑ 99 OTHER <br /> MONITORING <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br /> 1.ESTIMATED DATE LAST USED(MO/DAV/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES ❑ NO❑ <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> DATE <br /> TANK OWNER'S NAME <br /> (PRINTED d 61GNANPE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TANK# <br /> STATE I.D.# 3 = FT-E= O ?�! <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLIC ON-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED.FO��11 C MUST BE COMPLETED FOR INSTALLATIO S THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT�ILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THFAIGROUND STORAGE TANK REGULATIONS <br /> FORM B (6-95) <br /> a <br />
The URL can be used to link to this page
Your browser does not support the video tag.