Laserfiche WebLink
SHEETINDEX <br /> Sheet No. Sheet Title m <br /> 1 SITE PLAN cli <br /> E01030600 FILL SUMP DETAILS = I <br /> J E01030600-A FILL/VAPOR RISER CALCULATIONS a, <br /> E01030600-8 FILL/VAPOR RISER STATIC ELECTRICITY PROTECTION TO <br /> E01031100 DISPENSER CONTAINMENT DETAILS <br /> ® E01031400 ELECTRONIC MONITORING DETAILS M\ <br /> E01031500 VEEDER ROOT SPECIFICATIONS <br /> E01031900 CONCRETE SLAB DETAILS r <br /> WORK,, <br /> — � - INSTALL NEW SPILL CONTAINMENT ON FILL AND VAPOR RISERS N <br /> EXISTING VENT RISERS, TYP. - INSTALL NEW DISPENSER CONTAINMENT SUMPS 0 <br /> - INSTALL NEW FILL DROP TUBES WITH OVERFILL VALVE 1 m <br /> ( O Q - INSTALL NEW 36" FIBRELITE MANHOLE LIDS <br /> ® /1 I l8/,',N - INSTALL NEW FIBREUTE SUMPS AT TANK FILLS 1 0 M <br /> 8 - INSTALL NEW SUMP SENSOR AT FILL SUMP <br /> - PATCH A.C. PAVING AND CONCRETE AS REQUIRED <br /> GENERAL NOTES w s <br /> o <br /> 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT APPLICABLE EDITIONS THE UNIFORM BUILDING CODE, �r 2 <br /> UNIFORM PLUMBING CODE, UNIFORM MECHANICAL CODE, UNIFORM FIRE CODE, NATIONAL <br /> Z f <br /> ELECTRIC CODE, CAL-OSHA � d. <br /> CONSTRUCTION SAFETY ORDERS, AND ALL OTHER APPLICABLE STATE, CITY AND COUNTY ORDINANCES. `jR .0 <br /> 9� I Ah \ Ism ° § 2. CONTRACTOR SHALL DETERMINE THE LOCATION AND DEPTH OF ALL BURIED PIPES AND UTILITIES, WHETHER SHOWN V - d <br /> OR NOT SHOWN ON THESE PIANS, PRIOR TO THE START OF CONSTRUCTION. NOTIFY UNDERGROUND SERVICE ALERT <br /> el i i 1-800-227-2600, AT LEAST TWO WORKING DAYS PRIOR TO THE START OF CONSTRUCTION. <br /> 3. CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS PRIOR THE START OF CONSTRUCTION. <br /> ( I. 1 81 <br /> 1- 4. SITE SPECIFIC ARCHITECTURAL AND CIVIL DRAWINGS SHALL TAKE PRECEDENCE FOR REFERENCING ALL DIMENSIONS, <br /> I I IELEVATIONS AND EQUIPMENT LOCATIONS. <br /> �� �� I O o 5. ALL DIMENSIONS AND CONDITIONS SHALL BE CHECKED AND VERIFIED IN THE FIELD BEFORE STARTING ANY WORK, <br /> Q I I I ANY DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE FOR HIS DECISION PRIOR <br /> ci; 170 ` .qL. I ( vx I PROCEEDING WITH THE WORK. <br /> ( 9 _ 6. CONTRACTOR SHALL COORDINATE AND OBTAIN ALL REQUIRED TESTS, INSPECTIONS AND SIGN-OFFS AS REQUIRED BY <br /> L <br /> MANUFACTURER'S SPECIFICATIONS AND LOCAL REGULATIONS PRIOR TO BEING PLACED INTO OPERATION. PROVIDE COPIES <br /> OF TEST RESULTS TO OWNER AND REGULATORY AUTHORITIES. <br /> PRESSURE VACUUM VENT 7. ALL TANK AND DISPENSER SUMPS SHALL BE HYDROSTATICALLY TESTED (LAKE TEST) WITH STANDING WATER TO INSURE <br /> ( REFER TO ENLARGED PARTIAL PLAN BELOW NTS THAT THE SUMPS ARE WATERTIGHT IN ACCORDANCE WITH OWNER'S AND REGULATORY AGENCY REQUIREMENTS. <br /> 8. ALL TANK AND PIPING SYSTEMS, LEAK DETECTORS AND MONITORING SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH <br /> STATE, COUNTY, CIN AND OTHER LOCAL CODES AND REGULATIONS. CONTRACTOR SHALL GIVE REGULATORY AUTHORITY <br /> servers ..uoan AND OWNER'S REPRESENTATIVE 48 HOURS ADVANCE NOTICE OF AND TESTING OR INSPECTIONS. <br /> 9. CONTRACTOR SHALL PROTECT ALL EXISTING FACILITIES, BOTH PUBLIC AND PRIVATE, WHICH ARE TO REMAIN UNLESS zo <br /> NOTED OTHERWISE. CONTRACTOR SHALL REPAIR OR REPLACE, TO THE OWNER'S SATISFACTION, ANY EXISTING FACILITIES <br /> WHICH ARE DAMAGED AS RESULT OF CONTRACTOR'S OPERATIONS. <br /> SITE PLAN ON RAMP - INTERSTATE 205 - N 10. ALL TRENCHES IN TRAFFIC AREAS, INCLUDING PEDESTRIAN TRAFFIC AREAS, SHALL BE COVERED WITH TRAFFIC RATED o <br /> PLATES WHEN WORK IS NOT IN PROGRESS, w <br /> SCALE: 1"= 20'-0" 11, ALL WORK AREAS SHALL BE ADEQUATELY BARRICADED THROUGHOUT THE CONSTRUCTION PERIOD. <br /> 12. EDGES OF EXISTING PAVEMENT, CONCRETE SLABS, CONCRETE CURBS AND SIDEWALKS SHALL BE NEATLY TRIMMED z <br /> PRIOR TO PATCHING. CONTRACTOR SHALL SAWCUT EXISTING PAVEMENT, SLABS, ETC IN NEAT STRAIGHT LINES. <br /> 13. CONTRACTOR SHALL REPLACE TANK RISERS AS REQUIRED, PER SHELL ENGINEERS DIRECTION. Zi <br /> — — — — — — — — — — — — — — 14. WHEN BONDING A NEW SUMP COLLAR TO EXISTING SINGLE WALL TANKS, A NITROGEN BLANKET SHALL BE USED <br /> 24'-0" PER TANK MANUFACTURERS SPECIFICATIONS. <br /> EXISTING/NEW TANK SLAB 15. CONTRACTOR SHALL REPLACE MISCELLANEOUS BOXES EQUIVALENT TO EXISTING. MONITORING WELLS NEED WATERTIGHT BOXES. <br /> 16. CONTRACTOR SHALL BE RESPONSIBLE FOR ADDITIONAL CAVE-IN AT TANK EXCAVATION, BEYOND WHAT IS INDICATED ON THE <br /> N N O SPECIFICATIONS. o <br /> r - <br /> _ -- NOTES <br /> PREMIUMDIESEL Z <br /> 12K \ / 12K \ O SAWCUT EXISTING TANK SLAB TO EXPOSE TANK TOP A7 FILL/VAPOR RISERS <br /> I © INSTALL NEW NON-DISCRIMINATING SUMP SENSOR, (TYP. OF 4) REFER TO <br /> SHEET OE01031400 FOR INSTALLATION DETAILS (SLM.) W <br /> p p Ifm <br /> INSTALL NEW 4"0 BLACK STEEL FILL RISER AND NEW 4"0 BLACK STEEL OFFSET VAPOR RISER, Q <br /> © <br /> (TYP.) REFER TO SHEET #EO1030600 FOR INSTALLATION DETAILS ck:� <br /> sTP I sTP I C 7 <br /> OD NOT USED CI_ <br /> ZD <br /> TLM <br /> TLM E INSTALL NEW FILL DROP TUBE WITH OVERFILL PROTECTION VALVE SET AT 95% OF TANK CAPACITY <br /> O 'I L K O FOR POSITIVE SHUT-OFF, REFER TO EQUIPMENT LIST ON THIS SHEET FOR MAKE AND MODEL NUMBER (TYP.)101 Z <br /> ALJ <br /> OF INSTALL NEW SPILL CONTAINMENT ON FILL AND VAPOR RISERS, REFER TO EQUIPMENT <br /> LIST ON THIS SHEET FOR MAKE AND MODEL NUMBERS (TYP.) Z <br /> © INSTALL NEW FIBREUTE EMS90 48"0 SUMP BONDED ONTO NEW 48"0 TANK COLLAR, 'Q <br /> (TYP. OF 4) REFER TO SHEET #EO1030600 FOR INSTALLATION DETAILS Z <br /> " REINFORCE CONCRETE SLAB AROUND MANHOLE W/ 3-#4 REBAR 8' 0 <br /> B C E F O IN LENGTH 9"O.C., PLACE REBAR 6" FROM SIDES OF BOX, MIN, 2" COVER U <br /> G H M m <br /> P p ' O REPLACE EXISTING TANK SLAB, AS INDICATED ON TANK SLAB PIAN, WITH NEW B" REINFORCED CONCRETE. W Q <br /> O I I REFER TO DRAWING E01031900 N (n > <br /> � INSTALL PRESSURE/VACUUM VENT VALVE ON TANK VENT RISERS (TYP. OF 4), INSTALL Z U J <br /> PERMANENT YELLOW OR GOLD LABEL WITH BLACK LETTERING STATING THE L.J = <br /> POSITIVE AND NEGATIVE PRESSURE SETTINGS SPECIFIED BELOW: a- <br /> J * °I POSITIVE PRESSURE SETTING: 3A 3 0.5 INCHES H2O N Q m <br /> LEGEND NEGATIVE PRESSURE SETTING: B4O t 2.0 INCHES H2O Z �. � <br /> z ' <br /> O INSTALL NEW 36"0 FIBRELITE MANHOLE LID (TYP. OF 16) Q CL <br /> N C N G z z EXISTING TO REMAIN J U Q <br /> ® - EXISTING TO BE REMOVED © INSTALL NEW 3/4"0 CONDUIT FROM THE NEAREST MONITORING J-BOX, TO NEW SUMP AT FILLS, (TYP. OF 4). J 0 U <br /> o O 1 NEW CONSTRUCTION H <br /> EXTENT OF CONSTRUCTION O INSTALL STATIC GROUNDING ON ALL TANK RISERS, REFER TO DRAWING E01030600-B W J <br /> I- wNa <br /> A O SAWCUT EXISTING ISLAND AS REQUIRED TO REMOVE EXISTING UNDER DISPENSER CONTAINMENT SUMPS /1 = M cr- <br /> V,J <br /> ORE-INSTALL EXISTING DISPENSERS ON EXISTING ISLANDS, WITH NEW UNDERDISPENSER CONTAINMENT <br /> SUMPS (TYP. OF 6). INSTALL BEI NON-DISCRIMINATING SUMP SENSOR. REFER TO SHEET #E0103i 100 FOR <br /> INSTALLATION DETAILS. DRAWN BY: JLR <br /> © EXISTREVIEWED BY: JLR <br /> DATE:SPANNER CABINET, (TYP. OF 6) DATE: <br /> M M EQUIPMENT LIST JOB NO: 12156.1 <br /> I _ <br /> N O N C I i. NO EQUIPMENT DESCRIPTION MANUFACTURER MODEL QUANTITY SUPBPLIED NOTES �EC 113 <br /> t!aa <br /> s P STP I (D UNDERGROUND STORAGE TANK EXISTING 000BLEWALI EXISTING TANK BURY <br /> 7 r - - - , DEPTH IS 4'-O"f <br /> ROTATABLE ADAPTER (FILL) OPW 61SALP-E'VR DIST. <br /> L - - 4" DUST CAP (FILL) OPW 634TT-EVR DIST. <br /> I ® SPILL CONTAINMENT BUCKET (FILL) OPW/POMECO 1-2100 SERIES DIST. <br /> p p I REGUK R ) PPLUSPRESSURE/VACUUM VENT VALVE HUSKY 4885 (2" THREADED) DIST. <br /> Z <br /> 4" DROP TUBE OPW 61SO-EVR (W/ OPD) DIST. <br /> a <br /> O7 ROTATABLE ADAPTER (VAPOR) OPW 61VSA-LVR DIST. SHEET <br /> JQ8 4" DUST CAP (VAPOR) OPW 1711T-EVR DIST. <br /> O9 SPILL CONTAINMENT BUCKET (VAPOR) OPW/POMECO 1-2100 SERIES DIST. <br /> ENLARGED PARTIAL PLAN 4" E MANHOLE LID FIBRELITE FL38 DIST. <br /> 11 4" EXTRACTOR FITTING OPW 233 DIST. VAPOR RISER <br /> SCALE: 1/8"= V-0" 12 48"0 SUMP W/ 42"0 TANK COLLAR FIBRELITE FMS90 DIST. <br /> 13 DISPENSER CONTAINMENT SUMP BEI FACTORY ASSEMBLED SHELL OF 8 SHEETS <br />