_ — ..— _ <br /> 100 OHMS MAXIMUM <br /> 2 POINT GROUND-EARTH -- .-.- <br /> UNDERGROUND RESISTANCE_ <br /> STORAGE TANK \ COMPOSITE ASSEMBLY - <br /> METAL ASSEMBLY TESTING : NOTES: <br /> \ CAUTION: AVOID CONNECTING ANY ELECTRICAL TEST ALL STAGE I FILL AND VAPOR RISER ADAPTERS SHALL BE <br /> BONDING /� GROUND \ r LEAD TO THE FILL OR VAPOR RISER IN A MANNER ELECTRICALLY GROUNDED TO PROMOTE THE <br /> JUMPER CONNECTOR INDEPENDENT THAT WOULD POTENTIALLY PRODUCE STATIC RELAXATION OF STATIC CHARGE, <br /> GROUND DISCHARGE OR SPARKS OF ANY KIND, <br /> HIGH RESISTANCE OR NON-CONDUCTIVE FLUID FLOWING <br /> 1 OOK OHMS THE FILL AND VAPOR RISERS SHALL BE TESTED <br /> SUMP MAX. AFTER INSTALLATION AND PERIODICALLY TO VERIFY THOUGH PIPING CAN GENERATE STATIC CHARGES <br /> CAPABLE OF IGNITING FUEL VAPORS, PROPER BONDING <br /> BONDING AND GROUNDING COMPETENCY. AND GROUNDING OF THE FILL AND VAPOR RISER <br /> I <br /> ASSEMBLIES ARE NECESSARY TO ASSURE SAFE FILLING <br /> THE MAXIMUM RESISTANCE FROM ANY FILL OR OPERATIONS. <br /> _ VAPOR ADAPTER TO THE BODY OF THE GROUND <br /> ROD SHALL NOT EXCEED 10 OHMS FOR A THE BONDING AND GROUNDING FOR STATIC ELECTRICITY <br /> METALLIC RISER PIPE, SPILL CONTAINMENT AND PROTECTION SHALL BE IN COMPLIANCE PER ALL <br /> ADAPTER ASSEMBLIES. <br /> j -- -- APPLICABLE FEDERAL, STATE AND LOCAL CODES <br /> INCLUDING NFPA 30, FLAMMABLE AND COMBUSTIBLE <br /> UNDERGROUND THE RESISTANCE THROUGH ANY COMPOSITE OR LIQUIDS CODE, NFPA 77, RECOMMENDED PRACTICE ON <br /> STORAGE TANK \ NONMETALLIC STAGE I CONTAINMENT FITTING SHALL STATIC ELECTRICITY, NFPA 70, NATIONAL ELECTRIC CODE, <br /> TESTING BURIED GROUND_ ROD SYSTEM (EXTG. SITES) BE MEASURED WITH A OHMMETER CAPABLE OF <br /> \ READING UP TO 10 MEGAOHMS. PER THE SHELL AND THE CALIFORNIA CODE OF REGULATIONS, <br /> STANDARD, THE SUM COLLECTIVE RESISTANCE OF SUBCHAPTER 15, PETROLEUM SAFETY ORDERS-REFINING, <br /> I GROUND THESE SEMI-CONDUCTIVE ELEMENTS SHALL NOT TRANSPORTATION AND HANDLING, ARTICLE 5, FIRE AND <br /> B CONNECTOR <br /> EXPLOSIONS. <br /> EXCEED 100,000 OHMS. FOR THESE SYSTEMS, <br /> JUMPER THE GROUND RESISTANCE TESTER MUST BE <br /> CONNECTED TO THE GROUND CONDUCTOR PER SECTION 6.THE R NEPA 77, THE MEASURED TOTAL <br /> 10 OHMS CONNECTION ON THE COMPOSITE CONTAINMENT M THE RESISTANCE GROUND PATH EARTH SHALL BE <br /> SUMP SYSTEM OR RISER PIPE. LESS THAN 1 EGAOHM WHICH IS CONSIDERED SIDERED <br /> / MAX. ADEQUATE FOR RELAXATION OF STATIC CHARGE, THE <br /> COMPOSITE ASSEMBLY --- TEST LEAD CONNECTED FOR INSTALLATIONS WITHOUT AN EXPOSED GROUND MAXIMUM ALLOWABLE GROUND PATH TO EARTH <br /> — TO GROUND ROD RESISTANCE FOR STATIC ELECTRICITY GROUNDING <br /> METAL ASSEMBLY ROD CONNECTION, TOTAL SYSTEM RESISTANCE APPLICATIONS FOR SHELL OIL PRODUCTS US STATION <br /> (NOT LUG OR WIRING) SHALL BE MEASURED WITH A GROUND RESISTANCE SITES SHALL NOT EXCEED 100,000 OHMS. <br /> ,( TESTER BY A QUALIFIED ELECTRICIAN FAMILIAR WITH <br /> GROUND TESTING. THE TWO POINT METHOD MAY PER SECTION 6.4.1.3 OF NFPA 77, THE RESISTANCE IN <br /> BE USED WITH THE SITE ELECTRICAL GROUNDING METALLIC BONDING AND OR GROUNDING SYSTEMS SHALL <br /> UNDERGROUND AS THE SECOND TEST POINT. BE LESS THAN 10 OHMS. RESISTANCE HIGHER THAN 10 <br /> STORAGE TANK \ 100K OHMS OHMS INDICATES INADEQUATE CONNECTIONS. <br /> THE NEC MAXIMUM GROUND PATH RESISTANCE FOR <br /> MAX. CURRENT CARRYING APPLICATIONS IS 25 OHMS. <br /> HOWEVER, GROUND ROD TO EARTH RESISTANCE UP A GROUNDING SYSTEM PER NEC CODE FOR CURRENT <br /> GROUND —_� . TO 100 OHMS SHALL BE ACCEPTABLE PER THE CARRYING CONDUCTORS SHALL BE CONSIDERED MORE <br /> BONDING CONNECTOR SHELL STANDARD FOR STATIC ELECTRICITY THAN ADEQUATE FOR A STATIC ELECTRICITY GROUNDING <br /> JUMPER `- .-- PROTECTION OF THE FILL AND VAPOR RISERS. SYSTEM. <br /> PER THE NFPA 30, SECTION 5-6,3.4 ALL PARTS OF THE FILL <br /> SUMP / _ PIPE ASSEMBLY, INCLUDING THE DROP TUBE, SHALT_ <br /> FORM A CONTINUOUS ELECTRICALLY CONDUCTIVE PATH. <br /> TESTINGEXPOSED GROUND ROD SYSTEM SIZING OFTHE GROUNDING AND BONDING WIRE <br /> BACKFILL w7STE_ CONDUCTORS FOR STATIC PROTECTION SYSTEMS IS <br /> TYPICALLY BASED ON MECHANICAL STRENGTH RATHER <br /> NATIVE SOIL THAN CURRENT CARRYING CAPACITY. HOWEVER, PER <br /> PLAN VIEW �__ 8"� O THE CALIFORNIA CODE OF REGULATIONS, THE MINIMUM <br /> GROUND ACCESS EXTREME CAUTION MUST BE OBSERVED WHILE USING ANY NON-INTRINSICALLY WIRE SIZE FOR BONDING AND GROUNDING SHALL BE <br /> ROD COVER ' SAFE DEVICE IN CLASSIFIED AREAS. SUMP MUST BE TESTED FOR VOLATILE ' COPPER AWG #8 <br /> ■ VAPORS PRIOR TO USE. ELECTRICAL CONNECT MUST BE MADE WITH JUMPER ■ A5/8"O BY 10' LONG COPPER CLAD STEEL GROUND ROD <br /> WIRE SO FINAL CONNECTION IS AWAY FROM CLASSIFIED AREAS, SHALL BE DRIVEN INTO NATIVE SOIL ONLY, PLACING THE <br /> GROUND ROD INTO TANK PIT PEA GRAVEL SHALL NOT BE <br /> PERMITTED UNDER ANY CONDITIONS. THE CONTRACTOR <br /> IS RESPONSIBLE FOR CLEARING ANY UNDERGROUND <br /> UTILITIES PRIOR TO INSTALLATION OF THE GROUND, <br /> O GROUND ROD CLAMP 8° H-20 O THE GROUND ROD TO GROUND WIRE CONNECTION SHALL <br /> MAT <br /> ACCESS COVER MATERIAL LIST <br /> CARD GRIP © METAL BE ACCESSIBLE THROUGH A H-20 RATED 8"O MINIMUM <br /> COMPOSITE CONTAINMENT CORD GRIP SLOPE CONCRETE ACCESS COVER TO ASSIST INSPECTION, MAINTENANCE <br /> CONTAINMENT ASSEMBLY AND TESTING, THE SCREW TYPE GROUND ROD CLAMP <br /> ELBOW SHOWN �5 EX ELBOW ;.,;;, O 5/8"0 X 10' LONG COPPER CLAD STEEL SHALL BE UL LISTED FOR DIRECT BURIAL. <br /> ROTATED 900 <br /> ASSEMBLY �l` ""I':;I r'"'<' GROUND ROD; GLAVEN INDUSTRIES <br /> 4 ONE STRANDED #8 THHN CONDUCTOR SHALL BE RUN TO <br /> P/N 6260613 or EQUIVILENT <br /> EACH FILL AND VAPOR RISER CLUSTER FROM THE <br /> CONDUCTOR Rg CONDUIT GROUND ROD, THE CONDUCTOR SHALL HAVE 18" <br /> II \ s. F <br /> CORD ® GROUND ROD CLAMP, UL LISTED FOR MINIMUM COVER. THE CONDUCTOR SHALL PENETRATE <br /> GRIP DIRECT BURIAL; THOMAS-BETTS THE SUMP USING A 3/4" PVC COATED CONDUIT AND <br /> CONDUIT / APPROVED <br /> P/N JAB58H or EQUIVILENT BE BENT 9PENETRATION ICONDUIT LL <br /> ` TO THE AND TERMINATE WITH A <br /> CORD GRIP © o CLASSI, DIV It SEAL-OFF FITTING, THREADED ELBOW AND <br /> �_ CONDUIT GROUND LINES TO ® POMECO/OPW 6110-OSWT 8" H-20 RATED CORD GRIP FITTING. A BRONZE PIPE CLAMP SHALL BE <br /> TERMINATE 2" ABOVE —#8 GR UN PENETRATION OTHER SUMPS CONNECTED To THE RISER PIPE To THE BONDING OR <br /> CONDUCTOR CONDUCTOR ACCESS COVER GROUND CONDUCTOR. TO ASSURE A COMPLETE <br /> ABOVE HIGHEST FITTING a .III' CONNECTION, ANY PAINT OR COATING ON THE RISER <br /> PIPE GROUND Ili-iii= L=1 SHALL BE REMOVED PRIOR TO INSTALLATION OF THE <br /> PENETRATION FITTING CLAMP Oa _=1I-_ -n �li 4" NPT ADJUSTABLE BRONZE PIPE CLAMP, <br /> —111— I� I =TTI—I GROUNDCLAMP. <br /> l ITT 1� 1 - - LIND EQUIPMENT P/N JR-150-30 (905) 475-5086 <br /> CRIMPED F <br /> 3/4° PVC COATED — — I_�. —�_ ELECTRICAL CONDUIT, FUELING SYSTEM HARDWARE OR <br /> CONDUIT w/SHORT GROUND LUG n __m. <br /> (BOL'TED TO HOUSING) - =E1 U1 �" ® 3/4" CONDULET ELBOW, CLASS 1 , DIV 1 , THE STATION ELECTRICAL GROUNDING SYSTEM SHALL <br /> n NOT BE USED FOR GROUNDING OR BONDING FILL AND <br /> RADIUS SWEEP NOT TO SCALE TANK R GROUP D, CROUSE-HINDS P/N LBY25 OR VAPOR RISERS. <br /> 3/4" WEAVER NOT TO SCALE EQUIVALENT <br /> PENETRATION <br /> O RISERS INSTALLED ON STEEL SHALL UTILIZE <br /> FITTING GROUND ROD © 3/4" NPT CORD GRIP, CROUSE-HINDS P/N ISOLATION BUSHINGS PER THE MANUFACTURES <br /> SUMP WALL CGB-292, RANGE .1250 TO .250, ZINC STEEL INSTRUCTIONS TO PREVENT CATHODIC CORROSION, <br /> PENETRATION DETAIL ELEVATION VIEW DETAIL <br /> These drawings and specifications are the confidential and .,,,-. ry US _ APPROVALS CALIFORNIA <br /> proprietary property of Shell Oil Products US and shall not be si,eii Oil Products US U U 0 �AF� A U . S.T. TAN STANDARDS <br /> copied, reproduced, disclosed, or used without Shell Oil DISTRICT AREA TECHNICAL <br /> _ <br /> Products US written authorization. They ore intended as --� I� /� I I I� C rr,, /� /n� Cc` C` TANKS A / C` <br /> contract documents for use on this specific project in — ❑ -- U B LEW�LL F B E R G L/1J S /11 V l'\ J <br /> l conjunction with its Issue date and are not suitable for use on —..... Motiva Enterprises LLC NNICAL MANAGER I.- <br /> a different project or at a later date. TERMINAL MANAGER _ GRAPHIC SCALEFU/VAPOR STATIC <br /> TYTIC rLC Po TC T ON <br /> 1 10/31 /02 Clarification/Changes jjR 12700 Northborough Drive SCALE: SAP/WIC # DATE: DRAWN: REQUESTED BY: <br /> © Shell Oil Products US. All Rights Reserved 2002 REV DATE DESCRIPTION OF REVISION BY APP Houston TX 77067-2508 ENGINEER — <br /> NONE 800062 20 AUGUST 2002 RABAGO HOVLAND E01 030600—B <br />