Laserfiche WebLink
%, IED PROGRAM CONSOLIDATED FOIA <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN - (Page I of 2) <br /> 490-1, <br /> FPLANTYPE <br /> N ® 1.NEW PLAN ❑ 2.CHANGE OF INFORMATION <br /> ® 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY.nly) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) 1 <br /> 3. <br /> BUSINESS NAME(Same 2s Facility Name or DBA) Chevron Station#98264 <br /> BUSINESS SITE ADDRESS 1°3- CITY 104. <br /> 3775 Tracy Blvd Tracy, CA 95304 <br /> II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency specified <br /> -by the equipment manufacturers instructions,or annually,.whichever is more frequent.Such work must be performed by qualified personnel[23,CCR§2632_2634,,2634 2641]_ <br /> _.._...... ............. ........... .................. 490.3a. <br /> MONITORING EQUIPMENT IS SERVICED ® 1.ANNUALLY ❑ 99.OTHER(Specify): 4W-3b, <br /> III. MONITORING LOCATIONS <br /> ❑ 1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ❑ 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED [23 CCR§2632.2634] 490.4 <br /> IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) "Che"" <br /> 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) 490.5. <br /> WITH AUDIBLE AND VISUAL ALARMS.[23 CCR 52632,26341 <br /> SECONDARY CONTAINMENT IS: ® a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 49 <br /> PANEL MANUFACTURER: Veeder-Root 490-7. MODEL#: TLS•350 490-8. <br /> LEAK SENSOR MANUFACTURER: Veeder-Root 4990. MODEL#(S): Liquid Sensor Series 794380-419 490-10. <br /> _. ........_ ....... .. ......... ._ ____ _____-__-_ __ ....... <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).[23 CCR§2643] ago-u. <br /> PANEL MANUFACTURER 49x12. MODEL#: 49x13. <br /> IN-TANK PROBE MANUFACTURER: 49x14. MODEL#(S). 49x15, <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS Ll b.DAILY/NIGHTLY LJ c.WEEKLY 490.1& <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 49()-17. <br /> PROGRAMMED TESTS: ❑ a.0.1 g.p.h. ❑ b.0.2 g.p.h. ❑ c.OTHER(Specify): 4 418. <br /> ...._..... _____..__............__. ____ -._._............................................______ __ <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION[23 CM§264x.1] °90.x6. <br /> ...__- ........ ......__ __ _____ .............................______ <br /> El 4.WEEKLY MANUAL TANK GAUGING(MTG)[23 CCR§26467 TESTING PERIOD: E] a 36 HOURS [Ib.60 HOURS 49x21. <br /> 49o-zz. <br /> ❑ -5.-T ANK INTEGRITY TESTING PER[23 CCR§2x43.11 490.23. <br /> __. <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.BIENNIALLY El c.OTHER(Specify): 49x92°6 20' <br /> 49x26- <br /> El 99.OTHER(Specify): __. .-... <br /> 490-2] <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) (Checkall <br /> that <br /> ® 1.CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 490-2e <br /> [13 SECONDARY CONTAINMENT IS: ® a.DRY Elb.LIQUID FILLED ® c.PRESSURIZED [:1d.UNDER VACUUM 4%-29. <br /> PANEL MANUFACTURER:Veeder-Root 490.30. MODEL#: TLS-350 49x31. <br /> LEAK SENSOR MANUFACTURER: Veeder-Root 49x32. MODEL#(S): Liquid Sensor Series 794380-208 490.33_ <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ® a.YES ❑ b.NO 490-34. <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490-31. <br /> - - VU- <br /> __..._.._ .___.._.. .__..____ .-_.__------ ------- ------- <br /> ..__ ______ ___....._ ......O ......OF ........._. <br /> 02.MECHANICAL LINE LEAK DETECTOR(MELD)THAT ROUTINELY PERFORMS 3.0 g p.h LEAK TESTS AND RESTRICTS OR SHUTS OFF 490.36. <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.(23 CCR§26361 <br /> MLLD MANUFACTURER(S): 49 37, MODEL#(S): 490.38. <br /> ® 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS.[23 ccR§26361 490.39. <br /> ELLD MANUFACTURER(S):Veeder-Root 4900- MODEL#(S):PLLD Series 848480-003 49041. <br /> PROGRAMMED IN LINE LEAK TEST: ❑ &MINIMUM MONTHLY 0.2 g.p.h. ❑ b.MINIMUM.ANNUAL 0.1 g.p.h. 490.42_ <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 49043_ <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490 <br /> - <br /> .............------- <br /> [j-4.PIPE INTEGRITY TESTING. 49045. <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(Specify) 49049917 <br /> o,4e. <br /> ❑ 5.VISUAL PIPE MONITORING. 490-4e. <br /> FREQUENCY: ❑ a.DAILY ❑ b.WEEKLY ❑ C.MIN.MONTHLY&EACH TWE SYSTEM OPERATED' 49 19_ <br /> 'Allo ed for monttorint of_nbuned eme pqn -senemtor fuel plpi.g-onyper HSC§2528LSb)(3) _ <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA [23 CCR§M36(a)(3)] 490-50. <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20 CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. 490-51. <br /> _. __............. ._............. ._..... .._.._____... _.. _.__...__._ ....... <br /> ❑ 99.OTHER(Specify) 490-52 <br />