My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_PLAN 1995
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3775
>
2300 - Underground Storage Tank Program
>
PR0231418
>
INSTALL_PLAN 1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:21:56 PM
Creation date
11/6/2018 10:41:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
PLAN 1995
RECORD_ID
PR0231418
PE
2361
FACILITY_ID
FA0003715
FACILITY_NAME
Tracy Blvd Chevron
STREET_NUMBER
3775
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
3775 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\TRACY\3775\PR0231418\INSTALL\INSTALL PLAN 1995.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 2 1 3 4 5 6 1 7 1 8 1 9 1 10 1 11 1 12 13 1 14 1 15 16 1 17 1 18 <br /> LEGEND o o KEY NOTES <br /> --X y(-- -X F:\CPD\84721\LEGEND <br /> 40.00 w N000, 21' 36" W 127.95 T . TOP OF GRATE <br /> DIVISION 2 - SITE WORK <br /> LE. .INVERT ELEVATION <br /> 2.1 (E) WATER 1" METER TO REMAIN. <br /> (N) .NEW 2.2 FEBCO 825 - i" REDUCED PRESSURE BACKFLOW TO CITY STANDARDS <br /> (E) EXISTING <br /> 2.3 FEBCO 765 - 1-1/4" PRESSURE VACUUM BREAKER. <br /> . <br /> 2,4 POINT OF CONNECTION FOR IRRIGFATION SCH 40 PVC - 1-1/4" SIZE. <br /> 1 ® PROVIDE GATE VALVE TO LINE SIZE IN SEPARATE BOX. <br /> .UTILITY POLE 2,5 RECONNECT TO (E) WATER LINE. <br /> L 0WSOFOR <br /> (E) WATER SERVICE 2.6 WATER LINE PROTECT IN PLACE. <br /> 2.7 FOR CONNECTION TO WATER. SEE SHEET L-2. L <br /> CO <br /> .CLEAN OUT 2.8 COPPER AIR LINE FROM COMPRESSOR TO AIR DISPENSER. <br /> ® - 2.9 (E) SEWER LINE. PROTECT IN PLACE. <br /> .CATCH BASIN/TURNING STRUCTURE 210 (N) SCHEDULE 40 PVC IRRIGATION SLEEVE BY GENERAL CONTRACTOR. <br /> SEE SHEET L-2. <br /> A A I U - .UNLEADED PRODUCT LINE <br /> OIVI511'M 11 - EQUIPMENT <br /> COG P PLUS PRODUCT LINE 11,1 (N) AIR/WATER ISLAND. <br /> K � K <br /> _ A S SUPREME PRODUCT LINE DIVISION 13 - SPECIAL CONSTRUCPON <br /> G _ 13.1 (N) FRP UNDERGROUND FUEL STORAGE TANK (TYP. OF 3) <br /> - V VENT LINE 13,2 (N) PRODUCT PUMP (TYP. OF 3) , <br /> 15.4 I 28 _ - _� _ - - VAPOR RETURN LINE 13.3 (N) ANNULAR SPACE MONITOR (TYP. OF 3) <br /> (E) NATURAL 13.4 (N) TLM PROBE, FILL AND STAGE It VENT AND VAPOR RISERS <br /> GAS METER G - SD STORM DRAIN, 54E AS NOTED. 13,5 (N) VENT RISERS TO REPLACE (E) SEE SHEET F-i. <br /> J W z A -. G (E) GAS LINE BE REMOVED. 13,6 (N) WAYNE VISTA 390 MPD (TYP OF 6) <br /> FOLLOW ALL SAFETY <br /> ETY STANDARDS �J <br /> PER PG&E <br /> W 15 - MECHANICAL <br /> '(E) WATER LINE DIVISION- <br /> -'I <br /> ® 0 15.1 (N) PRODUCT PIPING SCHEMATIC ISEE "F" SHEETS FOR I . <br /> INSTALLATION DETAILS. <br /> '(E) SEWER LINE <br /> 15.2 (N) SINGLE WALL VENT PIPING. <br /> SS A (E) 1/2" AIR LINE COPPER TYPE "L" 15.1 (E) CANOPY COLUMN DOWNSPOUTS TO DRAIN ONTO (E) STORM <br /> _ 23 DRAIN SYSTEM. <br /> SS (N) SANITARY SEWER PIPING 15.4 (N) MECHANICAL UNIT. SEE SHEET BM-1, BM-2. <br /> 0 <br /> H ® ® 2 t0 H <br /> _ _ _ ___ C _ _ _ - � ' - 2" SCHEDULE 40 P.V IRRIGATION <br /> __ SLEEVES (STUB OUT 18" INSIDE PLANTER) <br /> i <br /> 0 <br /> CONTACTS <br /> N <br /> POWER\ELEC.\CAS COMPANY TELEPHONE COMPANY <br /> PACIFIC GAS & ELECTRIC PACIFIC BELL O <br /> Q W 55 EAST 10TH STREET 44 W. YOKUTS AVE. <br /> TRACY, CA 95376 STOCKTON. CA 95207 <br /> 2.8 ATTN', BILL BRIDGES ATTN: SYLVIA SIMUNS <br /> I <br /> PHONE: (209) 836-0440 PHONE: (209) 474-4742 I I <br /> WATER COMPANY PUSUC WORKS <br /> SS CITY OF TRACY FINANCE DEPT. CITY OF TRACY PUBLIC 'WORKS <br /> 2 9 325 EAST 10TH STREET 520 TRACY BLVD. <br /> TRACY, CA 95376 TRACY, CA 95376 <br /> ATTN: KAREN SILVA ATTN: MR. ZABIH ZACA <br /> G 'a PHONE, (209) 835-2211 PHONE: (209) 836-4420 <br /> e SEWER FIRE F <br /> P I LE. 14,611 I E. 14.72 E 14.89 E 1506 ( in CITY OF TRACY PUBLIC WORKS CITY OF TRACY FIRE PREVENTION <br /> CO m 520 TRACY BLVD. 325 E. 10TH STREET <br /> _SD 34y4�® .005- SD 34' 4" ® ,005 CO (E) NATURAL 1 TRACY, CA ABIH TRACY, CA 95376 <br /> ROBIS <br /> I ATTN: MR. ZABIH -44 ATTN: BILL 9) 8 36- <br /> ' GAS PIPING PHONE: (209) 836-4420 PHONE: (209) 836-8059 <br /> I NI of I <br /> I _ _ <br /> PIPING NOTES <br /> I <br /> o I 1nI CO i CO I ®I CO 15.1 DIV/SP/DiL5/NOTES/0260NO2C <br /> E a) 50 15'3 ' I I 1. PETROLEUM, SEWER, AIR AND WATER PIPING SHOWN SCHEMATICALLY. CONTRACTOR E <br /> SHALL INSTALL PIPING PER FIELD CONDITIONS WITH CHEVRON REPRESENTATIVE'S <br /> U I VRI U( I APPROVAL <br /> mI I I P I <br /> S ( UI I P I 2. FOR BID PURPOSES ONLY, CONTRACTOR IS TO ASSUME A TANK BURIAL <br /> P N DEPTH OF 7'-0" TO TOP OF TANK. CONTRACTOR TO DETERMINE ACTUAL <br /> LE. 14.86 I IE. 1503 I I I.E. 15.20 ' S I G ELEVATIONS AND GUIDELINES RIORRTOUIRED TANK CONSTRUCTIONRIAL DEPTH WITHIN CUSA <br /> I I I 3 ALL PRODUCT, VENT AND VAPOR RETURN LINES SHALL SLOPE 1/4' PER <br /> Z I CO I CO I CO I FOOT UPWARD FROM TANK (1/8" PER FOOT MIN.) <br /> m oI I I 4 SEE SHEET L-2 FOR IRRIGATION PIPING PLAN, <br /> ®I I f>} 136 I I 5, CONTRACTOR TO PROVIDE SEWER SYSTEM AND STORM DRAIN LINES 'NTH <br /> dp I �I I I fat I I CLEAN-OUTS WHERE REQUIRED BY LOCAL MUNICIPALITY. D <br /> N <br /> 15S 6, STUB UP PVC'. IRRIGATION SLEEVES AND STUB UP & CAP IRRIGATION WATER _ <br /> - - - VR - - - - - - - 13.5 LINES MIN. 121" FROM BACK OF CURB AND MIN. 18" DEEP. <br /> 5 p S P i5.2 <br /> U U 7. SANITARY SEWER PIPING UNDER BUILDINGS (NEW OR REPLACED) AND TO 5' BEYOND <br /> I / \ I -< V BUILDINGS SHIALL BE HUBLESS CAST IRON AND FITTINGS IN ACCORDANCE WITH MARK DATE REVISIONS INIAL <br /> 1 - V IAPMO-IS-6A2. SDR-35-PVC SHALL BE USED UNLESS OTHERWISE NOTED. MIN. <br /> SLOPE ON ALL PIPING IS 1/4" PER FOOT. PIPING <br /> nI`^,: p n' <br /> to SO 13.2 S ! I I P I I I U Iyl W 8, STORM DRAIN PIPING SHALL BE SOR-35-PVC UNLESS OTHERWISE NOTED, YARD 1 II '1 •41 1 LA1 Y <br /> I/ I PROVIDE TWO WAY CLEAN-OUTS AT ALL CANOPY AND OR BUILDING DOWNSPOUTS. <br /> Ln I 9 PLUMBING DESIGN BASED ON 55 TO 65 PSI AT CITYS WATER MAIN, IF <br /> o C 13 a 21 I a / I KI j I DISCREPANCY EXISTS BETWEEN WATER PRESSURE TESTED ON-SITE AND 9_8284 C <br /> ,Jj I v ] VR VR Z VR THAT NOTED ON PLANS, CONTRACTOR SHALL IMMEDIATELY NOTIFY CHEVRON <br /> � I I o 1 REPRESENTATIVE AND ROBERT H. LEE AND ASSOCIATES, INC. 3775TRACYBLVD, <br /> V I I V I G 10, SEE SITE PLAN FOR DETAIL CALLOUTS. TRACY, CA. <br /> p1 131 I I I I ® I 71. SEE SHEET 3P-1 FOR BUILDING PLUMBING. <br /> o I <br /> j I i I 13.4 <br /> TG. 15 50 I S/ Chevron <br /> CO 0 I I (E) 4"� W 2.10 (E) I.E. NORTH Northwest Region - B <br /> LE. 73.73 1„ T.G. 14.75 Il <br /> B ` I.E. 13 83 <br /> I SS <br /> TO G. 115.50 Al - 2.3 G <br /> IE. 13.36 0 ^-} A-3 =-- ---------------- ROBERT H. LEE & ASSOCIATES, INC. <br /> 2 q ARCHIRECTIJRE ENdNEERINCi ENVIRONMENTAL BERVICEB <br /> 2d'b, SD 1137 NORTH McOOWELL BOULEVARD PETALUMA CA. 94954 (707) 765-1660 <br /> F JOHN W. JOHNSON, ARCHITECT JAMES H. RAY, CML ENGINEER <br /> 40.00' --- 00' 21' 36" E 127.95' RHL REVIEW INIAL DATE DATE: 10JUL95 <br /> LE. 13 36 SD PRELIMINARY <br /> d SO 2.1 (E) STORM DRAIN <br /> < -- (E) STORM DRAIN Al 01 22 LINE. CONNECT TO i 0 5 10 20 30 40 PLANNING OR, BY. N�"C <br /> y LINE. CONNECT TO Aq A-1 (N) CATCH BASIN STEEL 81D <br /> .� (N) TURNING STRUCTURE. APPR. <br /> 00 BLDG PERMIT <br /> Z A GENERAL 610 RHL 8740.10 <br /> PERMIT REVS A <br /> u SHEET <br /> TRACY BOULEVARD 9 <br /> Q CONSTRUCTION <br /> for col n r oleo w n P-1 <br /> SCALE' 7"=10'-0 uN construction <br /> a <br /> 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.