My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_PLAN 1995
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3775
>
2300 - Underground Storage Tank Program
>
PR0231418
>
INSTALL_PLAN 1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:21:56 PM
Creation date
11/6/2018 10:41:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
PLAN 1995
RECORD_ID
PR0231418
PE
2361
FACILITY_ID
FA0003715
FACILITY_NAME
Tracy Blvd Chevron
STREET_NUMBER
3775
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
3775 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\TRACY\3775\PR0231418\INSTALL\INSTALL PLAN 1995.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 2 3 4 5 6 7 8 9 10 n 12 1 13 1 14 1 15 16 T7 19 <br /> I <br /> NOTE: CONTRACTOR TO FIELD VERIFY DISPNSER BASF DIMENSIONS. M <br /> M FFILTER <br /> PENSER <br /> E%PLOSION PROOF JUNCTION BO% 4$" <br /> YD $CH. 40 BIACN IRONSEAL OFF 24" 24E(RISER 21" 21" <br /> 1 1/2" N.P.T, INLET UNION PIPE CAP WITH HOLE FOR CONTAINMENT PROBE WIRE 91. 10 172 1 10 172 v 9 <br /> (BY DISPENSER MFG.) <br /> FILTER CHANGE TRIP TRAY SEAL ALL OPENINGS WATER TIGHT 14 2 172" <br /> 374 16" <br /> (BY DISPENSER MFG.) 3/4" x 1 1/2' SLOTS (8) —1/2' N.P.T. CONDUIT (SPEAKER OPTIONAL) <br /> OPW DUAL POPPET,BOSS MOUNT — SLOPE CONCRETE 1 1/7 PER FOOT AWAY FROM DISPENSER (TYP.) PROVIDED FOR ANCHOR BOLTS <br /> I1 L <br /> L IMPACT VALVE _ <br /> (SHEAR SECTION TO BE FLUSH _ <br /> WITH TOP OF DISPENSER ISLANO) r ' <br /> M r� <br /> • n _ <br /> • • OUTLET T, VAPOR RECOVERY -1 I 2 4' - n o <br /> 3/4' P.V.C. PUMP OUT PIPE <br /> WITH THREADED FITTING STABILIZER BAR <br /> SUMP PENETRATION BOOT FOR CONDUIT 4 1 4� iv <br /> F.R.P. DISPENSER CONTAINMENT BOX `0 <br /> 45' BLACK IRON ELBOW 3/4" CONDUIT TO CONTROL PANEL (POWER) - [7j= - -- - -- - - <br /> K 3/4" CONDUIT TO CONTROL PANEL (DATA) <br /> `I I -41 <br /> K <br /> 0 0 <br /> o — — — — — — — — - 3/4" CONDUIT TO CONTROL PANEL (SPEAKER) <br /> I 3. 3. <br /> — — — 3/4- CONDUIT FOR CONTAINMENT BOX PROBE <br /> 10" f" N.P.T. VAPOR RECOVERY OUTLET <br /> c � TO CEI 3000 PANEL <br /> 0 2 1/2" MINIMUM CLEARANCE I 1' P.V.C, PIPE OPEN AT BOTTOM. <br /> —1 1/2" N In T INLET (3) <br /> BETWEEN FITTING & PIPE r" , ATTACH TO CONTAINMENT BOX AS NEEDED FOR SUPPORT. I' N.P.T. CONDUIT <br /> /(1 2"0 F.R.P. PIPE ( L �( - _API/RONAN LS-3 CONTAINMENT BOX_ PRQBE`i' THE PHASE It VAPOR RECOVERY LINE MAY BE PLUMBED TO EITHER OF THE I" N.P VAPOR RECOVERY OUTLETS. <br /> FIELD VERIFY THAT THE DISPENSERS ALUMINUM MAINIFOLO IS INSTALLED HORIZONTAL OR SLOPED TOWARD <br /> J 3"0 F.R.P. PIPE 1 1/2"M SWIVEL x 2"F 24" FLEXIBLE CONNECTOR THE VAPOR OUTLET USED. J <br /> 6 1 2" 6 1 2" PENETRATION D001 USE APPROVED NON-HARDENING JOINT COMPOUND <br /> MINIMUM MINIMUM WI TO 2- REDUCER BOOT II, <br /> FOR THREADED CONNECTIONS 2 DISPENSER BASE - DRESSER WAYNE V300 <br /> CLEARANCE CLEARANCE WITH' TEST PORT r� 2" BELL & MALE F.R.P. THREADED ADAPTOR <br /> BETWEEN BETWEENSCALE 7 1/2--l'-9 <br /> PIPE PIPE <br /> PRODUCT 48"0 F.R P. CONTAINMENT SUMP 48"0 F R.P. CONTAINMENT SUM <br /> H <br /> HJB" MULTIPORT MANHOLE 36" MULTIPORT MANHOLE <br /> NOTE: FIBERGLASS THE HAND HOLE LID TO THE DISPENSER CONTAINMENT BOX TO INSURE A WATER TIGHT SEAL, 22" FUEL TANK MANWAY <br /> PENETRATION BOOT PENETRATION BOOT <br /> DISPENSER -- " <br /> GENERAL CONTRACTOR TO PROVIDE <br /> 3' EL GALVANIZED <br /> RIGID PIPING TO EACH VAPOR RECOVERY <br /> MANIFOLD - 2" F.R.P. VENT LINE Y F.R.P, VAPOR LINE STEEL ELBOW <br /> Q <br /> Q 1 1/2" x V OPW DUAL POPPET <br /> VAPOR SHUTOFF VALVE <br /> (SHEAR SECTION TO BE FLUSH <br /> WITH TOP OF DISPENSER ISLAND) - Y BELLrMALE F.R.P, THREADED ADAPTOR +• <br /> THREADED ADAPTO <br /> MOUNT VAPOR SHUTOFF VALVE <br /> USING PHIL-TITE VAPOR IMPACT x 18" FLEXIBLE 3" x 17 FLEXIBLE <br /> CONNECTOR <br /> CONNECTOR <br /> VALVE SUPPORT KIT. - MALE SWIVELxFEMALE <br /> If 3' STEEL UNION <br /> ' ♦ OF TANK - OF TANK <br /> • PENETRATIONBOOT \ ' F <br /> P 45' BLACK IRON ELBOW -- Y F.R.P, VAPOR LINE ` 7 F.R.P. VENT LINE \ <br /> 2" BELLXMALE F.R.P, PENETRATION \ <br /> 6" MINIMUM PEA GRAVEL <br /> COVER OVER F,R.P. PIPE THREADED ADAPTOR ROOT <br /> Y x 19' FLEXIBLE Y BELbMALE F.R.P. <br /> CONNECTOR THREADED ADAPTOR <br /> MALE $WIVELxFEMALE <br /> Y x 16' FLEXIBLE <br /> 1�tI/�2"M SWIVEL x 3"F 24" FLE%19LE CONNECTOR DPW 233VM-4422 MALE CONNECTOR OPW 233VM-60a5 <br /> Wr ELxFEMALE <br /> USE APPROVED NON-HARDENING JOINT COMPOUND EXTRACTOR FITTING EXTRACTOR FITTING <br /> E FOR THREADED CONNECTIONS. E <br /> Y0 F.R.P. VAPOR RECOVERY PIPE GALVANIZED 2' 90' GALVANIZED <br /> Y SELL x MALE FRP. THREADED ADAPTOR STEEL <br /> ELBOW <br /> $TEFL ELBOW <br /> PENETRATION BOOT h � PLUS Re SUPREME UNLEADED TANKS REGULAR UNLEADED "DROP OUT" TANK <br /> NOTE: STEEL RISERS MUST BE 16" O.C. TRUE <br /> < AND PLUMB. USE• THE PHIL-TITE FILL-VAPOR <br /> VAPOR RECOVERY RISER SUPPORT BRACKET # 1600. <br /> NOTE: FIBERGLASS THE HAND HOLE LID 10 THE DISPENSER CONTAINMENT BOX TO INSURE A WATER TIGHT SEAL. <br /> Q FILL. TLM. VAPOR & VENT PLAN <br /> D <br /> �D <br /> SCALE: 111=1'-0° <br /> DISPENSER CONTAINMENT & PIPING NOTES: DISPENSER INSTALLATION AND <br /> AL1. OMIT. TANK FILL/VAPOR CONTAINMENT <br /> aO 2. ALL PRODUCT LINES ARE TO BE SECONDARILY CONTAINED <br /> 6i C 3. EVERY TANK CONTAINMENT SUMP AND DISPENSER CONTAINMENT SUMP SHALL CONTAIN -8264 C <br /> O A LIQUID SENSING PROBE, 377'5FpTRACY OLVD. <br /> rn 4. CAULK THE BOTTOM OF THE DISPENSERS TO INSURE WATER TIGHTNESS. 3775TRACY, CA. <br /> _rn {{11 <br /> ✓1 5 PS OTIHE MAXI}AUM TAALLLOWABLEEPENETRATION FTHE "ANGLESUMPS ARE PREFERRED <br /> 20' <br /> O <br /> d 6. SPARE ELECTRICAL CONDUITS MUST BE SEALED. <br /> 7, SEE SHEET E-1 FOR ELECTRICAL CONDUIT LAYOUT wo <br /> Chevron- <br /> 8 <br /> , OBTAIN WRITTEN APPROVAL FROM CHEVRON FOR LESS THAN 1/4" PER FOOT Northwest Region g <br /> SLOPE ON PRODUCT, VAPOR AND VENT LINES. <br /> B <br /> 9. ALL STEEL TANK RISERS O FILL END ARE TO BE SCH. 40 GALVANIZED PIPE <br /> PRIME AND WRAP ALL STEEL PIPING AND RISERS, ROBERT H. LEE & A880CIATES, INC. <br /> 10. ALL STEEL DISPENSER PIPING AND FITTINGS ARE TO BE SCH. 40 BLACK IRON. AFI FWFECTUFiE ENONEERNO ENVWONMENT'AL BB F_8 <br /> PRIME ALL BLACK IRON FITTINGS. PRIME AND WRAP STEEL PIPING AND RISERS. 1137 NORTH MCDOWELL BOULEVARD PETALUMA CA. 94954 (707) 765-1660 <br /> JOHN W. JOHNSON, ARCHITECT JAMES H, RAY, CIVIL ENGINEER <br /> 11. USE ALL SCH. 40 BLACK IRON PIPING AND FITTINGS FOR DIESEL INSTALLATIONS. RI REVIEW INmAL DATE DATE: <br /> PRIME AND WRAP ALL STEEL PIPING AND RISERS, <br /> PRELIMINARY <br /> PLANNING OR. BY: <br /> STEEL BID <br /> APPR.: <br /> BLDG PERMITA <br /> O <br /> A GENERAL BID RHL 08740"10 <br /> Z <br /> PERMIT REVS <br /> SHEET <br /> 0 CONSTRUCTION <br /> ZDo not use drawing <br /> N far construction F <br /> Q <br /> unless initialed <br /> 0 <br /> 1 2 3 4 5 6 7 6 9 10 11 12 13 14 15 16 17 16 <br />
The URL can be used to link to this page
Your browser does not support the video tag.