My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 1985-1992
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3788
>
2300 - Underground Storage Tank Program
>
PR0503876
>
BILLING 1985-1992
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2024 4:30:09 PM
Creation date
11/6/2018 10:47:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
1985-1992
RECORD_ID
PR0503876
PE
2381
FACILITY_ID
FA0006002
FACILITY_NAME
UNION OIL #6348
STREET_NUMBER
3788
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21225002
CURRENT_STATUS
02
SITE_LOCATION
3788 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\TRACY\3788\PR0503876\BILLING 1985-1992.PDF
QuestysFileName
BILLING 1985-1992
QuestysRecordDate
8/17/2017 11:26:34 PM
QuestysRecordID
3589898
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFOR10 WATER RESOURCES CONT BOARD Q FORM V: UN ERGROUND STORAGE TANK PR GRAM <br /> TANK (/ TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING FORMATION FOR EACH TANK. <br /> MARK ONLY ❑ I NEW PERMIT ❑3 RENEWALPERMIT5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSE <br /> ,�1 <br /> ONE ITEM ❑2 INTERIM PERMIT F-] 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑B TANK REMOVED / <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: �j-7 Cti FARM TANK-YES❑ NO ��❑ <br /> I. TANK DESCRIPTION COMPLE EALL ITEMS-IF UNKNOWN-SO SPECI �( <br /> A. OWNERS TANK ID X ) ,i B. MANUFACTURED BY: <br /> C. YEAR I ALLED 1 N//` O. TANK CAPACITY IN GALLONS: <br /> C <br /> II. TAN CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. CT <br /> A. tn 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. ��/. C. ❑ 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> F-13 CHEMICAL PRODUCT ❑ 4 OIL El}PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> El HAZARDOUS ❑ 80 EMPTY E]95 UNKNOWN 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> 0. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OFS <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.R C A.S.N: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A TYPE OF ❑ 1 DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR UNER ❑ 95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> ❑ 1 STEEL/IRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑ 4 STEEL CLAD WIF18EAGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑6 POLYVINYLCHLORIDE F-17 ALUMINUM ❑ 8 188%METHANOL COMPATIBLE FAP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑ 99 OTHER <br /> ❑ I RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑4 PHENOLIC UNING <br /> LINING ❑ ❑ <br /> C. INTERIOR 5 GLASS UNING 6 UNLINED 95 UNKNOWN❑ <br /> ❑ ISUNING MATERIAL COMPATIBLE WITH 180%METHANOL? ❑YES ❑NO ❑ 99 OTHER <br /> D. CORROSION ❑ I POLYETHLENE WRAP ❑2 TAR OR ASPHALT ❑3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑91 NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U I SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> 8. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEELCLAD W/FRP A U 8 100 METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P 8 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> P 8 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 6 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY N JURISDICTION N AGENCY A FACILITY ID MTANK ID A <br /> = , l h Pid- 101T <br /> CURRENT LOCAL AGENCY FACILITY JD II 1 APPROVED BY NAME PHONE M WITH AREA CODE <br /> PERMIT NUMBERIl/J PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK 8 PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT 0 BY: <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.