My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_PLAN 1997
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3940
>
2300 - Underground Storage Tank Program
>
PR0507837
>
INSTALL_PLAN 1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:54:36 PM
Creation date
11/6/2018 10:49:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
PLAN 1997
RECORD_ID
PR0507837
PE
2361
FACILITY_ID
FA0008057
FACILITY_NAME
TRACY TRUCK AND AUTO STOP
STREET_NUMBER
3940
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95304
APN
21220004
CURRENT_STATUS
01
SITE_LOCATION
3940 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\TRACY\3940\PR0507837\INSTALL\INSTALL PLAN 1997.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> - -- <br /> Aa <br /> N <br /> r- --------------------------•-------- ----- - --- ---- -------------------- - ------ - :..-- <br /> I ' <br /> I <br /> I PR®Z(LV FOR <br /> 04 BARS, 6.-S.. MIN., I ,'•� <br /> 4" O.G. TYPICAL I CHn NJ .q. NUL <br /> L% <br /> . - TANK GAUGE MANHOLEHX- <br /> - <br /> FRENONT� ca <br /> 96539 <br /> vI INM <br /> ANNULAR SPACE <br /> PROBE MANHOLE <br /> j 36" MANWAY, BEGINNING OF CROWN <br /> i o <br /> PRODUCT FILL MANHOLE <br /> - <br /> TYPICALTED' MIN. CROWN SLAB TO 1" AT MANWAYB G �7 <br /> 5811 W. LARCH RD. <br /> - - �vr <br /> . I --- ---------------------------- <br /> ---------- <br /> ------------------------- - 4r�° A� Up CA <br /> L— _------ ----._ - qJ <br /> (3-9307 <br /> G°QPb 292.200-0,6 <br /> REINFORCED CONCRETE _ <br /> SLAB W/ "4 REBAR + IS" O.C. <br /> BOTH WAYS (FIELD BARS NOT SHOWN) ALTON <br /> TYP. TANK - PARTIAL SLAB PLAN NGINEERING, INC. <br /> SCALE: <br /> TANK GAUGE P.O. MOX 1025 <br /> CAP KIT, TYP. 843 RISKE LANE <br /> IS" W.T.MANWAY WEST SACRAMENTO, CA 95691 <br /> FOR TANK GAUGE 5 GAL. (MIN.) FILL CONTAINMENT -(916) 12. 1888 ? <br /> MANHOLE W/ FILL CAP - FAX 1 .1"12 - <br /> "4 REBAR TO BE PLACED 36" MANHOLE, H-10 RATED, MIN. <br /> CROWN SLAB 4 TOP SEAL ADAPTOR, TYP. - <br /> AROUND MANHOLES (TYP.) SUBMERGED TURBINE PUMP + 2" TYP. B REINFORCED GONG. <br /> MANIFOLD ASSEMBLY I I 1Y" TYP. SLAB W/ 04 REBAR + iS"m WATERTIGHT ruE6E aRawrt�a elc roNe,AS i <br /> 41"o X 32' 0 FIBERGLASS W/ LEAK DETECTOR EXPLOSION PROOF "J" "(`� 18" O.C. BOTH WAYS MANHOLE NVIRkIEROFERTY OF OF � RE wile <br /> CONTAINMENT SUMP W/ LID, TYP. BOX W/ SEAL-OFFS, TYP. P TYP. TMnj.�°F�p 'p <br /> v - - 9EtT18Ai`KI D CR P!}�0 THEA€ DRAWWA <br /> -.•-.� .-..-• — - 4- : <br /> 6441.NOT BB RE�CED, <br /> n n a_ `.•_,• P =� a /.. ,• .< •� =•-';J• ••-• r. HpUr 1HE BB 11'= <br /> Po IE I OR TRACED <br /> T OF <br /> T <br /> -_ CONDUIT TO PUMP RELAY II I_I 1 I III 11 k I WAI. I MER '. <br /> � i <br /> 11i COPYRIGWT © '1997 <br /> F.R.P. VENT LINE. .. .. II -I !' I t _ .. , <br /> ' i II' I <br /> TYP. SLOPE A MIN. OF I/e' ER - I 4�i c - . <br /> BALL VALVE- FT. BACK TO TANK, Y - ! '•- DRAUId $Y MEL / TG <br /> SUMP MONITOR 4"m BLACK IRON <br /> FIBERGLASS PRODUCT LINE— _ RISERS (TYP.) —� I �- CNKD! BY MEL <br /> '1 W/ SECONDARY CONTAINMENT HOUSING W! LIQUID DBL PVC WRAP - "m RISER <br /> — i <br /> — i '- <br /> S/SEALa PROBE ALL Ula. METAL - DATE. -12 DEC 9'1 <br /> ArrACNED SUM COLLAR PLUG/SEAL UNUSED <br /> I <br /> — MANUFACTURER � . <br /> BUNGS, TYPICAL <br /> P <br /> -BY rANK MANUFA SCALE I/2" a 1'-O" <br /> i I li—i it _ FI III PRODUCT LINE - I— !_ ------ <br /> vENT EXTRACTOR I JOp NO. 4360 <br /> i—I — <br /> ASSEMBLY W) SWING W/ SECONDARY CONTAINMENT - <br /> = II <br /> FI RCsLA55 PIPE. SLOPE PIPE <br /> JOINT OR FLEX A IN. OF 1/8" PER FOOT BACK - - I_� <br /> CONNECTOR W/ T THE TANK SUMP, TYP. -1 <br /> IF FILTER FABRIC REQUIRED: SWIVEL, TYP. REVISIONS <br /> INSTALL FILTER FABRIC LINING OVERFILL 12' MIN. (TYP) -ON THE BOTTOM AND ALL PREVENTION VALVE, ' DATE REV DESCRIPTION 5 <br /> 51DES OF WALL$ W/ V-0" = TYPICAL 2' <br /> OVERLAP AT TOP EXCAVATION. TYP. 11 - I <br /> IN WET-HOLE APPLICATIONS <br /> PUMP EXCAVATION DRY PRIOR p_y" <br /> 20$000 GA ON DIESEL - <br /> TO INSTALLATION. <br /> I <br /> MAGNETOSTRICTIYE -- - - <br /> TANK GAUGE �i <br /> CENTER GAUGE/BUNG <br /> AT TANK CENTER - <br /> _ 45' FIELD GUT NATIVE SOIL (TYP) •Y TITLE C <br /> SLOPE TANK TOWARDS t SNEI; 1 1 111..E <br /> 1— ANNULAR SPACE PROBE TANK STRIKER PLATE BY TANK ------ <br /> i_i— <br /> MANUFACTURER (TYP.) UNDER I <br /> _ ! - o� ALL TANK OPENINGS. I ANNULAR SPAGE <br /> — PROBE - <br /> TANK <br /> =ill I � 1 = SECTION <br /> .. PEA.GRAVEL BACKFILL (TYPd kL� <br /> W41# <br /> _ SLAB <br /> i:' - I 12" MIN (TYP) <br /> _ _ I <br /> ;Ili � � �-11r III-� 11_ � DIESEL TANK SECTION - 20,000. DBL. 4�/ ALL !_ , 11 ,Iir, � - <br /> CI I I I I_jil- <br /> t -- <br /> i <br /> OF 10 SWEEPS <br /> l <br />
The URL can be used to link to this page
Your browser does not support the video tag.