Laserfiche WebLink
STATE OF CALIFORNIA ^f�ao• ,. <br /> STATE WATER RESOURCES CONTROL BOARD $ <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION• FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT O CHANGE OF INFORMATION <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 7 PERMANENT p <br /> e TEMPORARY TANK CLOSURE ❑ B TANK REM V D <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS— SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK 1.D.# B. MANUFACTURED BV: / <br /> C. DATE INSTALLED(MO/DAY/YEAR) t� ,/...I D. TANK CAPACITY IN GALLONS: <br /> 6 7 <br /> II.TANK CO S IFA-1 IS MARKED,COMPLETE ITEM C. <br /> A. MOTOR VEHICLE FUEL ❑ 4 OIL g, aREGULAR <br /> - ❑ 2 PETROLEUM ❑ 80 EMPTY 7 PRODUCT C lbPREMIUM 3 DIESEL ❑ g AVIATIONGAS <br /> 4 GASAHOL ❑ <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN 2 WASTE ❑ UNLEADED ❑ 5 JETFUEL 7 METHANOL <br /> ❑ ❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED <br /> C.A.S.# <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B,AND C.AND ALL THAT APPLIES IN BOX D AND <br /> A. TYPE OF ❑ '�LE WALL ❑ LINER E]3 SINGLE WALL WITH EXTERIOR LI <br /> ❑/ 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS <br /> ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ e NN L CHLORIDE ❑ 7 ALUMINUM ❑ B 100% METHANOL COMPATIBLE W/FRP <br /> (PrimaryTank) ❑ g BRONZE 10 GALVANIZED STEEL NKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 AWM LINING <br /> C.INTERIOR 1:13 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING ❑ 5 GLASS LINING6 UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IS LINING MATERIAL COMPATIBLE WITH 100. METHANOL? YES_ NO_ <br /> O.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP <br /> ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE UNKNOWN <br /> ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) <br /> OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION CIRCLE A IFABOVEGFLIVDOR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U PRESSURE A U 3 GRAVITY <br /> A U 99 OTHER <br /> B. CONSTRUCTION SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH <br /> A U 95 UNKNOWN p U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A42�4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEELW/COATING <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODICPR CTION 9 UNKNOWN A U B 1009' METHANOL COMPATIBLE W/FRP <br /> D. A U 99 OTHER <br /> LEAK DETECTION AUTOMATIC LINE LEAK DETECTOR 3 <br /> LINE TIGHTNESS TESTING MONgORING ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK 2 INVENTORY RECONCILIATION [E:13 VADOZE MONITORING 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> [-] 6 TANK TESTING [:] 7 INTERSTITIAL MONITORING ❑ 91 NONE <br /> ❑ 95 UNKNOWN ❑ 98 OTHEq <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MOIDAY/YR) 2.ESTIMATED QUANTITY OF <br /> SUBSTANCE REMAINING3.WAS TANK FILLED WITH <br /> GALLONS INERT MATERIAL? YES ❑ NO ❑ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY. P UR ND TOT T OF <br /> APPLICANTS NAME MY KNOWLEDGE, IS TRUE AND CORRECT <br /> (PRINTED 8 SIGNATORE) DATE <br /> g'2-9s� <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> STATE I.D.# <br /> COUNTY# JURISDICTION# FACILITY# TANK# 001 <br /> m <br /> PERMIT NUMBER I I <br /> PERMIT APPROVED BV/DATE 1PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION•FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FORM B'(72-91) FILE THIS FORM WITr LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STJLAGE TANK RF�GUULAyTIONS <br /> in„ l 0- FORKN&' <br />