My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
110
>
2300 - Underground Storage Tank Program
>
PR0502501
>
BILLING
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2020 11:28:00 PM
Creation date
11/6/2018 11:08:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
RECORD_ID
PR0502501
PE
2381
FACILITY_ID
FA0004053
FACILITY_NAME
LUSTRE-CAL NAME PLATE CO
STREET_NUMBER
110
Direction
E
STREET_NAME
TURNER
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04124048
CURRENT_STATUS
02
SITE_LOCATION
110 E TURNER RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\T\TURNER\110\PR0502501\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
9/2/2016 6:53:18 PM
QuestysRecordID
3182795
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
------------- <br /> STATE OF CALIFORNI WATER RESOURCESCONTRf 30ARD ; `` <br /> UNDERGROUND STORAGE TANK PROMAM � <br /> FORM `B': TANK PERMIT APPLICATION INFORMATION Z <br /> TANK COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. N 1 O <br /> 5 CHANGE OF INFORMATION ❑7 PERMANENTLY CLOSED TANK <br /> ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑8 TANK REMOVED ' t w <br /> MARK ONLY ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE <br /> ONE EM ❑ 21NTERIM PERMIT FARMTANK-YES❑ NO N <br /> 10 In A <br /> CD <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: (A <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SBE MANUFACTURED BY <br /> FY <br /> A. OWNERS TANK IDN D. TANK CAPACITY IN GALLONS'. <br /> C. YEAR INSTALLED <br /> 11. TANK CONTENTS IF(A.1),15 MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM ❑ 3 DIESEL <br /> B C. E] E] 2 1 UNLEADED 2 LEADED <br /> A. E] 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM ❑❑ 1 PRODUCT <br /> 4 GASAHOL ❑5 JET FUEL ❑6 AVIATION GAS <br /> 113 CHEMICAL PRODUCT [:] 4 OIL 7 METHANOL OTHER(DESCRIBE IN ITEM D,BELOW) <br /> 5 HAZARDOUS ❑80 EMPTY E]95 UNKNOWN Q WASTE 11J <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF � C.A.S.N' <br /> HAZARDOUS SUBSTANCE STORED&CA S,N <br /> 111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D 95 UNKNOWN <br /> A.TYPE OF ❑ 1 DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER <br /> SYSTEM ❑ <br /> 2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> I STEEL/IRON ❑2 STAINLESS STEEL ❑ 3 FIBERGLASS 4 STEEL CLAD WIFIBERGLASS REINFORCED PLASTIC <br /> F-] <br /> B.TANK ❑ 5 CONCRETE ❑6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM <br /> ❑B 100%METHANOL COMPATIBLE FRP <br /> MATERIAL ❑9 BRONZE ❑ 10 GALVANIZED STEEL 5 UNKNOWN ❑99 OTHER <br /> ❑ I RUBBER LINED ❑2 ALKYD LINING ❑ 3 EPDXY LINING ❑4 PHENOLIC LINING <br /> C.INTERIOR ❑ 5 GLASS LINING ❑6 UNLINED ffin UNKNOWN to <br /> LINING <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO HER <br /> D.CORROSION ❑ 1 POLYETHLENEWRAP F-12 TAR OR ASPHALT ❑3 VINYLWRAP F-14 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE5 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE U UNKNOWN A U 99 OTHER <br /> A <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 5 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL U UNK<OWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VACOSE WELLS S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE 8 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? YES ❑NO <br /> THIS FO AS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 6 SIGNATURE) DATE <br /> LOCAL AGENCY <br /> I�USE <br /> I�ONLY <br /> -�I <br /> CON JURISDICTION#L- -U--�-�J AGE FACILITY ID k TANK IDD <br /> (� a 3 cp U <br /> CURRENT LOCAL AGENCY FACILITY IDN APPROVED YNAME PHONE N WITH AREA CODE <br /> 0 <br /> PERMIT NUMBER PERMITA#'PIIOVAL DATE PERMIT EXPIRATION DATE <br /> CNECKN <br /> "RUM AMOUNT SURCHARGEAMT. FEE CODE RECEIPT# BY: <br /> FORM B(6-29-88) THIS FORM MUST BE ACCONPA BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS..I FORM W HAS BEEN FILED <br /> DATA-P$QCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.